SOLICITATION NOTICE
65 -- Clinical Training Software
- Notice Date
- 8/4/2021 1:37:00 PM
- Notice Type
- Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 252-NETWORK CONTRACT OFFICE 12 (36C252) MILWAUKEE WI 53214 USA
- ZIP Code
- 53214
- Solicitation Number
- 36C25221Q1024
- Response Due
- 8/11/2021 4:00:00 AM
- Archive Date
- 08/26/2021
- Point of Contact
- Vernise L Newton, Phone: 4148444800
- E-Mail Address
-
vernise.newton@va.gov
(vernise.newton@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Description
- 36C25221Q1024 for Clinical Training Software as a Brand Name or Equal requirement, Ventilation Mode Requirements: Must be capable of the following ventilator modes: �Volume-controlled Ventilation (VCV) �SIMV-VC �Pressure-Controlled Ventilation (PCV) �Pressure Controlled, Volume Guaranteed (PCV-VG) �SIMV-PC �SIMV-PCVG �Bi level Airway Pressure Ventilation (APVR capable) �PSV-VG �Non-Invasive Ventilation (NIV) and NIV-ST �CPAP/Spontaneous -Closed loop mode of ventilation to provide automated lung protective ventilation strategies to spontaneous and passive breathing patients. Patient Monitoring Alarms: � Patient Monitoring Alarms: � -Low/high minute volume� - Low/high pressure - Low/high tidal volume - Low/high respiratory rate Apnea time - Low/high PetCO2� - Low/high pulse - Low/high SpO2� - Low/high SpMet - Low/high SpOC - Percent leak -PI (perfusion index) -Humidifier water level �-Humidifier temperature - Humidifier tilt� -Disconnection -Oxygen alarm limit exceeded� -Oxygen concentration �-Disconnection - Loss of PEEP Exhalation obstruction - HLI� -High PEEP alarm - Flow sensor alarms� -ASV/APV - CO2� -Power supply - Gas supplies� -Cuff leakage Ventilator Display Requirements: -Real-time visualization of the lungs with representations of tidal volume, lung compliance, resistance and patient activity, including hemodynamic status and cuff pressure� -Visual representation of ventilator dependency and weaning process, grouped into oxygenation, CO2 elimination, patient activity, PetCO2 , SpO2 , pulse, and heart lung index (HLI)� -Graphic display of target and actual parameters for tidal volume, frequency, pressure, patient activity and minute ventilation Display of more than 50 monitoring parameters� -Up to 8 waveforms at a glance based on: Paw, Pes, Paux, Volume, Flow, FetCO2 , PetCO2 , SpO2� -Up to 4 loops at a glance based on: Volume, Flow, Paw, Pes, Paux, Ptranspulm, SpO2 , CO2 , reference loops� -Simultaneous display of up to 17 parameter trends, selected from all monitoring parameters, for 1, 3, 12, 24, or 96 h� -Storage and display of up to 1,000 events with date and time stamp Graphic curve freeze and cursor function, inspiratory and expiratory hold; user configurable default graphics layout Ventilator Features/Procedure Requirements: -Suction Maneuver -Automatic patient detection -Screen snapshot - Spirometry - Integrated Medication nebulization including and ability to set phase cycle and duration of nebulization - Integrated Aerogen nebulizer -Automatic pulmonary mechanics measurements that include static compliance, inspiratory/expiratory resistance, auto PEEP and inspiratory/expiratory time constants -Integrated capnography with volumetric CO2 measurement -Integrated pulse oximetry -Automated ET and Trach tube cuff pressure maintenance and monitoring - Automatic maneuver for static compliance assessment and lung recruitment including transpulmonary pressure. - Esophageal pressure monitoring and automated calculation of end inspiratory transpulmonary pressure/ end expiratory transpulmonary pressure -Uses a proximal flow sensor to precisely measure the pressure, volume and flow directly at the patient�s airway opening. -High flow oxygen therapy -Heliox therapy Ventilator Communication Requirements: -USB and Compact Flash for screenshots Updates and log data - DVI with VGA output -2 serial RS-232 ports (data monitoring / humidifier control) - Special data interface for nurse call and alarm output: SpO2 & CO2 sensor, Aerogen and Cuff interface Patient Types requirement: -Adult -Pediatric -Neonatal
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/1408f99d514243e5896f84f51844c6a7/view)
- Place of Performance
- Address: IL 60141, USA
- Zip Code: 60141
- Country: USA
- Zip Code: 60141
- Record
- SN06085296-F 20210806/210804230130 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |