Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 04, 2021 SAM #7217
SOLICITATION NOTICE

Z -- 36C24821R0176 - Z1DA--NRM Tier 2 (PROJ: 573-CSI-104) BB - Renovate Radiology for for Equipment Installation - Solicitation

Notice Date
9/2/2021 11:00:06 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24821R0176
 
Response Due
9/13/2021 10:00:00 AM
 
Archive Date
11/12/2021
 
Point of Contact
Amber Milton, Contracting Officer
 
E-Mail Address
amber.milton@va.gov
(amber.milton@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Amendment 0003 to incorporate the following changes: 1. EDIT SUBJECT to match the solicitation system errorZ1DA--NRM Tier 2 (PROJ: 573-CSI-104) BB - Renovate Radiology for for Equipment Installation - Solicitation 2. EDIT PSC CODE changes in system�from Y1DA Construct�Hospitals and infirmaries to�Z1DA- Maintenance of Hospitals and Infirmaries. all other terms remain the same.� 3. CHANGE�POP from 540 days from NTP�to 365 days from NTP . 4. PROVIDE SITE VISIT SIGN IN SHEET� 5. PROVIDE UPDATED SPECS 01 00 00 GENERAL CONDITIONS 6.�Change Deductive bid items. REMOVE�ITEM II (BID DEDUCT ALTERNATE NO. 1): Provide all Work described in ITEM I except modify the following items: Reduce the number of 2nd floor deck penetrations for return air ducts at rooms Angio #1 and Angio #2. Submit proposed duct consolidation plans that are the basis for the deduct amount. These plans must be coordinated with all other work occurring between the room ceilings and the deck, for review by the VA to help determine the Alternate�s acceptance or not. Contract Duration is 540 calendar days after the NTP PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction PRODUCT/SERVICE CODE: Z1DA - Maintenance of Hospitals and Infirmaries REPLACE WITH�ITEM II (BID DEDUCT ALTERNATE NO. 1): Deduct Angio Room 104 and Equipment Room 105 from the scope of the project as noted below: Perform required demolition in this area but do not provide interior wallboard (leave metal studs exposed), ceilings, finishes, nor equipment in Angio Room 104. Perform required demolition in this area but do not provide interior wallboard (leave metal studs exposed), ceilings, finishes, nor equipment in Equipment Room 105. Provide the door and viewing window of the Shared Control Room 106.� All finishes and elements required for Shared Control Room 106 will be complete as viewed from inside the control room. Construct and complete the wall and door to the Elevator Lobby so that it is finished when viewed from the elevator lobby. Install the double doors from Angio Room 104 to Corridor 103 with associated door controls and hardware. Where plumbing mains or branch piping (CW, HW, HW recirculation, steam, sanitary waste and vent, medical gas piping, etc.) pass through the noted deduction area and serve other areas outside of the deducted area these elements must be included in the base bid such that no elements outside of the deduct area are left inoperable. Do not provide scheduled lighting, power or systems work in this area except stub conduit scheduled to serve this area with pull strings back to the next junction box or panel outside of the deduct area. Provide life safety lighting in lieu of scheduled lighting to maintain minimum of ten foot-candles of light in the area. Construct supply air openings (Note 3 and 7 on Drawing M-201) for supply air ducts to second level mechanical room and close openings with fire rated damper.� Construct return air duct openings (Note 6, 15 and 20 on Drawing M-201) to second level mechanical room and close openings with fire rated damper. Ductwork on the second level is to be completed and penetrate the first-floor space at least twelve inches.� Cap open end of ductwork. Provide required fire protection mains, branch lines and piping to sprinkler heads except turn sprinkler heads up to deck as required to cover shelled area in accordance with NFPA requirements. Contract Duration is 365�calendar days after the NTP PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction PRODUCT/SERVICE CODE: Z1DA - Maintenance of Hospitals and Infirmaries ** HOUR & DATE for Receipt of Offers is� SEPTEMBER 13, 2021� @ 1:00pm est
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/6d3e1361b15b4503895f5581261558fe/view)
 
Place of Performance
Address: Gainesville, FL 32608, USA
Zip Code: 32608
Country: USA
 
Record
SN06120875-F 20210904/210902230130 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.