SOLICITATION NOTICE
S -- 21 Drum HAZMAT Storage
- Notice Date
- 8/12/2021 4:20:49 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 493190
— Other Warehousing and Storage
- Contracting Office
- W7NR USPFO ACTIVITY NYANG 106 WESTHAMPTON BEACH NY 11978-1201 USA
- ZIP Code
- 11978-1201
- Solicitation Number
- F9E1PJ1139AW01
- Response Due
- 8/19/2021 7:00:00 AM
- Archive Date
- 09/03/2021
- Point of Contact
- Anthony Kirincic, Phone: 6317237562, Sara Margaret E Luna, Phone: 6317237569
- E-Mail Address
-
anthony.kirincic@us.af.mil, sara_margaret.luna.1@us.af.mil
(anthony.kirincic@us.af.mil, sara_margaret.luna.1@us.af.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This acquisition is for a hazmat storage building/container�for the 106th Rescue Wing of the New York Air National Guard, F.S. Gabreski ANG, Westhampton Beach, NY 11978. This is a 100% Small Business set-aside. The applicable NAICS code for this acquisition is 493190�and the size standard is 30 million dollars. Solicitation number F9E1PJ1139AW01� �is being issued as a request for quote and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-05 Effective March 10, 2021. Firms must be registered in the System for Award Management (SAM) before an award can be made. To register with SAM, log on to https://www.sam.gov. This Request for Quote will result in a firm fixed price contract. This announcement is the solicitation which will result in a firm fixed-price contract. Contract will be awarded to the contractor whom provides a quote that conforms to the terms and conditions of this combined synopsis / solicitation and meets all the requirements that is outlined and is determined responsible IAW FAR Subpart 9.104-1. � FOB: Destination Include the following information on your quote: cage code, tax id number, company name, phone number, POC, signature of authorized representative and email. Offerors' quotes shall be valid for a minimum of 30 days to be acknowledged in the offerors' quote. Offerors must have electronic funds transfer (EFT) capability. Contractors must be actively registered with iRAPT, formally the Wide Area Work Flow (WAWF) at http://wawf.eb.mil. 4HRBFR 15X7X9 21DRUM -S2 - 2 BAY STORAGE OR LIKE ITEM -1 EACH Wind Load: 120 MPH Exp. C Floor Load: 250 psf Snow Load: 40 psf Seismic: Category C Sump Capacity: 311 Gallons Drum Capacity: 21 -welding procedures are in accordance with the American Welding Society and meet standards set forth by the ASTM, and all welds are sufficient in size and shape to accommodate wall designs and loads. Four hour bi-directional fire rated, weatherproof construction that meets or exceeds UL 263 and ASTM E-119. Framework connected by welding. Construction consists of multiple layers of UL Listed gypsum wallboard encased between Galvanneal steel sheets on interior and exterior faces for maximum durability. Gypsum wall board layers are offset with overlapping joints. Mineral wool installed in the wall cavity with a R- 12 minimum rating. ROOF SYSTEM: One (1) hour Per IBC Section 722, fire rated Class A flame spread rating. Wind uplift exceeds UL I- 60 and is constructed of 1 hour fire rated, weatherproof construction. Exterior roof sheets are continuously welded to roof supports at each seam. HRS steel roof with multiple layers of UL Listed fire resistant gypsum wall board lined on the interior with galvanealed steel sheets on interior. Assembly meets or exceeds UL 263 and ASTM-E119. Roof is sloped to facilitate runoff and door(s) are equipped with rain shields on exterior. 7/ COLOR,STD,BLEACHED BONE 1 COLOR - BLEACHED BONE DOOR 36 X 80 3HR RIGHT STD 2 SINGLE DOOR, 36"" WIDE X 80"" TALL, 3 HOUR FIRE RATED UL CLASSIFIED & LABELED, 3 HOUR FIRE-RATED 36""W X 80""H SINGLE DOOR. EQUIPPED WITH A UL LISTED DOOR CLOSER AND A UL LISTED EXTERIOR KEYED LOCK. DOOR SERVES AS A ENTRANCE AND EXIT DOOR. SL2 PART WALL 5-7 4HR STD 1 INTERIOR SEPERATION WALL FOR SL2 MODELS (5' - 7' NOMINAL WIDTH). 4HR-FIRERATED WALL CONSTRUCTION, SEPERATION WALL EXTENDS FROM SUMP BASE TO CEILING. � LC 240V-1P 8 SPACE 100A 3R UL LISTED, SINGLE PHASE, 3 WIRE, 120/240V 100 AMP 8 SPACE LOAD CENTER (NEMA 3R). RAINPROOF AND SLEET- (ICE) RESISTANT- OUTDOOR ENCLOSURES ARE INTENDED FOR USE OUTDOORS TO PROTECT THE ENCLOSED EQUIPMENT AGAINST RAIN AND MEET THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES, INC., PUBLICATION NO. UL 508, APPLYING TO ""RAINPROOF ENCLOSURES."" OTHER ELECTRICAL CONFIGURATIONS AVAILABLE, ADDITIONAL COSTS MAY APPLY. LIGHT C1D2 LED 2FT LED LOW PROFILE, CEILING OR WALL MOUNT, 2FT NOMINAL LENGTH STRIP LIGHT. UL 1598A, 844, 1598, & 8750; CUL LISTED. CLASS 1, DIV 2, GROUPS A, B, C, & D. CLASS 2, DIV 2, GROUPS F & G. NEMA 4X. DESIGNED FOR USE IN HAZARDOUS LOCATIONS AND WHERE MOISTURE, DIRT, DUST, CORROSION AND VIBRATION MAY BE PRESENT. ALUMINUM BODY W/ GRAY EPOXY FINISH; T-ONE PIECE, NEOPRENE GASKET AND DIFFUSED POLYCARBONATE LENS. 120-277/1, 50 OR 60HZ. 3620 LUMENS, 27 WATTS EXPLOSION PROOF EXHAUST FAN 2 EXPLOSION PROOF EXHAUST FAN CONSISTING OF ONE (1) UL LISTED, CLASS I, DIVISION 1, GROUP C AND D TOTALLY ENCLOSED EXPLOSION PROOF 1/4 HP 1800 RPM MOTOR (115VAC, 4.5A, 60HZ, 1-PHASE) WITH NONSTATIC TWELVE-INCH (12) DIAMETER CAST ALUMINUM FAN BLADE, 1,160 CFM @ 0.0"" SP. EXTERNAL HOUSING CONSTRUCTED OF 18 GA STEEL. EXHAUST INTAKE VENTS LOCATED WITHIN TWELVE INCHES (12) OF THE FLOOR. ACTIVATED BY AN EXTERIOR UL LISTED FAN SWITCH. EXTERIOR EXHAUST FAN PORT OPENING EQUIPPED WITH SHUTTER ASSEMBLY AND SCREEN. DRY CHEM 21LB 1 UL, ULC LISTED AND FM APPROVED PRE-ENGINEERED DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR CLASS A,B AND C FIRES. EQUIPPED WITH MEANS FOR REMOTE ANNUNCIATION. SYSTEM INCLUDES FUSIBLE LINK DETECTION FOR AUTOMATIC ACTUATION, MANUAL PULL STATION, AND NOZZLE(S) FOR TOTAL FLOODING APPLICATION. AGENT STORAGE LOCATED ON BUILDING EXTERIOR IN WEATHERPROOF ENCLOSURE. AUDIBLE ALARM INCLUDED WITH SYSTEM. DRY CHEMICAL SYSTEMS SHIP WITH A FULL TANK OF SUPPRESSANT, PRICE MUST INCLUDE ARMING�BY A LICENSED TECHNICIAN ONCE THE BUILDING IS ON SITE. IT IS THE RESPONSIBILITY OF THE CUSTOMER TO ARRANGE AND COORDINATE THIS ARMING AND ANY RESULTING TESTS OR OTHER MAINTENANCE. SOME OF THE ELECTRICAL COMPONENTS WILL NOT OPERATE UNTIL THIS ARMING PROCESS HAS BEEN COMPLETED. SHELVING 3 TIER SYSTEM 60 LINEAR FEET OF THREE TIERS OF SUMP SHELVING: ADJUSTABLE 16"" LEAKPROOF STEEL SHELVING FORMED AND WELDED FROM HEAVY GAUGE STEEL WITH A 2"" LIP AROUND THE ENTIRE SHELF. SHELVING LENGTHS ARE APPROXIMATE AND MAY VARY DUE TO SPACE LIMITATIONS. TOTAL PRICE IS CALCULATED FROM QUANTITY OF LINEAR FEET QUOTED. WEIGHT CAPACITY: 75 LBS. PER LINEAR FOOT. MUST INCLUDE FREIGHT.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/eb4ad0c1768c4280b0fdab47780d381e/view)
- Place of Performance
- Address: Westhampton Beach, NY 11978, USA
- Zip Code: 11978
- Country: USA
- Zip Code: 11978
- Record
- SN06095029-F 20210814/210812230128 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |