SOLICITATION NOTICE
65 -- Phoenix ScriptPro Pkg 2
- Notice Date
- 8/2/2021 1:55:03 PM
- Notice Type
- Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- PCAC ACTIVATIONS (36A776) INDEPENDENCE OH 44131 USA
- ZIP Code
- 44131
- Solicitation Number
- 36C77621Q0421
- Response Due
- 8/16/2021 12:00:00 PM
- Archive Date
- 11/07/2021
- Point of Contact
- Ronald W Shelko, Procurement Technician
- E-Mail Address
-
ronald.shelko@va.gov
(ronald.shelko@va.gov)
- Awardee
- null
- Description
- FY21Q4-02 l JSN: M7280,M7280A,M7280B,M7280B1,M7280C,M7280D,M7265, l Dispensing System, Prescription, Robotic Statement of Work Page 1 of 8 Phoenix VA Health Care System Initial Outfitting, Transition & Activation Statement of Work Dispensing System, Prescription, Robotic (JSN: M7280, M7280A, M7280B, M7280B1, M7280C, M7280D, M7265 PKG # FY21Q4-002 Phoenix VA Health Care System 400 North 32nd St. Phoenix, AZ 85008 Phoenix VA Clinic - 32nd Street INTRODUCTION Veteran Affairs Phoenix Health Care System has a requirement to purchase Dispensing System, Prescription, Robotic (JSN: M7280, M7280A, M7280B, M7280B1, M7280C, M7280D, M7265 with an authorized vendor to supply and deliver the item(s) identified in Table 1 below. See salient characteristics below. This is a Brand Name Requirement. This requirement is in support of the activation of the Phoenix VA Clinic 32nd Street Project. The new Outpatient Clinic has the need for a Dispensing System, Prescription, Robotic for the pharmacy department. ScriptPro is the basis for design. Table 1 Package Items Summary Item # JSN Item Description Part # (basis of design) Quantity 1 M7280 Robotic Prescription Dispensing System with 6 slot Collating Control Center SP 200/CCC (6 slot 2 2 M7280 Full Disk Encryption (per covered Server computer) 2 3 M7280A SP Central Expanded Platform (includes 1 SP Central Expanded Server, 1 SP Datapoint) 1 4 M7280A ScriptPro Inventory Management Module 1 5 M7280A Virus Protection (Platform System) (Remote) 1 6 M7280B Pharmacy Printer 8 7 M7280B Terminal Emulation/Service/KVM Setup (initial device) 1 8 M7280B Terminal KVM Device Add-On (per device) 10 9 M7280B1 Electronic Signature Device 3 10 M7280B1 Electronic Signature Device, Locking Stand 3 11 M7280C Rx Paperwork Printer 3 12 M7280C Rx Paperwork Printer Barcode Card 3 13 M7280D Prescription Notification Board XL -Prescriptions Ready 1 14 M7265 Eyecon Model 9420 2 15 M7265 Standard Interface -Pharmacy Management System Interface, Eyecon Interface and Rx Paperwork Interface 3 16 M7265 Eyecon Interface Controller 1 17 M7280/ M7280A/ M7280B/M720B1 Smart Card Scanner 14 18 M7280B/M7280B1 Pharmacy Data Terminal 10 19 M7280/ M7280A/ M7280B/M720B1/ M7280C/M7280D/ M7265 Annual Subscription & Support 1 Additional Item Requirements The vendor will provide service manuals that includes theory of operation, maintenance requirements, repair information, schematics, part lists and troubleshooting information in electronic format for use by the VA IT Operations Department. Date of manufacture must not be greater than 2 years before the purchase order date. The equipment must not be used or refurbished and must have the latest manufacturer s software/hardware updates installed. Any batteries provided with the unit will not be manufactured more than 12 months before the purchase order issue date. GENERAL CONDITIONS Site Address The address of the Phoenix VA Health Care System Outpatient Clinic is provided below. 400 North 32nd St. Phoenix, AZ 85008 Delivery Schedule Items shall be delivered no earlier than the estimated delivery start date and no later than the delivery end date listed in Table 2 below. Table 2 Anticipated Building Outfitting Schedule Building Name Building # & Letter Acronym Est. Delivery Start Date Est. Delivery End Date Phoenix VA Clinic 32nd Street 400 7 DEC 2021 7 JAN 2022 Schedule and Order Management 2.3.1 The above delivery schedule is based upon the current construction schedule Due to the nature of activation efforts and construction timelines and dates may vary and shift. Delivery dates need to be flexible. The delivery of items for installation are dependent upon the completion of applicable areas within the building. If there is a delay, the Contractor may be required to adjust the delivery date at no cost to the Government. The Contractor will coordinate with the on-site POC s before delivery. 2.3.2 The awardees actual delivery dates will be confirmed by VA upon award. 2.3.3 Post-award, the vendor will coordinate delivery identified in this document with the VA prior to beginning any work (See Section 2.4). Once the dates have been confirmed, modifications to the schedule are subject to written approval by the CO, COR and the vendor. Delivery and Receiving Delivery and receipt of the proposed items is anticipated to be directed to the location identified below. Confirmation of delivery location will be provided post-award. To coordinate delivery, contact Government POC Jerrell (Jeff) Cockrell at (636) 395-9761, Jerrell.cockrell@sme-solutions.co, and Robert Stonerook at (706) 304-7194, Robert.stonerook@sme-solutions.co. Phoenix VA Clinic 32nd Steet (Direct Delivery to address detailed in paragraph 2.1) The vendor is required to define the need for a staging area to accommodate item delivery, if needed. Post-award, this information will be confirmed with the vendor. The delivery of items identified in this document shall take place during normal loading dock business hours which are defined as: 8:15 AM to 3:00 PM Arizona (local) Time, Monday through Friday, and excluding Federal Holidays. Delivery trucks will not be permitted to remain at the loading dock. Trucks shall be unloaded, moved from the dock, and then brought back to the dock if required to haul out any waste, tools, or excess materials. Labeling of delivered items shall include the VA facilities contract number and VA purchase order number for identification and reference upon receipt of product. NOTE: Due to the COVID19 situation, masks are required to be worn by all individuals when in common areas on VA property. Any individuals who need to enter the building for installation &/or training will be required to be screened by the site staff prior to entry. Please allow time for this in your schedule. Clean Up and Disposal There are no dumpsters available for vendor use. The removal of waste and/or excess material shall be conducted through the loading dock area. Assembly, Installation, and Calibration Required (Yes No ) The vendor is required to manage and coordinate installation at the Phoenix VA Clinic 32nd Street with the COR or his representative IOT&A POC. On-site assembly and installation of items, and performance of services identified in this document shall take place during normal business hours which are defined as: 8:00 AM to 4:30 PM Arizona Time, Monday through Friday, and excluding Federal Holidays. Proposed installation date will occur after delivery of equipment. Current timeframe of delivery is December 7, 2021 January 7, 2022. The vendor is required to define the need for a staging area to accommodate item assembly and installation, if needed. Post-award, this information will be confirmed with the vendor. The vendor is required to provide tools, labor and materials to complete assembly and installation of the items detailed in this document. The vendor shall protect all finished spaces and surfaces as required from delivery and installation damage. The vendor shall use covering and protection to the extent necessary to prevent damage to finished spaces. Any damage occurred during delivery and installation is the responsibility of the vendor. The vendor will be responsible for paying for and repairing any damage or noted deficiencies to finished spaces and surfaces that occur because of the vendor s (or associated sub-contractors) installation. During the entire duration of assembly and installation, the vendor will have a competent representative on-site as the vendor s contact, and to serve as the interface between the vendor and the Phoenix VA Clinic 32nd Street. On-site representative can be the installer. All instructions provided from COR to the representative will be binding as if given to the vendor s main contact. The COR may provide specific instructions, however, only the Contracting Officer may change the terms or conditions of the contract. Training Required (Yes No ) The vendor is required to provide live clinical training on set up, operation, shut down, and troubleshooting procedures to nursing staff. The vendor shall coordinate training dates with the on-site Project Manager. Post-award, these dates will be confirmed with the vendor to meet the clinical schedule. Proposed training date will occur after installation of equipment. Current timeframe of training is January 2022. The vendor shall provide documentation and/or certification to each staff member that has successfully completed the training. Confidentiality and Non-Disclosure This equipment does connect to a VA network. Therefore, in accordance with Appendix A, Handbook 6500.6 Checklist, block 6, the C&A requirements do apply to this requirement, and a Security Accreditation Package is required. This equipment does hold or store patient information. Therefore, in accordance with Appendix A, Handbook 6500.6 Checklist block 7, Appendix B and C provisions apply. Appendix B: The contractor, their personnel, and their subcontractors shall be subject to the Federal laws, regulations, standards, and VA Directives and Handbooks regarding information and information system security as delineated in this contract. Appendix C: VA will own this equipment. If vendor needs access during delivery, assembly, install or repair, the contractor shall be escorted by a VA employee to ensure there is no exposure to VA sensitive information. If the contractor is required to be on site for more than two consecutive days, VHA Privacy Training, TMS Course VA10203, is required and available at https://www.tms.va.gov/SecureAuth35/. The contractor will provide all consumable supplies necessary for training and competency assessment of hospital staff. Proof of training will be provided to the COR upon request. SALIENT CHARACTERISTICS Dispensing System, Prescription, Robotic (JSN: M7280) Total Quantity: 2 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center , MFG P/N SP 200/CCC 6 slot CLINs: 1 and 2 Brand Name Salient Characteristics: Must fill, label, and collate up to at least 150 vials per hour Each slot must display the patient name for easy vial retrieval Must hold up to 200 dispensing cells that are easily calibrated on-site by pharmacy staff Must have a count accuracy of at least 99.5% Must support tablets & capsules of all shapes& sizes Must operate with gravity-based dispensing creating no pill dust and no cross-contamination Must have electronic displays on both sides of the control center which show the contents of the slot Scalable control center options: 12-slot CCC, 6-slot CCC, and Open Control Center Must include a 17"" touchscreen Monitor with articulating arm Must have no more than a 22sq. ft. footprint The system must print and apply the prescription and auxiliary labels and collate the uncapped vials into slots for final inspection using on-screen drug image verification SP Central Expanded Platform with ScriptPro Inventory Management Module (JSN: M7280A) Total Quantity: 1 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 3, 4, 5, 17, 19 Brand Name Salient Characteristics: Must provide centralized system management and data processing Must be configurable and scalable to meet pharmacy-specific needs Must offer robust reporting and digital data storage functionality SP Central Workflow System must support both desktop and rackmount servers SP Central must provide barcode safety and controls to promote increased dispensing accuracy HIPAA compliance forms must be provided as system reports and electronic signatures must be available for form acknowledgement Pharmacy Printer and Terminal Emulation/Service/KVM (JSN: M7280B) Total Quantity: 8 (printer) / 10 (KVM) Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 6, 7, 8, 17, 18, and 19 Brand Name Salient Characteristics: Must be a compact and interactive countertop unit Must provide seamless workflow control and dispensing accuracy Must have an adjustable height touchscreen monitor CCD Barcode Scanner supports scanning linear and 2D barcodes Must have counter and wall/floor mount options available SP Datapoint must work in conjunction with ScriptPro s SP Central Pharmacy Management, Workflow, and Telepharmacy Systems to process prescriptions from point of entry to point of sale Must display on-screen prescription status lists, automate the collation of patient prescriptions, and provide paperless prescription tracking and batching for each patient Must not weigh more than 45 lbs Monitor must be at least 17"" touchscreen and adjustable height and tilt Electronic Signature Device with Locking Stand (JSN: M7280B1) Total Quantity: 10 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 9, 10, 17, 18, and 19 Brand Name Salient Characteristics: Must be a compact and interactive countertop unit Must provide seamless workflow control and dispensing accuracy Must have an adjustable height touchscreen monitor CCD Barcode Scanner supports scanning linear and 2D barcodes Must have counter and wall/floor mount options available SP Datapoint must work in conjunction with ScriptPro s SP Central Pharmacy Management, Workflow, and Telepharmacy Systems to process prescriptions from point of entry to point of sale Must display on-screen prescription status lists, automate the collation of patient prescriptions, and provide paperless prescription tracking and batching for each patient Must not weigh more than 45 lbs Monitor must be at least 17"" touchscreen and adjustable height and tilt Rx Paperwork Printer (JSN: M7280C) Total Quantity: 3 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 11, 12, and 19 Brand Name Salient Characteristics: Must print up to 50,000 pages per month Must have a maximum input capacity of up to 4,400 sheets and a high yield toner cartridge Must be able to print up to 55 pages per minute Can t be more than 53lbs Prescription Notification Board XL (JSN: M7280D) Total Quantity: 1 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 13 and 19 Brand Name Salient Characteristics: Must offers efficient, easy-to-see in-store prescription notifications Must minimize wait times and improves customer service Must be configurable to protect PII, configurable to show full or protected patient name Must also supports pharmacy-specific messaging Cant weigh more than 40lbs Must have a 40 screen size with 1920 x 1080 resolution and a 16:9 aspect ratio Counter, Pill/Tablet, Automated, Counter Mounted (JSN: M7265) Total Quantity: 2 Network Required if Checked Manufacturer Certified Installation Required if Checked BMET Training Required if Checked End User Training Required if Checked Basis of Design is Script Pro Robotic Prescription Dispensing System with 6 slot Collating Control Center, MFG P/N SP 200/CCC 6 slot CLINs: 14, 15, and 19 Brand Name Salient Characteristics: Must count poured pills in 200ms Must have an onscreen count that is updated five times per second Must support accurate manual fills, double counts, stock bottle back counts, and physical inventory counts Validation mode ensures patient safety with proper dispensing Must separate sulfa and penicillin platters to prevent cross contamination Must recognize and identify foreign matter and tablet fragments of dissimilar size and shape The open design allows quick and easy inspection of the medication being dispensed Must count all sizes and shapes of capsules and tablets. Can also be used for validation and inventory of ointments, creams, solutions, and pre-packs Must produce an annotated pill tray photograph with individually numbered pills is saved for every Rx transaction Must be able to view various transaction reports on the screen and exported when needed. The pill tray photos associated with any selected transaction can be viewed on the screen or any network computer Must be able to connect the pill counter to the pharmacy management software (PMS)
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/a0662a7c38da4fddbd5c789ba8f96426/view)
- Record
- SN06081789-F 20210804/210802230122 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |