Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 07, 2021 SAM #7189
SOLICITATION NOTICE

41 -- Cooling Circulation Pumps and Installation

Notice Date
8/5/2021 3:24:15 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
W2R2 COLD RGNS RSCH ENG LAB HANOVER NH 03755-1290 USA
 
ZIP Code
03755-1290
 
Solicitation Number
W913E521Q0027
 
Response Due
8/23/2021 10:00:00 AM
 
Archive Date
09/07/2021
 
Point of Contact
Kim D Roberson, Phone: 2173733478, ERDC-CRREL
 
E-Mail Address
kim.d.roberson@usace.army.mil, ERDC-CRREL-QUOTES@usace.army.mil
(kim.d.roberson@usace.army.mil, ERDC-CRREL-QUOTES@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. �This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.� The solicitation number W913E521Q0027 is being issued as a request for quotation (RFQ). This requirement is a total set-aside for small business concerns in accordance with FAR 19.502-2. The associated North American Industry Classification System (NAICS) code is 333415 � Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing was identified as the most representative NAICS code for this requirement. �Small business size standard is 1,250 employees. The United States Army Corps of Engineers (USACE), Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL) has a requirement for procurement of seven (7) extreme low temperature process glycol pumps; the installation of two (2) of the new pumps with the option of installing an addition four (4); and ancillary installation supplies for distributing process glycol to research applications at the CRREL�s Frost Effects Research Facility (FERF) and Material Evaluation Facility (MEF). Specifications: New pumps are necessary for the Industrial Process Cooling circulation loops which draw glycol from the FERF main glycol buffer tanks and distribute them to downstream RDT&E applications. The new pumps shall be supplied with sheet metal protective covers against rain, debris and snow, which are painted white to avoid excessive heating. The Vendor shall provide equipment and services to meet the following specifications:� A.�� �Low Temperature Pumps Vendor is to quote supply of three (3) low temperature pumps. Vendor will install two on the low temperature glycol loop at the FERF and supply one to CRREL as a SPARE. The Low Temperature Pumps shall meet the following specifications:� Rated to operate with a glycol/water mixture of at least 60% Dow Norkool SLH and 40% water. All seals, fittings, components and specifications must be based on 60/40 Dow Norkool SLH / water.� Size: 2.5x3-10. This is a requirement for a 2.5-inch discharge, 3-inch suction, and CP size of 36.� Must be for use with ANSI class 150 mating flanges. Flanges must be supplied by vendor.� GPM rating: 282 GPM rating or better. Head rating: 69-FT TDH @ 282 GPM with 60/40 Dow Norkool SLH. Motor rating: 7.5 horsepower, 3/60/208-230/460 VOLT, 1750 RPM.� Pump material: 316L stainless steel throughout. Seals: 10K126 SIL-Carbide EPR throughout.� Frame: Stainless steel support frame.� Temperature rating: -45F minimum to 120F maximum.� B.�� �Medium Temperature Pumps (Option).� Vendor shall quote supply of four (4) medium temperature pumps. The vendor shall install all four (4) pumps, with two (2) each on the hot temperature glycol and medium temperature glycol loops respectively. The medium temperature pumps must meet the following specifications: Rated to operate with a glycol/water mixture of at least 60% Dow Norkool SLH and 40% water. All seals, fittings, components and specifications must be based on 60/40 Dow Norkool SLH / water.� Size: 2.5x3-10. This is a requirement for a 2.5-inch discharge, 3-inch suction, and CP size of 36.� Must be for use with ANSI class 150 mating flanges. Flanges must be supplied by vendor.� GPM rating: 282 GPM rating or better. Head rating: 69-FT TDH @ 282 GPM with 60/40 Dow Norkool SLH. Motor rating: 7.5 horsepower, 3/60/208-230/460 VOLT, 1750 RPM.� Pump material: 316L stainless steel throughout. Seals: 10K126 SIL-Carbide EPR throughout.� Frame: Stainless steel support frame.� Temperature rating: -15F minimum to 120F maximum.� C.� Ancillary Equipment Supply Electrical Supply: Vendor is to supply two (2) electrical disconnects with an option for an additional four (4) electrical disconnects, one for each unit to be installed. Each electrical disconnect will re-use the existing feeder cables.� D.�� �Cover Supply: Vendor is to supply two (2) framed steel boxes, with an option for four (4) framed steel boxes for protecting the pumps from the elements. These boxes will mount to the concrete pad or to the frame. They will provide at least one foot of standoff from all components of the pump. They will have holes, sealed at install, for the inlet and outlet pipes and the electrical supply. They will have at least three removable sides (top and two other sides, depending on configuration) which are connected with at least four (4) quick release latches each. The framed steel boxes shall be painted highly reflective white in outdoor duty, rust-resistant metal paint (two layers) with a primer layer below.� E.�� �Suction and Discharge Fittings: Vendor will supply new suction and discharge fittings, up to two feet in length each (flexible, metal woven jacket) to connect to existing piping. These will match ANSI 150 rated piping and be rated down to -45F. Vendor will supply three (3) with an option for an additional four (4), up to a total of seven (7); fittings may be multi-part depending on manufacturer but should be supplied one each complete with all parts necessary to work in this application and specified length.� F.�� �Installation. Vendor shall install six (6) pumps, two (2) being low temperature pumps and optionally, an additional four (4) medium temperature pumps. These pumps are installed in parallel in three (3) loops, the high temperature, medium temperature, and low temperature loops. The medium and high temperature loops are the process glycol loops for the optional CLIN. The medium temperature pumps will be used in the HT and MT loops and the low temperature pumps in the LT loop. Vendor will conduct a site survey before ordering fittings and will fabricate supports and framed steel boxes according to site conditions for successful installation of the pumps.� Please reference the attached RFQ for the Purchase Description (PD), as well as all applicable provisions and clauses. �The following factors shall be used to evaluate offers: ability to meet the required technical specifications, delivery schedule, past performance, and price. �Award will be made to the responsible offeror whose offer represents the best value to the Government, in consideration of all factors. �The basis for award will be an acceptable proposal, the price of which may not be the lowest. Delivery shall be FOB Destination to ERDC-CRREL, 72 Lyme Road, Hanover, NH 03755. All installation services shall be performed at the ERDC-CRREL facilities. Payment Terms: Net 30 Please provide responses to this notice, no later than 12:00PM (CDT), Monday, 23 August 2021 to: Kim.D.Roberson@usace.army.mil Telephone responses will not be accepted. *Note: In order to be eligible for award of a Government contract, vendors must be actively registered in the System for Award Management (SAM), have no active exclusions, and complete representations and certifications. For more information, review the SAM website at https://www.beta.sam.gov.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/d1a40a88236142c087686021afbeaca8/view)
 
Place of Performance
Address: Hanover, NH 03755, USA
Zip Code: 03755
Country: USA
 
Record
SN06086849-F 20210807/210805230127 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.