Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 23, 2021 SAM #7174
SPECIAL NOTICE

63 -- Installation of Additional ResidentGuard System Coatesville VA Medical Center Intent to Sole Source

Notice Date
7/21/2021 4:29:39 AM
 
Notice Type
Special Notice
 
NAICS
541519 — Other Computer Related Services
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24421Q0767
 
Archive Date
08/20/2021
 
Point of Contact
Daniel Johnson, Contract Specialist:, Phone: 717-272-6621x4966
 
E-Mail Address
daniel.johnson44@va.gov
(daniel.johnson44@va.gov)
 
Awardee
null
 
Description
NOTICE OF INTENT TO SOLE SOURCE: The Department of Veterans Affairs Network Contracting Office 4, 1700 South Lincoln Avenue, Lebanon, PA 17042, intends to award a sole Firm-Fixed Price Contract to Accutech Security, LLC. for the provisions of additional ResidentGuard products and services. This contract action is for services for which the Government intends to solicit from only one source under the authority of FAR 6.302-1 and 8.405-6(a)(1)(i)(B). Interested parties may identify their interest and capability to respond to the requirement or submit proposals. The North American Industry Classification System (NAICS) for this requirement is 541519 with a small business size standard of $30 million. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTATIONS. Responsible sources may identify their interest by submitting capability information by 12:00 P.M., EST, on Monday, July 26, 2021, in order to establish sources that meet this requirement. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Daniel Johnson, Contract Specialist, at daniel.johnson44@va.gov. Telephone inquiries will not be accepted. STATEMENT OF WORK 1. Contract Title. Installation of Additional ResidentGuard in Geriatric and Extended Care Units. 2. Background. The Coatesville VA Medical Center (VAMC) has Geriatric and Extended Care (GEC) units that have mobile patients. The Coatesville VAMC would like to ensure the safety of these patients by providing a system that alerts nursing staff of patients trying to leave the unit. The Coatesville VAMC currently has the ES2200 ResidentGuard system by Accutech on several of the GEC units. Expansion of the system is requested to incorporate additional doors. 3. Scope. Contractor is to provide, install and verify proper operation of the ResidentGuard system on the designated GEC units. 4. Specific Tasks. The contractor shall provide, install, and verify proper operation of the following equipment: Building 138E Hospice Unit (1 single doors) One (1) 4 Internal Single Door Kit including door controller, TX wand, keypad, cable kit & door contact One (1) 6 -8 Internal Double Door Kit including door controller, TX wand (2), keypad, cable kit & door contact (2) One (1) KP103 Keypad Two (2) Local Alarm w/Back Box One (1) KP403 Outdoor Keypad Two (2) Magnetic Lock, 3101 Series, NFPA 101 Delayed Egress Two (2) Receiver Mount, Short Lexan 22/12, Non-Shielded Cable Building 138A Patio Entrance (one double door) One (1) 6 -8 Internal Double Door Kit including door controller, TX wand (2), keypad, cable kit & door contact (2) One (1) Local Alarm w/Back Box One (1) KP103 Keypad One (1) Panduit Double Door Kit Two (2) Receiver Mount, Short Lexan 22/12, Non-Shielded Cable The respective equipment listed for 138A must communicate with the current ES2200 ResidentGuard systems installed on 138B. The respective equipment listed for 138E must communicate with the current ES2200 ResidentGuard systems installed on 138E. The contractor shall set up and install each device as needed in order to communicate with the ResidentGuard system. The equipment shall function using the current Accutech sensors worn by the patients. The contractor shall acquire a penetration permit from the Coatesville VA Fire Department when penetrations are required. All penetrations made by the contractor must be sealed with Hilti fire caulk before moving on to the next location. The contractor shall provide a standard one-year warranty on all equipment listed above. 5. Performance Monitoring The contractor shall keep the COR informed of work complete each day. The COR shall randomly inspect the work in progress. 6. Security Requirements. All contractor representatives who perform this work shall acquire the appropriate VAHCS identification badges. No other special security requirements are anticipated. Biomedical Engineering staff must be present for any work performed within Information Technology Communication closets. Contractor shall be working in an area where patient care takes place with potential for incidental exposure to patient information. Contractor shall not disclose any patient information. 7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). There is no GFE or GFI anticipated with this contract. 8. Other Pertinent Information or Special Considerations. a. Identification of Possible Follow-on Work. There is no follow-on work anticipated. b. Identification of Potential Conflicts of Interest (COI). None identified. c. Identification of Non-Disclosure Requirements. Contractor shall be working in an area where patient care takes place with potential for incidental exposure to patient information. Contractor shall not disclose any patient information. d. Packaging, Packing and Shipping Instructions. There are no special requirements. e. Inspection and Acceptance Criteria. Functionality of the installed ResidentGuard system will be verified by Biomedical Engineering. 9. Risk Control. Contractor is responsible for providing all applicable training and protective equipment to protect Contractor s employees from any hazards, including blood borne pathogens, which may be encountered in the performance of this contract. 10. Place of Performance. All work will be performed at the VA Medical Center, 1400 Blackhorse Hill Road, Coatesville, PA, 19320. 11. Period of Performance. Contractor will have 120 days from contract award to complete the installation. 12. Delivery Schedule. Contractor will set delivery schedule to ensure that installation can be completed within 120 days from contract award.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/12df40c4d82e45cd8c149c2abec32a08/view)
 
Record
SN06068326-F 20210723/210721230125 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.