SOLICITATION NOTICE
65 -- Steris model 5095 Surgical Table
- Notice Date
- 7/21/2021 11:49:01 AM
- Notice Type
- Presolicitation
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24621Q1020
- Response Due
- 7/26/2021 10:00:00 AM
- Archive Date
- 08/05/2021
- Point of Contact
- John P Harmsen, Contract Specialist, Phone: 757-315-3978
- E-Mail Address
-
john.harmsen@va.gov
(john.harmsen@va.gov)
- Awardee
- null
- Description
- This is a brand name only Looking for Steris Model 5095 surgical table. The table must be able to accommodate all types of surgical procedures and be put in many different positions. Must have return to level button to reposition the patient while have auto-limit sensors to prevent table damage from colliding sections and inform the operator of alternative table articulation. Must have a removable leg section without no protruding pins to provide unrestricted perineal access. Must have self-leveling floor locks for stability on uneven floors. Must have integrated back up control system in the event of power failure. Must have unique table pad attachment pins (mushroom caps) for easy cleaning and NO VELCRO brand fasteners. Must have a shortened base to increase surgical access for patient positioning, particularly in lithotomy positioning. Must have large clinical work area of relevant image area 83 total body imaging window. Must have 4 sections motorized table-top with powered radiolucent kidney elevator Must have flush side rails absence of exposed screws. Must have patient weight capacity up to 1200lbs to include raise/lower (when centered on the column in normal orientation. 900lbs full table articulation (when centered on the column in normal orientation), and 500lbs full table articulation including slide. Must have an intuitive hand control with easy to read LCD display and auto-collision safeguards in place. Must have dedicated buttons for access to smooth sectional articulation, return-to-level, floor lock activation, and patient positioning. Must have colored buttons and backlit screen. Must have a dual articulating headrest (tilt and height capability. Must have featherweight leg sections up to 14 lbs.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/898044abd33c4e689cdc26a715ebaf2e/view)
- Record
- SN06069199-F 20210723/210721230131 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |