SOURCES SOUGHT
65 -- Interacoustics Titan (Brand Name) This is not a request for quote.
- Notice Date
- 8/2/2021 3:59:17 PM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24421Q1053
- Response Due
- 8/6/2021 12:00:00 PM
- Archive Date
- 11/04/2021
- Point of Contact
- Allan Tabliago, Contract Specialist, Phone: 215-823-5800x203443
- E-Mail Address
-
allan.tabliago@va.gov
(allan.tabliago@va.gov)
- Awardee
- null
- Description
- Page 5 of 5 THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. See Instructions on page 7. Interacoustics Titan (Brand Name) INTRODUCTION/BACKGROUND: The Interacoustics Titan is a portable, lightweight, and compact tympanometer that performs standard tympanometry, acoustic reflex, and reflex decay and latency tests. The additional DPOAE module offers otoacoustic emissions testing as well for a comprehensive audiologic evaluation. OBJECTIVE: Audiology Department, Wilmington VA Medical Center, (460) Wilmington, Delaware, hereby referred to as the Wilmington VAMC (460), is seeking the acquisition of one (1) Interacoustics Titan: Line No. Part No. Description Qty Unit 0001 8016195 Interacoustics Titan Ver.4 Clinical w/multiple Probe Tones 1 EA 0002 8121646 Titan DPOAE Module 1 EA 0003 8070 Installation 1 EA 0004 8074 Equipment Setup and User Training 1 EA 0005 Touch Screen Monitor, extended HDMI, extended USB A to B cable. extended USB A to mini. Articulating Mounting Arm. 1 EA MAJOR REQUIREMENTS: The Contractor/ Vendor must complete the following tasks to meet the needs of this acquisition: Capabilities: Screening highlights DPOAE440 DP range 0.5-6kHz TE range 1-4.5kHz (60-84 dB SPL) Customizable PASS/REFER criteria Advanced AGC Bayesian weighted averaging Noah & Hitrack compatibility 226Hz tympanometry Online quick guides for fast learning Pressurized OAE (optional) Operate from Titan or PC (optional) Clinical highlights DPOAE440 DP range 500Hz-10kHz TE range 500Hz-5.5kHz (30-90 dB SPL) Fully customizable protocols Basic & Advanced view Manually controlled test time Unlimited test points Advanced AGC Bayesian weighted averaging Noah & Hitrack compatibility DP Input/Output test 226Hz tympanometry Operate from Titan or PC Pressurized OAE Hardware: General PC control USB: Titan can be fully operated from a PC via a USB connection. Data can be stored on the device in handheld mode and transferred and saved on the PC in a database (OtoAccess® Database or Noah) via USB. Wireless: Titan can be fully operated from a PC via a wireless connection. Data can be stored on the device in handheld mode and transferred wirelessly and saved on the PC in a database (OtoAccess® Database or Noah). Memory The Titan includes a built-in 8 GB memory card. PC storage capacity is limited to the size of the database (OtoAccess ® Database or Noah). It is recommended to store a maximum of 250 clients on the device. Thermal printer (Optional) Type: Thermal printer with recording paper in rolls. Print on command through wireless communication printer. Paper width: 57.5 ± 0.5 mm on thermal printer Printing time: Printing time depends on the size of the used protocol. For 2 tympanograms and 8 reflexes the thermal printer uses approximately 6s. User interface Screen type: TFT with LED backlight Display size: 3.4 x 4.5 cm / 1.3 x 1.7 inches Dimensions 6 x 6 x 28 cm / 2.4 x 2.4 x 11 inches Titan Weight 360 g / 0.8 lbs Preamplifier weight 120 g / 0.26 lbs Preamplifier dimensions 10.2 x 6.8 x 2.6 cm / 4 x 2.7 x 1 inches Preamplifier cable length Short extension cable length 40 cm / 15.7 inches Long extension cable shoulder box weight 66 g / 0.14lbs Long extension cable shoulder box dimensions 9.5 x 4.5 x 2.2 cm / 3.7 x 1.8 x 0.8 inches Long extension cable length 234 cm / 92 inches Impedance measuring system Probe tone Frequency: Classic tympanometry: 226 Hz, 678 Hz, 800 Hz, 1000 Hz; pure tones; AGC controlled to protect for loud probe tone stimuli in small ear canals. WBT: 226 Hz 8000 Hz broadband stimulus, 21.5/sec. Level: 226 Hz: 85 dB SPL ( 69 dB HL) WBT: 96 dB peSPL (infant) / 100 dB peSPL (adult). (100 dB peSPL 65 dB nHL) Air pressure Control: Automatic. Indicator: Measured value is displayed on the graphical display. Range: -600 to +300 daPa. Pressure limitation: -750 daPa and +550 daPa. Pressure change rate: Minimum, medium, maximum or automatic with minimum speed at compliance peak. Selectable in the setup. Compliance Range: 0.1 to 8.0 ml at 226 Hz probe tone (Ear volume: 0.1 to 8.0 ml) and 0.1 to 15 mmho at 678, 800 and 1000 Hz probe tone. Test types Tympanometry Automatic, where the start and stop pressure can be userprogrammed in the setup function. Manual control of all functions. Eustachian tube function 1 Non perforated eardrum Williams test Eustachian tube function 2 Perforated eardrum Toynbee test Eustachian tube function 3 Patulous Eustachian tube Continuous sensitive impedance measurement for 30 up to 150 s. Indicators Graphical display Compliance is indicated as ml and pressure as daPa. In PC controlled mode admittance, susceptance and conductance can be printed. Stimulus level is indicated as dB Hearing Level. Memory Tympanometry: 1 curve per ear per tympanometry test. 3 curves per ear per Eustachian tube function test. And theoretically an infinite number of tests per protocol. There is no deviation between static and dynamic mode. DPOAE Stimulus Frequency range: 500 to 10000 Hz Nominal frequency: f2 Frequency step: 1 Hz Level: 30 to 80 dB SPL (75 dB SPL for 6kHz and 65 dB SPL for 8kHz to 10kHz) Level Step: 1 dB Transducer: Recording Analysis time: 1 second to unlimited time A/D Resolution: 24-bit, 5.38 Hz resolution Artifact rejection system: -30 to +30 dB SPL or off Stimulus tolerance: Adjustable between 1 and 10 dB SNR criteria: Adjustable between 3 and 25 dB DP criteria: SNR, Min DP level, DP tolerance, Residual noise, mandatory points, DP reliability Probe check window: 256 points frequency response of the ear canal due to a click stimulus. DP-response window: 4096 points frequency response Averaging method: Bayesian weighted averaging Residual noise: A RMS average measurement in the DP-bin frequency area (26 bins at frequencies < 2500 Hz & 60 bins 2500 Hz). Display Other information: In ear status (before/after test), noise rejection level, tympanic peak pressure Basic or advanced view of the DP-Gram, test summary table, point summary table Probe specifications Titan IOWA probe: Clinical extension cable with fixed IOWA probe. Auto detection and auto calibrated. IMP, DPOAE and TEOAE capable Replaceable probe tip Test Pressure Ambient pressure Tympanic peak pressure (from IMP module) The Government and the Contractor understand and agree that the services to be delivered under this contract by the Contractor to the Government are non-personal services and the parties recognize and agree that no employer-employee or master-servant relationships exist or will exist under the contract between the Government and the Contractor s employees. POINT OF CONTACT (POC): The identified POC and technical representative for this acquisition is: Name: Joseph Chiarello Phone Number: 302-994-2511 x4710 Email: joseph.chiarello@va.gov ""No Government personnel, other than the Contracting Officer, have the authority to change or alter these requirements. The COR shall clarify technical points or supply relevant technical information, but no requirements in this scope of work may be altered as a sole result of such verbal clarification."" REPORTS/DELIVERABLES: Delivery confirmation of equipment and commodities will be made through the Logistics Department of the VAMC Wilmington (460). This will include documentation of receipt and assignment of a facility based EE number for identification and tracking purposes. Delivery confirmation of non-equipment/ commodities acquisitions is the responsibility of the receiving Facility and/ or Service. Request for Information Instructions The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 334516 (size standard of 1000 employees). Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. Does your company exceed 500 employees; Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; Obtained an individual or class waiver? If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. Please submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes? Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (12) Please provide your DUNS number. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to allan.tabliago@va.gov no later than, 3:00 PM Eastern Standard Time (ET) on August 5, 2021. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, Allan Tabliago. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at allan.tabliago@va.gov. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/dd2de161fcb84f80a8d6ba227432d1a5/view)
- Place of Performance
- Address: Cumberland County Community Clinic Vineland CBOC 79 W. Landis Ave., Vineland, NJ 08360, USA
- Zip Code: 08360
- Country: USA
- Zip Code: 08360
- Record
- SN06082070-F 20210804/210802230124 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |