SOLICITATION NOTICE
J -- Dredge Vessel Yaquina Overhaul
- Notice Date
- 9/1/2021 9:41:47 AM
- Notice Type
- Solicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- US ARMY ENGINEER DISTRICT PORTLAND PORTLAND OR 97204-3495 USA
- ZIP Code
- 97204-3495
- Solicitation Number
- W9127N21B0026
- Response Due
- 9/22/2021 11:00:00 AM
- Archive Date
- 10/07/2021
- Point of Contact
- Carl Schmurr, Pat Collins
- E-Mail Address
-
carl.r.schmurr@usace.army.mil, patrick.p.collins@usace.army.mil
(carl.r.schmurr@usace.army.mil, patrick.p.collins@usace.army.mil)
- Description
- 01-SEPT-2021: Contract Price Schedule added to attachments list. 27-AUG-2021: Drawings added. The U.S. Army Corps of Engineers (USACE), Portland District, intends to award a firm fixed price Job Order under a Master Ship and Repair Agreement (MSRA) for overhaul, maintenance, and repair of Dredge YAQUINA. Major work items that may be associated with the overhaul can be found at the bottom of this announcement. The complete list can be found within the attached invitation for bid (IFB). SITE VISIT (Ship visit): For a Contractor to be determined responsible and eligible for award, a representative of the contractor MUST attend one of the available site visits. The dates for the site visits are: 24-AUG-2021�at the NOAA pier in NEWPORT, OR� 07-SEPT-2021�at the NOAA pier in NEWPORT, OR. 14-SEPT-2021 on the Columbia River. This is a backup date with pier transport location TBD. Coordinate early with Contract Specialist if you know you will require the 14-SEPT date.�� Site visits will begin promptly at 9:00 AM Pacific Time. All offerors will be required to wear Personal Protective and Safety Equipment (PPE) that meet the requirements of EM 385-1-1. PPE WILL NOT be provided by USACE. Offerors are expected to bring their own PPE to the site visit. Standard COVID protocol will be followed, as required by the State.� Face coverings will be required, and temperature checks will be done upon arrival. The Dredge YAQUINA is currently in the operational dredge season throughout the Columbia River. Due to the current operational schedule, the details for the locations of the site visit dates above are subject to change. To schedule a site visit, please contact Mr. Carl Schmurr at Carl.R.Schmurr@usace.army.mil and Mr. Pat Collins at Patrick.P.Collins@usace.army.mil. Some of the potential site visit locations will require a Transportation Worker Identification Certification (TWIC) card to obtain entry. If you do or do not have a TWIC card, please make the Point of Contact (POC) below aware of this information when scheduling the site visit. For those who do not have a TWIC card, an escort will be arranged for pick up from outside of the Port entry point. Prospective contractors must have, or be capable of, entering into a MSRA with USACE, Portland District. Every prospective contractor that wishes to be considered for the award of the job order from the IFB must have an active MSRA for overhaul of the YAQUINA with USACE, Portland District. If a prospective contractor wishes to submit a bid for this job order and has not already entered into a MSRA for overhaul of the YAQUINA with Portland District, then please contact Mr. Carl Schmurr at Carl.R.Schmurr@usace.army.mil and Mr. Pat Collins at Patrick.P.Collins@usace.army.mil. This IFB is issued on a full and open competition basis in electronic format only. Paper copies of this IFB will not be available. Other methods of requesting a package will not be accommodated. Bidders shall submit their bids via email to the following individuals by no later than the date and time established in Block 9 of the Standard Form (SF) 33, or Block 14 of the most recently issued SF 30 as applicable: Pat Collins, Contracting Officer Patrick.P.Collins@usace.army.mil� Carl Schmurr, Contract Specialist Carl.R.Schmurr@usace.army.mil� Each email shall contain the following information: Solicitation No. W9127N21B0026 Bid Due Date and Time:� ______ Bid Validity Date:� ______ (90 days from the bid due date) NOTE:� Additional submission instructions are included in the SF 33. Any prospective Offeror must first register in the System for Award Management (SAM) at www.sam.gov. After completing SAM registration, interested Contractors and their Subcontractors must then register at https://www.beta.sam.gov in order to obtain solicitation documents, including plans and specifications. It is the contractor's responsibility to monitor beta.sam.gov for any amendments to the IFB. The NAICS Code is 336611; PSC Code J999. Dredge YAQUINA Description: Dredge YAQUINA is a trailing arm suction hopper dredge built in 1984. It has the following Characteristics: Length Overall 200 Feet Length between perpendiculars 188 Feet Beam Molded 58 Feet Beam Overall (With Drag Arms Lowered) 70 Feet Registered Gross Tonnage 2,100 Long Tons Normal Light, Draft Forward 6'-7"" Normal Light, Draft Aft 10'-3"" Class ABS Loadline Anticipated major work items to be included in the job order are as follows: Transportation Tug Services Crane Services Connection/Disconnection of Services Field Office Parking Wet Berth Electricity Steam Marine Chemist Certificates Fire Suppression Services Bilge Maintenance Lower Hull - Zinc Coat Coatings Upper and Lower Hull - Anti Corrosive Coat Coatings Upper and Lower Hull - Final Coat� Coatings Lower Hull - Anti Foulant Coat Irathane 155 Urethane Coating Hull Degreasing Hull Fire Hose Washing Hull 10,000 PSI Water Washing Hull Zinc Anode Renewal Sluice Valve Replacement/Overhaul Hopper Jetting Gate Valve Main Sea Strainer Repairs Drag Wire Replacement Purchase Drag Wires Dragarm Sheave Inspection Discharge Piping Inspection Hopper Jetting System Cleaning Weir Seal Replacement Hopper Inspection Staging Tower Staging Propeller Blade Inspection/Replacement Propeller Hub Replacement Tailshaft Replacement Stern Tube Shaft Seal Replacement Bow Thruster - Lower Gearbox LGB/Pod Change Out ABS Support Audio Gauge Reading Elevator Inspection and Repair Anchor Chain Locker Reconditioning Life Raft Annual Service Sludge Tank Annual Maintenance Strut and Stern Tube Bearing Inspection Rudder Bushing Clearance Documentation Dock and Sea Trials ALMO Pipe Chute and Lower Pump Room Dredge Pipe Removal Main Pedestal Crane Replacement Transportation Crane Services Tug Service Field Office Parking Wet Berth Services Wet Berth Lay Days Electricity Steam Compressed Air Sanitation Potable Water Internet Connection/Disconnection of Services Pump Room Bilge Cleaning Engine Room Bilge Cleaning Slops Tank Annual Maintenance Pressure Wash Exterior Hull Coating Weather Decks Coating Aluminum House Hull Anode Renewal Hopper Inspection Staging Sluice Valve Replacement Sliding Piece Fit-Up Bow Thruster-Inspection Setup Bow Thruster- Inspection, Oil and Seal Change Life Raft Annual Service Clean and Inspect Galley Exhaust Duct Fire Suppression Services Annual Rescue Boat Davit Maintenance Dock and Sea Trials Navigation Equipment Service Emergency Generator Service CRPP Control Service Coating of Hull Above Waterline Coating of Hull Below Waterline Hopper Door Hydraulic Cylinder Repairs Hopper Overflow Hydraulic Cylinder Overhaul 20-Inch Pipe Replacement Hopper Door Hinge Bushing Renewal Bow Thruster- Pod Preservation Main Propulsion System- Shaft Bearing Clearances HVAC- Engine Room Exhaust Fan Overhaul HVAC- Auxiliary Machinery Room Supply or Exhaust Fan Overhaul House Main HVAC Supply Fan Overhaul Chain Locker and Ballast Tank Cleaning Anchor and Anchor Chain Reconditioning Suction Inlet Hull Rings and Pipe Liners Replacement Swell Compensator Cylinder Overhaul Draghead Winch Reconditioning Gimbal Winch Reconditioning Hopper Door Operating Rod Replacement Hopper Door Bearing Support Channel Overhaul Bow Thruster- Sleeve Replacement Main Propulsion System-Propeller Blades Replacement Main Propulsion System-Tailshaft/Hub Assembly Replacement Main Propulsion System- Shaft Bearing Replacement Aft Fire Pump Overhaul Steering System- Rudder Assembly Replacement Steering System- Steering Gear Overhaul HVAC- Engine Room Supply Fan Overhaul HVAC- Pump Room Supply Fan Overhaul HVAC- Pump Room Exhaust Fan Overhaul Internal Tank Inspection Skin Valves and Sea Strainers Inspection Engine Services House Flooring Renewal Cross flood tank Air & CO2 Room Coatings Bilge System Piping Replacement Pump Room Bilge & Ballast Manifold Replacement King Post Renew Stern Tube Boot Replacement Potable Water Chlorinate Shaft Knife Replacement Fuel Tank Overflow Pipe Modification Annual Launch Davit Maintenance Watertight Door Installation HVAC Duct Cleaning Fire Main Piping Replacement
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/4d662af669eb42d3acfd3f09748ea592/view)
- Record
- SN06119179-F 20210903/210901230121 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |