SOLICITATION NOTICE
J -- Dredge Vessel Essayons Overhaul
- Notice Date
- 8/25/2021 7:41:33 AM
- Notice Type
- Solicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- US ARMY ENGINEER DISTRICT PORTLAND PORTLAND OR 97204-3495 USA
- ZIP Code
- 97204-3495
- Solicitation Number
- W9127N21B0025
- Response Due
- 9/22/2021 11:00:00 AM
- Archive Date
- 10/07/2021
- Point of Contact
- Carl Schmurr, Pat Collins
- E-Mail Address
-
carl.r.schmurr@usace.army.mil, patrick.p.collins@usace.army.mil
(carl.r.schmurr@usace.army.mil, patrick.p.collins@usace.army.mil)
- Description
- Edit 24-AUG-2021: USACE - Safety and Health Requirements Manual�EM 385-1-1 has been attached to the attachments. The U.S. Army Corps of Engineers (USACE), Portland District, intends to award a firm fixed price Job Order under a Master Ship and Repair Agreement (MSRA) for overhaul, maintenance, and repair of Dredge ESSAYONS. Major work items that may be associated with the overhaul and dry docking can be found at the bottom of this announcement. The complete list can be found within the attached invitation for bid (IFB). SITE VISIT (Ship visit): For a Contractor to be determined responsible and eligible for award, a representative of the contractor MUST attend one of the available site visits. The dates for the site visits are: Wednesday August 25 Wednesday September 1 Wednesday September 8 Wednesday September 15 Site visits will be in the Columbia River area.� If a Contractor would like to request a different day to meet their travel requirements, that can be arranged with 7 days of advance notice.� Due to the current Potable Water capacity the vessel is making pier stops approximately every 10-12 days.� Any of these pier stops could be used as an opportunity for a Ship Check without impacting the vessel schedule. The actual pick up locations will be confirmed within 5 days of each visit, with these visits intended to be�no more than 90 minutes away from Portland, OR. Site visits will begin promptly at 9:00 AM Pacific Time. All offerors will be required to wear Personal Protective and Safety Equipment (PPE) that meet the requirements of EM 385-1-1. PPE WILL NOT be provided by USACE. Offerors are expected to bring their own PPE to the site visit. Standard COVID protocol will be followed, as required by the State.� Face coverings will be required, and temperature checks will be done upon arrival. The Dredge ESSAYONS is currently in the operational dredge season throughout the Columbia River. Due to the current operational schedule, the details for the locations of the site visit dates above are subject to change. To schedule a site visit, please contact Mr. Carl Schmurr at�Carl.R.Schmurr@usace.army.mil�and Mr. Pat Collins at�Patrick.P.Collins@usace.army.mil. Some of the potential site visit locations will require a Transportation Worker Identification Certification (TWIC) card to obtain entry. If you do or do not have a TWIC card, please make the Point of Contact (POC) below aware of this information when scheduling the site visit. For those who do not have a TWIC card, an escort will be arranged for pick up from outside of the Port entry point. Prospective contractors must have, or be capable of, entering into a MSRA with USACE, Portland District. Every prospective contractor that wishes to be considered for the award of the job order from the IFB must have an active MSRA for overhaul of the ESSAYONS with USACE, Portland District. If a prospective contractor wishes to submit a bid for this job order and has not already entered into a MSRA for overhaul of the ESSAYONS with Portland District, then please contact Mr. Carl Schmurr at�Carl.R.Schmurr@usace.army.mil�and Mr. Pat Collins at�Patrick.P.Collins@usace.army.mil. This IFB is issued on a full and open competition basis in electronic format only. Paper copies of this IFB will not be available. Other methods of requesting a package will not be accommodated. Bidders shall submit their bids via email to the following individuals by no later than the date and time established in Block 9 of the Standard Form (SF) 33, or Block 14 of the most recently issued SF 30 as applicable: Pat Collins, Contracting Officer�Patrick.P.Collins@usace.army.mil. Carl Schmurr, Contract Specialist�Carl.R.Schmurr@usace.army.mil Each email shall contain the following information: Solicitation No. W9127N21B0025 Bid Due Date and Time:� ______ Bid Validity Date:� ______ (90 days from the bid due date) NOTE:� Additional submission instructions are included in the SF 33. Any prospective Offeror must first register in the System for Award Management (SAM) at www.sam.gov. After completing SAM registration, interested Contractors and their Subcontractors must then register at https://www.beta.sam.gov in order to obtain solicitation documents, including plans and specifications. It is the contractor's responsibility to monitor beta.sam.gov for any amendments to the IFB. The NAICS Code is 336611; PSC Code J999. Dredge ESSAYONS Description: Dredge ESSAYONS is a trailing arm suction hopper dredge built in 1984. It has the following Characteristics: Length Overall 350 Feet Length between perpendiculars 333 Feet Beam Molded 68 Feet Beam Overall (With Drag Arms Lowered) 108 Feet Registered Gross Tonnage 7,248 Long Tons Normal Light, Draft Forward 19'-0"" Normal Light, Draft Aft 21'-0"" Class ABS Loadline Anticipated major work items to be included in the job order are as follows: Transportation Tug Services Crane Services Connection/Disconnection of Services Field Office Parking Drydock Lift and Lay Days Wet Berth Electricity Steam Marine Chemist Certificates Fire Suppression Services Bilge Maintenance Lower Hull - Zinc Coat Coatings Upper and Lower Hull - Anti Corrosive Coat Coatings Upper and Lower Hull - Final Coat� Coatings Lower Hull - Anti Foulant Coat Irathane 155 Urethane Coating Hull Degreasing Hull Fire Hose Washing Hull 10,000 PSI Water Washing Hull Zinc Anode Renewal Sluice Valve Replacement/Overhaul Hopper Jetting Gate Valve Main Sea Strainer Repairs Drag Wire Replacement Purchase Drag Wires Dragarm Sheave Inspection Discharge Piping Inspection Hopper Jetting System Cleaning Weir Seal Replacement Hopper Inspection Staging Tower Staging Propeller Blade Inspection/Replacement Propeller Hub Replacement Tailshaft Replacement Stern Tube Shaft Seal Replacement Bow Thruster - Lower Gearbox LGB/Pod Change Out ABS Support Audio Gauge Reading Elevator Inspection and Repair Anchor Chain Locker Reconditioning Life Raft Annual Service Sludge Tank Annual Maintenance Strut and Stern Tube Bearing Inspection Rudder Bushing Clearance Documentation Dock and Sea Trials ALMO Pipe Chute and Lower Pump Room Dredge Pipe Removal Main Pedestal Crane Replacement
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/c65047d48cdf4f76bdb1fbb516a3a44d/view)
- Record
- SN06110449-F 20210827/210825230128 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |