AWARD
D -- IN ACCORDANCE WITH INQUIRY HC101321QA469, PROCEED TO PROVIDE, INSTALL, AND MAINTAIN A 10GB CIRCUIT BETWEEN BLDG 3147, RM 1L4.1, 1050 REMOUNT RD, NORTH CHARLESTON, SC, 29406 AND BLDG 228, DEMARK RM, 1ST FL, 205 PERRY ST, ROBINS AFB, GA 31098
- Notice Date
- 9/8/2021 10:17:47 AM
- Notice Type
- Award Notice
- NAICS
- 517311
— Wired Telecommunications Carriers
- Contracting Office
- TELECOMMUNICATIONS DIVISION- HC1013 SCOTT AFB IL 622255406 USA
- ZIP Code
- 622255406
- Solicitation Number
- HC101321QA469
- Archive Date
- 03/08/2022
- Point of Contact
- JOHN WARNER, Phone: Not Applicable, Kevin Knowles
- E-Mail Address
-
john.d.warner28.civ@mail.mil, kevin.l.knowles4.civ@mail.mil
(john.d.warner28.civ@mail.mil, kevin.l.knowles4.civ@mail.mil)
- Award Number
- HC101321PA501
- Award Date
- 09/08/2021
- Awardee
- GTT GLOBAL TELECOM GOVERNMENT SERVICES, LLC
- Award Amount
- 134546.70
- Description
- 1. IN ACCORDANCE WITH INQUIRY HC101321QA469, PROCEED TO PROVIDE, INSTALL, AND MAINTAIN A 10GB CIRCUIT BETWEEN BLDG 3147, ROOM 1L4.1, 1050 REMOUNT ROAD, NORTH CHARLESTON, SC, 29406, JOINT BASE CHARLESTON, CHARLESTON, SC 29406/CCI AND BLDG 228, DEMARK ROOM, 1ST FLOOR, 205 PERRY STREET, ROBINS AFB, GA 31098/CCI. THE PROPOSED AND APROVED RTD IS: LESS THAN OR EQUAL TO 10 MILLISECONDS . ANY CHANGES TO THE RTD AFTER AWARD ARE NOT ACCEPTABLE. A. THIS REQUIREMENT SUPPORTS MPLS AND WILL REPLACE CCSD: BDA5 2. THE SERVICE DATE TO BE MET IS: 07 DEC 2021 (SIP). THE GOVERNMENT WILL ASSESS CONSIDERATION IAW STANDARD PROVISION 42 FOR DELAY ON DELIVERY OF CIRCUIT ON CONTRACTED SERVICE DATE. 3. ESTABLISH TSP: TSP0L48PY-01 4. SEE ATTACHMENTS AND UNIQUE INSTALLATION FACTORS FOR TECHNICAL REQUIREMENTS SPECIFIC TO THIS ORDER. 5. CONTRACTOR MUST UPLOAD NOTICE OF COMPLETION IN IDEAS. 6. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH INQUIRY HC101321QA468 /TSR RU29JUN217213 AND MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS (SDP) FROM INQUIRY HC101321QA469 / TSR RU29JUN217214; MEANING THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM INQUIRY HC101321QA468 /TSR RU29JUN217213.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/76b9ddbae3a243be9a87180ef77b2a4a/view)
- Record
- SN06124443-F 20210910/210908230121 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |