Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 25, 2021 SAM #7238
MODIFICATION

J -- Contract for gas and air compressors. 1 base year with 4 option years

Notice Date
9/23/2021 11:36:15 AM
 
Notice Type
Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
 
ZIP Code
04330
 
Solicitation Number
36C24121Q0744
 
Response Due
9/28/2021 12:00:00 PM
 
Archive Date
10/28/2021
 
Point of Contact
Jerry Choinski, Contract Specialist
 
E-Mail Address
Jerry.Choinski@va.gov
(Jerry.Choinski@va.gov)
 
Awardee
null
 
Description
THIS SOURCES SOUGHT/REQUEST FOR INFORMATION IS ISSUED FOR INFORMATION AND PLANNING PURPOSED ONLY AND IS NOT CONSIDERED A SOLICITATION. The purpose of this sources sought/RFI is to gain knowledge of businesses that are capable of fulfilling the following work requirement: SCOPE OF WORK AIR COMPRESSORS & VACUUM PUMPS PREVENTIVE MAINTENANCE & REPAIR SERVICE VAMC, PROVIDENCE, RI The contractor shall provide all equipment, labor, materials; to include tools and parts, transportation, supervision, permits and disposal necessary to perform required preventive maintenance and repair for air compressors and vacuum pumps at the VA Medical Center, 830 Chalkstone Avenue, Providence, RI 02908. PREVENTIVE MAINTENANCE The contractor shall provide quarterly preventive maintenance to 17 critical air compressors and vacuum pumps on the equipment listed below. ID Description Manufacturer Location Bldg/Unit Model Notes COMP- 011B23 CRITICAL-PUMA PUMA COMPRESSOR B-01 MAIN HOSP 1ST FLOOR LA-5706 IN SERVICE COMP- 013P15 CRITICAL COMPRESSOR CHAMPION B-01 MAIN HOSP 3RD FLOOR DM001642 IN SERVICE COMP- 018P05, 06, 07 CRITICAL COMPRESSOR POWEREX B-01 MAIN HOSP 8TH FLOOR MSH05042P5 IN SERVICE COMP- 01DB24 CRITICAL COMPRESSOR INGERSOLL RAND TWO B-01 MAIN HOSP BASEMENT CVB616930/234 0 PUMPS IN SERVICE COMP- 09B26 CRITICAL COMPRESSOR CHAMPION B-09 RESEARCH BASEMENT RV 5HP SIMPLEX IN SERVICE COMP- 10133 CRITICAL COMPRESSOR INGERSOLL RAND B-10 BOILER PLANT POWERHOUSE T30580H IN SERVICE COMP- 10134 CRITICAL COMPRESSOR INGERSOLL RAND B-10 BOILER PLANT POWERHOUSE 71T2-T3011 IN SERVICE COMP- 35B37 CRITICAL COMPRESSOR W/ DRYER COAIRE/QUINC B-35 RESEARCH BASEMENT OSB51-BHL31 IN SERVICE COMPV- 013P14 CRITICAL VACUUM INGERSOLL B-01 MAIN HOSP PENTHOUSE TYPE 30 IN SERVICE COMPV- 018P09 CRITICAL VACUUM BUSCH B-01 MAIN HOSP 8TH FLOOR MM1104BV IN SERVICE COMPV- 018P10 CRITICAL VACUUM BUSCH B-01 MAIN HOSP 8TH FLOOR RC0205 IN SERVICE COMPV- 018P11 CRITCAL VACUUM BUSCH B-01 MAIN HOSP 8TH FLOOR RC0205 IN SERVICE COMPV- 018P12 CRITICAL VACUUM BUSCH B-01 MAIN HOSP 8TH FLOOR RC0205 IN SERVICE COMPV- 018P13 CRITICAL VACUUM BUSCH B-01 MAIN HOSP 8TH FLOOR RC0205 IN SERVICE COMPV- 02B18 CRITICAL VACUUM GARDNER DENVER B-02 DENTAL BASEMENT 2-DV-1610-6.4 IN SERVICE COMPV- 02B19 CRITICAL VACUUM GARDNER DENVER B-02 DENTAL BASEMENT 2-DV-1610-6.4 IN SERVICE COMPV- 35B30 CRITICAL VACUUM SULLAIR B-35 RESEARCH BASEMENT HSP150/01 IN SERVICE The preventive maintenance will include the inspection and service as required by the manufacturer but not limited to the following list of tasks: Check RCVR pressure readings. Check sight glass/ oil level. Check electrical readings. Check Hours. Check for unusual internal and external noises. Check for leaks or unusual odors. Check fasteners and hardware. Inspect pressure relief. Inspect auto drain. Inspect belts, pulleys, and couplings. Inspect air dryers Inspect gauges and regulators. Change/clean separator. Change INT filter. Change lube oil and filter. Parts Contractor shall include a list of all parts covered by Preventive Maintenance with the cost markup. Contractor shall provide the cost mark-up for parts not included in the Preventive Maintenance. Additional Equipment Additional equipment may be added or existing equipment removed from the list when necessary to meet the changing needs of the facility which may be required throughout the life of the contract and shall be considered within scope. Written Reports Written reports for the work completed and recommendations on repairs shall be required with a cost proposal included after each PM and/or service call. Emergency & Repair Service Work The contractor will be required to provide 24/7 response to emergency air compressor and vacuum system problems. Response time will be with-in 2 hours time frame. The contractor will provide a straight time hourly rate and an overtime hourly rate for emergency call- ins and routine repair service. Performance Work Statement Tasks The contractor shall be available to perform the semi-annual preventive maintenance on a schedule that is satisfactory to the hospital. The contractor shall work continuously on preventive maintenance once the work has started until all the units specified in the contract are completed. The contractor shall provide legible and complete reports on all equipment that received preventive maintenance including the repairs required and a cost proposal to perform the repair. The contractor shall respond to all emergency repair call-ins within the 2-hour time frame specified. The contractor shall provide highly qualified technicians with adequate training to resolve all the repair issues encountered. Infection Control The Contractor shall conform to the infection control measures as specified in the attached Construction Specification for Infection Control. Preventive Maintenance Service will normally but not always be performed in a separate work area not subject to all the infection control procedures. Repairs and emergency repairs may be conducted in patient rooms and other hospital areas that are subject to infection control procedures. Work Hours and Project Sequence Routine PM and repair work can start as early as 7:00 am and work past 4:30 pm weekdays. Weekend work needs to be approved by the FMS Supervisor. Emergency service work will occur as conditions dictate. Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement. Responses to this sources sought/RFI are due by 12 pm EST time on September 27, 2021. Responses to this notice shall be submitted via email to jerry.choinski@va.gov. Telephone responses shall not be accepted. If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The NAICS code for this requirement is 811310 and a small size standard of $8,000,000.00
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/5d30c1efca574487961350455ac3c0bd/view)
 
Record
SN06142105-F 20210925/210923230127 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.