Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 15, 2021 SAM #7228
SOLICITATION NOTICE

J -- HEAT PUMP REPLACEMENT AT THE NATIONAL MARINE FISHERIES SERVICE�S SANTA CRUZ LABORATORY IN SANTA CRUZ, CA.

Notice Date
9/13/2021 1:59:53 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
DEPT OF COMMERCE NOAA SEATTLE WA 98115 USA
 
ZIP Code
98115
 
Solicitation Number
NFFR75002103004NGB
 
Response Due
9/16/2021 12:00:00 PM
 
Archive Date
10/01/2021
 
Point of Contact
Nicholas G. Brown, Phone: 3034976349
 
E-Mail Address
nicholas.g.brown@noaa.gov
(nicholas.g.brown@noaa.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
***PLEASE SEE ATTACHMENTS FOR COMPLETE DETAILS*** NO QUOTE FORM WILL BE PROVIDED. PLEASE SUBMIT PRICING/TECHNICAL PROPOSAL ON YOUR OWN FORM. THE OFFEROR MUST BE CURRENLTY REGISTERED IN THE SYSTEM AWARD MANAGEMENT (SAM) TO BE ELGIBLE FOR AN AWARD. QUOTES WILL BE EVALUATED BASED ON FAR 52.212-2 IN ATTACHED CLAUSES & PROVISIONS. *VENDORS MUST COMPLETE SECTION (c) OF PROVISION FAR 52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO SURVEILLANCE SERVICES OR EQUIPMENT (AUG 2020) WHICH IS INCLUDED IN THE PROVISIONS SECTION OF THE COMBINED SYNOPSIS, UNLESS YOUR REPS AND CERTS HAVE BEEN UPDATED TO INCLUDE 52.204-26(OCT 2020). TO SCHEDULE A SITE VISIT, PLEASE CONTACT TOM RAUSCH: Name: Tom Rausch, Facility Manager Email: tom.rausch@noaa.gov Phone: 831-420-3901 SCLS Wage Determination 2015-5649 Rev 12 8/3/2021 is applicable to this RFQ. ???????DESCRIPTION OF WORK: Background/Overview: The SWFSC Santa Cruz Laboratory at 110 McAllister Way, Santa Cruz, CA facility contains several experimental labs, sensitive scientific equipment, boats, offices, conference rooms and a library. The facility has space for about 120 scientists and support staff. Recently, the lab experienced problems with the condenser water loop which supports all appliances that run on refrigeration such as the 60K chiller and the 21 water source heat pumps. Upon repair of the condenser loop, heat pump 2-8 was identified as requiring replacement as well. Scope of Work Heat pump 2-8 is a 3 ton water source heat pump that services the MDF server room at the Santa Cruz Laboratory. This unit is wired on the emergency generator power and is heavily relied upon during power outages. The contractor shall replace and install a new Trane GEVE036 water source heat pump with: 3 ton nominal cooling, 410 refrigeration, high static blower, two way valve assembly with actuator motor. Tasks Task 1: Remove and dispose of old heat pump 2-8. Task 2: Furnish and install new Trane GEVE036 water source heat pump with 3 ton nominal cooling, 410 refrigeration, high static blower, two way valve assembly with actuator motor. Task 3: Reroute and connect existing water piping and repair where needed. Task 4: Install new 2 way B&G reducing valve assembly with new floating Honeywell actuator 24VDC motor. Task 5: Connect condensate pipe to existing drain lines and repair where needed. Task 6: Charge refrigeration, connect power, run and test to ensure new heat pump 2-8 is fully operable and replacement is complete.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/cf61827f92b347a4878d36ee718378e9/view)
 
Place of Performance
Address: Santa Cruz, CA 95060, USA
Zip Code: 95060
Country: USA
 
Record
SN06130478-F 20210915/210913230123 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.