SOLICITATION NOTICE
65 -- Eye lanes
- Notice Date
- 8/18/2021 3:45:52 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339115
— Ophthalmic Goods Manufacturing
- Contracting Office
- 258-NETWORK CNTRCT OFF 22G (36C258) MESA AZ 85212 USA
- ZIP Code
- 85212
- Solicitation Number
- 36C25821Q0348
- Response Due
- 8/30/2021 5:30:00 PM
- Archive Date
- 09/29/2021
- Point of Contact
- Nick W Price, Contracting Specialist, Phone: 480-466-7921
- E-Mail Address
-
Nicholas.Price@va.gov
(Nicholas.Price@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- Combined Synopsis-Solicitation for Commercial Items VHAPM Part 813.106 SAP: Soliciting Competition & Evaluation of Quotations SOP Page 3 of 5 Original Date: 10/12/17 Revision 04 Date: 06/10/20 Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-06 This solicitation is set-aside for Small Businesses Please make sure that your business follows the instructions in attachment B vendor FMS paperwork to get your Business Registered with the Department of Veterans Affairs. Failure to do so could delay award as it is the end of year. The associated North American Industrial Classification System (NAICS) code for this procurement is 339115 Ophthalmic goods manufacturing, with a small business size standard of 1,000 employees The FSC/PSC is 6540 Ophthalmic Goods and Supplies The Phoenix VA Health Care System is seeking to purchase Eye lanes with related accessories All interested companies shall provide quotations for the following: Supplies/Services Line Item Description Quantity Unit of Measure 1 INSTRUMENT STAND 5 EA 2 EXAM CHAIR 5 EA 3 PHOROPTOR 5 EA 4 INSTRUMENT HANDLE 5 EA 5 TRANSILLUMENATR 5 EA 6 DIRECT OPHTHALMOSCOPE 5 EA 7 DIRECT OPHTHALMOSCOPE 5 EA 8 WALL MOUNTED DIGITAL ACUITY 5 EA 9 CHAIR GLUIDE SYSTEM 5 EA 10 APPLINATION TONOMETER 5 EA INSTRUMENT STAND 5qty Instrument charging console (IC), which includes chair controls and three wells for handheld instruments (Must be compatible w/ Welch-Allyn Rechargeable Handles & any HS/Reliance Power Exam Chair) Counterbalanced slit-lamp arm locks and allows adjustment with a single hand. 12 of vertical travel can be counterbalanced for instruments 12 to 60 lbs. A raise and lower switch on the slit lamp arm controls chair height adjustments (Compatible with any unit model slit lamp) Upper refractor arm offers 10 range of vertical movement; delivers instruments up to 20 lbs Backlit membrane switches last 10-times longer than mechanical switches and increase safety with lower voltages. They control the chart projector, overhead lamp and binding post for an indirect ophthalmoscope; raise and lower the exam chair Halogen lamp with long-lasting bulb provides bright, direct light for minor procedures Arm adjusts without tools. Low voltage for safety. Gives user maximum patient access Unique injection molding process using a polycarbonate found on supersonic aircraft to resist scrapes, scratches, and scuffs Certified to comply with international quality and safety standards Wheelchair Access Deliver care to wheelchair bound patients with an optional lower slit lamp arm. Cost applies to Americans With Disability Act s Tax Credit Height to console: 36 Height to pole top: 71 Base: 21x 21 Electrical (Standard UL Listed), 115 volts, 60 Hz, 3 amperes EXAM CHAIR 5 qty Memory Positioning Switch enables you to pre-select the chair's most used position Power base and top Use finger switches or corded foot switch to raise, lower, or recline the chair. Square base Dual controls for base and top functions Use finger switches or corded foot switch to raise, lower, or recline the chair Membrane switches and rotation locks control all operations of the chair from a sitting or standing position Single lock adjustable concave headrest standard Safety Switch prevents small children from operating the chair by disabling side and footswitches Armrests lock in place Release mechanism allows patients to sit or leave from either side of the chair Padded underneath for comfort Hydraulic base tested to 600 pounds Base: 225/16 x 24½ Overall width: 24½ Overall depth (excluding headrest): 36 . Table position: 60 . Seat: 19 wide by 18½ deep Armrest distance: 19 Base heights: 20¼ lowered, 28¾ raised Standard electrical: 115 volts, 60/50 Hz, 6.3 amperes total. Optional: 230 volts, 50 Hz, 4.0 amperes PHOROPTOR 5qty (Compatible w/ALL Instrument Stands) carry a limited lifetime warranty Legendary feel and world-renowned mechanical quality Designed and assembled in the USA Precision geared rotary prism for more precise interpolation of small prism diopters Corrosion-resistant materials Accessories ± .25 Flip cross cylinder + 1.50 Retinoscopic Lenses Accessory Case 3 pair nylon face shields Rotochart Reading rod with card holder Sphere: -19.00D to +16.75D 0.25D Steps +0.12D Sphere in auxiliary dial included Cylinder Power: 0.00D to 6.00D 0.25D Steps Plus or minus lens system optional 0.12D and 2.00D accessory cells included Cylinder Axis 360 degrees (Double 0 to 180 degrees scale) 5 degrees graduations Cross Cylinder: ± 0.25 ± 0.37 or ± 0.05 Optional Prism: 0 to 20 Prism Diopter, 1 Prism Diopter graduations P.D.: 48 mm to 75 mm, 1 mm graduations Vertex Distance: 13.75 mm (normal) Graduations extend range by 6 mm Reading Distance: 5 to 28 inches Centimeter and diopter scales included Auxiliary Dial: 10 lenses plus 2 open apertures INSTRUMENT HANDLE - RECHARGEBLE 15qty (Compatible w/ALL Welch Allyn 3.5V instrument heads) Rechargeable Adjustable rheostat control Free-floating reserve for optimal intensity and battery life Rechargeable nickel-cadmium battery is included Safety switch prevents accidental draining of battery Smooth, non-abrasive knurled finish for no-slip grip Metal head connectors for durability One-year Warranty TRANSILLUMINATOR (Head Only) 5qty (Compatible w/All existing Welch Allyn 3.5V power handles) Uses a Halogen HPX lamp Provides 30% more light output for true tissue color Consistent, long-lasting illumination Cool distal fiber-optic light transmission Fully sterilizable either with steam, gas, or liquid solutions One-year Warranty 006 DIRECT OPHTHALMOSCOPE (Head Only) - -5qty (Compatible w/All existing Welch Allyn 3.5V power handles) Coaxial Ophthalmoscope Head Halogen HPX lamp illumination for true tissue color 18 unique aperture/filter combinations Crossed-linear polarizing filter virtually eliminates corneal reflection Includes a red-free filter to be used with all apertures 68 lenses in single-diopter steps for precise resolution (+38 to -30) Illuminated lens dial clearly identifies settings Compatible with all existing Welch Allyn 3.5 V power handles Handle not included Must have a one year warranty DIRECT OPHTHALMOSCOPE (Head Only) 5qty (Must be Compatible w/All existing Welch Allyn 3.5V power handles) 2.8x the brightness and superior streak quality versus the standard for quicker refractions Optional crossed-linear polarizing filter removes 99% of glare from trial lenses Sealed optics keep dust out and optics clean for a more effective exam External focusing sleeve offers continuous rotation Converts to a spot retinoscope by replacing streak lamp with spot lamp DIGITAL ACUITY SYSTEM (Wall Mounted) 5qty All in one acuity system 24 in resolution, LED backlit display Cool running, free of fans or hard drives Astigmatic testing Standard: 17 Letter Set, 8 Letter Set, Sloan, Tumbling E, Landolt CO, Landlot HOTV, Numbers Children s: Kolt, Children s Shapes, Allen, Pediatric fixation cartoon video Presentation: Single Line, Double Same, Double Decreasing, Triple Same, Triple Decreasing, Quadruple Same, Quadruple Decreasing, Single Letter, Column, Column Uneven Other: Xcy Crowding Dots, Astigmatic Wheel, T, Fixation Dot, Horizontal Disparity, Vertical Disparity, Worth 4-Dot, Crowding Bar, Suppression, Red/Green Filter CHAIR GLUIDE SYSTEM (ADA Compliance) 5qty ( Must be Compatible w/most Reliance round and square based exam power chairs) Comply with the mandatory requirements of the Americans with Disabilities Act. Potential tax advantages with your financial professional Allows the practitioner to slide the existing chair back to accommodate wheelchairs. Steel carriage fits most Reliance chairs. The satin finished, stainless steel base plate works on any floor surface Centered on the plate, a painted stainless-steel track guides the carriage and prevents lateral movement. Heavy-duty stop limits the distance of travel; the track is tapered for better patient access. Slimline chair track provides maximum access to the patient Track tapers into a 6 tail, which allows the practitioners to move an examination stool closer to the chair to provide greater accessibility to the patient. Case hardened steel rollers enable the practitioner to effortlessly slide chair out of the way and replace it with a wheelchair Prevents lateral movement. Heavy-duty stops on the base plate limit the distance of travel. Range of travel is 27 foot lever activates and releases a friction lock that secures the chair in position anywhere along its 27 path Base plate length: 52 overall, Wide section: 28 , Narrow: 24 Base plate width: wide section: 20 ; narrow: 6 Track: 3/4 wide x 3/16 high x 52 long. Overall carriage length: 29 Overall carriage width: 26 APPLINATION TONOMETER 5qty (Must be Compatible w/Haag-Streit BQ/BP Slit Lamps) The BQ type applanation tonometer must fit the Haag-Streit slit lamps BQ 900 and BP 900 It provides a parking position and can be easily be moved into place for working The applanated surface is observed monocularly through the right eyepiece of the stereo microscope. Delivery shall be provided no later than 100 days after receipt of order (ARO). IAW with FAR 52.247-34 F.O.B. Destination Place of Delivery Address: Phoenix VA Health Care System 650 East Indian School Rd Phoenix, AZ Postal Code: 85012 Country: UNITED STATES The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html. The following solicitation provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Items . (July 2021) FAR 52.212-3, Offerors Representations and Certifications Commercial Items (July 2021) Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Items. If paragraph (j) of the provision is applicable, a written submission is required. The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Items October 2018 FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders October 201 The following subparagraphs of FAR 52.212-5 are applicable: Please see attachment A for all clauses and provisions related to this solicitation All quoters shall submit the following: Quotes (VIA EMAIL ONLY MAIL IN QUOTES WILL NOT BE ACCEPTED) Brochures of the equipment offered in their quote All quotes shall be sent to Nick Price at Nicholas.Price@va.gov Subject head: RFQ 36C25821Q0348 The last day for Questions is August 25,2021 at 5:30 PM PST Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. The following are the decision factors: The award will be given to the vendor who provides the lowest price and meets all requested salient characteristics. The award will be made to the response most advantageous to the Government. Responses should contain your best terms, conditions. To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows: ""The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition."" OR ""The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:"" Quoters shall list exception(s) and rationale for the exception(s), if any. Submission of your response shall be received not later than the closing date of 8/30/2021 at 5:30 PM PST Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Point of Contact Nick Price Nicholas.Price@va.gov Phone calls will not be returned all questions must be submitted in writing.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/df66f2c023944dd5b518f5aff52838ad/view)
- Place of Performance
- Address: Department of Veterans Affairs Phoenix VA Health Care System Warehouse 650 East Indian School rd, Phoenix 85012
- Zip Code: 85012
- Zip Code: 85012
- Record
- SN06102306-F 20210820/210818230125 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |