SOLICITATION NOTICE
J -- 644-Airflow Testing Isolation Room
- Notice Date
- 9/23/2021 6:46:17 AM
- Notice Type
- Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- 258-NETWORK CNTRCT OFF 22G (36C258) MESA AZ 85212 USA
- ZIP Code
- 85212
- Solicitation Number
- 36C25821Q0397
- Response Due
- 9/24/2021 4:00:00 PM
- Archive Date
- 10/24/2021
- Point of Contact
- JAMES J MORAN, CONTRACT OFFICER
- E-Mail Address
-
James.Moran3@va.gov
(James.Moran3@va.gov)
- Awardee
- null
- Description
- Page 2 of 2 PRESOLICITATION NOTICE: The Department of Veterans Affairs, Network Contract Office (NCO) 22 - Gilbert intends to solicit for a qualified contractor to perform preventive maintenance, and testing and inspection semi-annually and annually that encompasses calculation and analysis of the various rooms listed below at the Phoenix VA Health Care System The Contractor shall furnish all labor, material, equipment, tools and supplies necessary to perform the required services. The rooms include: 29 Isolation Rooms 2 Nuclear Med Isolation rooms 7 Operating Rooms 5 SPS/SPD rooms Tasks for each room include the following: A. Each of the 29 Isolation rooms shall be inspected and tested annually. This testing will consist of: 1. Measure Supply CFM/Exhaust CFM i. Re-Balance space if needed 2. Rebalance Exhaust Fan if needed 3. Rebalance Constant Volume AHU Trunk if needed 4. Rebalance VAV and Calibrate if needed 5. Measure Room Cubic Area i. Calculate Cubic Ft of Room ii. Calculate Air Change Rate 6. Verify Room Pressure Monitor i. Calibrate if needed B. Each of the 2 Nuclear Med Isolation rooms shall be inspected and tested semi-annually. This testing will consist of: 1. Measure Supply CFM/Exhaust CFM i. Re-Balance space if needed 2. Rebalance Exhaust Fan if needed 3. Rebalance Constant Volume AHU Trunk if needed 4. Rebalance VAV and Calibrate if needed 5. Measure Room Cubic Area i. Calculate Cubic Ft of Room ii. Calculate Air Change Rate C. Each of the 7 Operating Rooms shall be inspected and tested annually. This testing will consist of: 1. Measure Supply CFM/Exhaust CFM i. Re-Balance space if needed 2. Rebalance AHU if needed. 3. Recalibrate Phoenix Valves if needed 4. Rebalance Air Outlets if needed 5. Rebalance Cascading Air Pressure if needed 6.Measure Room Cubic Area i. Calculate Cubic Ft of Room ii. Calculate Air Change Rate 7. Verify Room Pressure Monitors i. Calibrate if needed 8. Verify Room Temperature Sensors i. Calibrate if needed 9. Verify Room Humidity Sensors i. Calibrate/replace if needed 10. Verify Supply Air Temperature Sensors D. Each of the 5 SPS/SPD rooms shall be inspected and tested annually. This testing will consist of: 1. Measure Supply CFM/Exhaust CFM i. Re-Balance space if needed 2. Rebalance Exhaust Fan if needed 3. Rebalance AHU if needed 4. Rebalance VAV and Calibrate if needed 5. Rebalance Cascading Air Pressure if needed 6. Measure Room Cubic Area i. Calculate Cubic Ft of Room ii. Calculate Air Change Rate 7. Verify Room Pressure Monitor i. Calibrate if needed E. The Laundry pit room shall be inspected and tested semi-annually. This testing will consist of: 1. Exhaust CFM i. Re-Balance Exhaust Fan if needed 2. Measure Room Cubic Area i. Calculate Cubic Ft of Room ii. Calculate Air Change Rate This requirement is a Firm Fixed Price (FFP) contract. The solicitation number is 36C25821Q0397. The electronic solicitation shall be issued on or about September 13, 2021 and may be downloaded from the following URL https://beta.sam.gov/. This procurement is for total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside. The Department of Veterans Affairs intends to make one award. Point of contact information: James Moran, Contracting Officer, james.moran3@va.gov.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/c5773c4bb8f14936964532909ef52185/view)
- Record
- SN06142336-F 20210925/210923230128 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |