Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 26, 2021 SAM #7208
MODIFICATION

Z -- Correct Trash Chute Rooms BLDG 1

Notice Date
8/24/2021 7:05:51 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24621Q1245
 
Response Due
9/23/2021 12:00:00 PM
 
Archive Date
12/31/2021
 
Point of Contact
Nicholas J Ruppert, Contract Specialist
 
E-Mail Address
nicholas.ruppert@va.gov
(nicholas.ruppert@va.gov)
 
Awardee
null
 
Description
Page 4 of 4 RESOLICITATION NOTICE Project #558-21-107 Correct Trash Chute The Department of Veterans Affairs, 508 Fulton Street Durham, NC has a requirement for a contractor to provide all labor, material, supplies, equipment, transportation, permits, license and qualified supervision for Project 558-21-107, to Correct the Trash Chute in Building 1, Durham VAMC 508 Fulton Street Durham, NC. General Scope: The Contractor will provide all transportation, material, hardware, parts, tools, specialized equipment, labor, supervision and technical expertise to Correct Trash Chute. Work shall include, but not be limited to: Rooms C1003, C2007, C3009, C4019, C5009, C6007, C7009, C8007, C9007, and C10017 Repair penetrations to rated walls via dry-wall repair, patching, application of fire caulking. Apply elastomeric fire stop in transition joint areas. Install new impact resistant and waterproof wall cladding system on all walls. Coverings shall extend from the finished floor to a minimum of four inches above to the acoustical ceiling tile. Replace cove base material and install wall guard. Wall cladding and protection system shall be from a single manufacturer. Replace all chute doors, chute door frames, and closure devices. Install electrical locking system to limit one trash and one linen chute door to be opened at a single time. New doors, hardware, and devices shall meet Accessibility and Fire Rating requirements as indicated in the Life Safety drawing excerpts attached. Replace acoustical tile ceiling and track system with new. Maintain existing sprinkler system. Install new floor mounted door stops and door Replace up to 960 square feet of non-compliant dry wall with rated dry wall as indicated in the Life Safety drawing excerpts attached. Provide separate line item cost in schedule of values for dry wall replacement reserve. Contractor shall conduct limited dry wall coring in areas identified by COR in order to verify compliance with wall rating. Maintain existing room functionality not otherwise referenced in scope of work. Room CG003 Demolish all interior existing walls from finished floor to decking above and install rated walls as indicated in the Life Safety drawing excerpts attached. Install new impact resistant and waterproof wall cladding system on all walls. Coverings shall extend from the finished floor to a minimum of four inches above the acoustical ceiling tile. Install new cove base, corner and wall guards. Corner guards to be installed on all outside corners. Wall cladding and protection system shall be from a single manufacturer. Replace acoustical tile ceiling and track system with new. Replace existing ceiling mounted air outlets with new. Maintain existing sprinkler system. Replace linen chute door, chute door frame, and closure device. Fabricate chute door support sufficient to maintain door in the open position without creating penetration in acoustical ceiling tile. Install new stainless-steel chains and fusible links. Fabricate chute door support sufficient to maintain trash chute door in the open position without creating penetration in acoustical ceiling tile. Install new stainless-steel chains and fusible links. Demolish existing floor covering to original concrete decking. Install new epoxy floor covering system. Slope floor to achieve positive drainage to the existing drain locations. Replace all drain and cleanout covers in the space and reapply sealant to ensure proper water proofing. Install new wall mounted hose bib, coordinate location with VA COR. Cut and cap existing water line beneath finished wall surface. Replace existing electrical panel with NEMA 4X panel. Demolish existing power receptacles and replace with covered GFCI receptacles rated for wet locations. Reinstall new receptacles four feet above finished flooring. Replace all existing electrical fixtures with fixtures rated for wet location. Maintain existing room functionality not otherwise referenced in scope of work. Maintain existing room functionality not otherwise referenced in scope of work. Estimated construction magnitude is between $100,000 and $250,000 NAICS CODE: 236220 Size Standard: $39.5 Million This solicitation is anticipated to be full and open competition. The solicitation will be open to all business types. Solicitation material will be available on/about August 24, 2021. Any specifications, drawings and amendments will be posted on this web site. Proposals will be due approximately 28 days after issuance of the solicitation. Location and points of contact for site visits will be identified in the solicitation. This notice is for informational purposes only and is not a request for proposals. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No bidders list is maintained. All interested vendors should register on this website. It is the offerors responsibility to check the web site periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the System for Award Management (SAM) database in order to obtain access in SAM. SAM must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to Nicholas.Ruppert@va.gov. NO TELEPHONE REQUEST FOR BIDDING MATERIAL WILL BE ACCEPTED.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/c4883fa5f81e4a188d9264499fedcab8/view)
 
Record
SN06107922-F 20210826/210824230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.