Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 15, 2021 SAM #7228
SOURCES SOUGHT

J -- Service: PM SPS Sterilizers

Notice Date
9/13/2021 10:09:24 AM
 
Notice Type
Sources Sought
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24821Q1711
 
Response Due
9/16/2021 8:00:00 AM
 
Archive Date
10/01/2021
 
Point of Contact
Rafael A Rodriguez, Rafael Rodriguez, Phone: 787-781-8700
 
E-Mail Address
Rafael.Rodriguez2@va.gov
(Rafael.Rodriguez2@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
SCOPE: THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION Only. Provide all labor, equipment and materials for the preventive and corrective maintenance of the systems hardware and software included under schedule A (item 1.2) herein located in the VA Caribbean Healthcare System (San Juan & Mayaguez OPC) for the period of one Base year and four years option period, in accordance with the following conditions: Perform all inspections and maintenance services in accordance to manufacturer s service manual instructions and procedures for preventive and corrective maintenance. Thorough inspection of equipment to detect defective components capable of adversely affecting system performance. Replacement of parts found defective during inspections. Contractor will repair or replace the system component with New Original Equipment Manufacturer (OEM) parts or software, not to exceed 3 business days. Part s values will be assessed by the Getinge USA, Inc. and Department of Veterans Affairs Federal Supply Schedule Contract V797P-4452b or most current contract. Cleaning, calibration and adjustment of components to maintain equipment within manufacturer s specifications, level of performance and accuracy. Operational tests after each corrective and preventive maintenance service to assure level of performance is within specifications. Contractor shall perform quarterly inspections, conduct quality control tests and verify internal parameters to the steam sterilizers. If required, the equipment will be calibrated to conform to manufacturer s specifications. Contractor shall perform quarterly preventive maintenance services per system in accordance with manufacturer s recommendations and procedures. If updates to manufacturer s requirements and/or recommendations occur, contractor must assure compliance with these requirements. Service personnel must have been trained and certified for service and maintenance of the equipment models included in this service contract. Steam Sterilizer chamber will be deep cleaned by contractor quarterly per year. Contractor will provide and install any software update, patches and enhancement intended to update system software version or correct software errors and deficiencies. Contractor shall supply all labor, parts, transportation, test instruments, tools, hardware and software required to perform all maintenance and repair work under schedule A (item 1.2). Unlimited on-site service and technical support, including calls can be performed during regular hours, 8:00AM to 5:00PM. The on-site response time to emergency calls for service will be no more than four (4) hours after notification. There will be an end user 24/7 Customer Support Help Line to address any equipment malfunction issue that may arise after hours during the everyday use of the equipment. In the event that problem cannot be resolved by telephone support, a trained service technician will provide on-site service within 24 hours to solve the malfunction and return equipment back to manufacturer specifications. Contractor s service personnel shall report to the designated COR or the Biomedical Supervisor at the Biomedical Engineering Section Room C12 before and after each service request. A copy of each service report with a checklist of all tasks performed including a list of parts replaced will be provided to the designated COR or the Biomedical Supervisor at the Biomedical Engineering Section Room C12 each day at the conclusion of each service call. Major repairs due to acts of God, chamber, doors, frequency generators, renovation of equipment, negligence or misuse, power line fluctuations, and computer virus unattributable to contractor, are not covered by this contract. Schedule A: Equipment Description Manufacturer Model Serial number VA property number Location PM Schedule Quaterly Semi-Annual Annual Steam Sterilizer GETINGE 733HC-E BAA100325 65260129 SPS, VA SAN JUAN X X X Steam Sterilizer GETINGE 733HC-E BAA097060 65260126 SPS, VA SAN JUAN X X X Steam Sterilizer GETINGE 733HC-E BAA100066 65260128 SPS, VA SAN JUAN X X X Steam Sterilizer GETINGE 733HC URA050854 65230324 SPS, VA MAYAGUEZ X X X Steam Sterilizer STERIS AMSCO CENTURY V-116 0301411-20 65211367 OR, VA SAN JUAN   X X Ultrasonic Cleaner GETINGE KS2460UC KSL12082 65218089 SPS, VA SAN JUAN X X X Rinse/Dryer GETINGE KS2460RD KSL12018 65218090 SPS, VA SAN JUAN X X X Washer Disinfector GETINGE 88 TURBO W50042305 65219621 SPS, VA SAN JUAN X X X Washer Disinfector GETINGE 88 TURBO WAA075124 65233967 SPS, VA SAN JUAN X X X CART WASHER GETINGE 9127E WAA088830 65257644 SPS, VA SAN JUAN X X X Ultrasonic Cleaner GETINGE 1522 1912-1522-814-3 65253116 SPS, VA SAN JUAN X X X Responses to this notice should include company name, address, point of contact, phone number, fax number and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS). NAICS Code is 811219- Other Electronic and Precision Equipment Repair and Maintenance. This procurement will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received in writing no later than 12:00pm Puerto Rico EST on September 16, 2021. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff in regard to this requirement, as they are not authorized to discuss this matter related to this procurement action, all questions will be addressed during the solicitation stage by the Contract Specialist. All firms responding to this Request for Information are advised that their response is not a request for proposal therefore will not be considered for a contract award.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/1b9cd018eb4d429c95456c39cc847626/view)
 
Place of Performance
Address: VA Caribbean Healthcare System 10 Casia Street, San Juan PR
Zip Code: PR
 
Record
SN06131539-F 20210915/210913230130 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.