SOLICITATION NOTICE
65 -- Hillrom CENTRELLA SMART+ BED Michael Allred
- Notice Date
- 9/24/2021 12:27:45 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26021Q0982
- Response Due
- 9/27/2021 11:00:00 AM
- Archive Date
- 10/27/2021
- Point of Contact
- Robert Hamilton, Contracting Officer, Phone: 360-852-9880
- E-Mail Address
-
robert.hamilton8@va.gov
(robert.hamilton8@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- 5. PROJECT NUMBER (if applicable) CODE 7. ADMINISTERED BY 2. AMENDMENT/MODIFICATION NUMBER CODE 6. ISSUED BY 8. NAME AND ADDRESS OF CONTRACTOR 4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE 9A. AMENDMENT OF SOLICITATION NUMBER 9B. DATED PAGE OF PAGES 10A. MODIFICATION OF CONTRACT/ORDER NUMBER 10B. DATED BPA NO. 1. CONTRACT ID CODE FACILITY CODE CODE Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers E. IMPORTANT: is extended, (a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended. 12. ACCOUNTING AND APPROPRIATION DATA (REV. 11/2016) is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A. 15C. DATE SIGNED B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b). RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified. C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF: D. OTHER Contractor 16C. DATE SIGNED 14. DESCRIPTION OF AMENDMENT/MODIFICATION 16B. UNITED STATES OF AMERICA Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect. 15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER 15B. CONTRACTOR/OFFEROR STANDARD FORM 30 PREVIOUS EDITION NOT USABLE Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.) (Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.) (If required) (SEE ITEM 11) (SEE ITEM 13) (X) CHECK ONE 13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS, IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14. 11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT (Signature of person authorized to sign) (Signature of Contracting Officer) 1 2 0003 09-24-2021 36C260 Department of Veterans Affairs Network Contracting Office 20 5115 NE 82nd Ave, Suite 102 Vancouver WA 98662 36C260 Department of Veterans Affairs Network Contracting Office 20 5115 NE 82nd Ave, Suite 102 Vancouver WA 98662 To all Offerors/Bidders 36C26021Q0982 09-24-2021 X X X 09-27-2021 14:00 EST See CONTINUATION Page X 1 1. The purpose of this modification is to extend the date and time for responses and update the salient characteristics. 2. The date/time is extended from 09/24/2021 at 15:00 EST to 09/27/2021 at 14:00 EST 3. See continuation page for salient modifications. CONTINUATION PAGE *Changed items The following salient characteristics are modified: - Must have a footboard under bed lighting and alert system Patient status alerts demonstrated on the footboard lighting that has a visual alert for the following: Heart rate and respiratory rate - Early warning to a physical deterioration improves our ability to respond and intervene in a critical condition; Incontinence alert - guidelines from the National Pressure Injury Advisory Panel rated Cleansing the skin promptly after episodes of incontinence as a Strong EBP practice to reduce the potential for skin breakdown due to incontinence. *This system can be visual or aural and does not need to connect to nurse call system. This system is critical for improved patient care. *Watchcare allows for no touch monitoring of incontinence alert that has a visual response to patient becoming wet. This is a safety feature that will reduce the potential pressure injuries. Any equal system or notification must have a similar/equal integrated frame-with-mattress incontinence visual alert. *GCI Touchscreen Left Side or equal system that provides point of care controls. *2nd LCD Touchscreen (nice to have not required) *Each type bed Safe working Load should be a minimum of 500lbs *One button Chair Egress (one button functionality nice to have) Equal item must provide a way to raise for chair egress from the foot of the bed. Post Cardiac ICU team have deemed the full chair position egress is best for open heart patients. *Surface having rotation, percussion and vibration features which aid in decreasing pulmonary complications for ventilated patients - Post Cardiac ICU team have requested this function to reduce patient lung complications. *Xray sleeve is a nice to have feature and not critical. *Head section Inclination: Range from 0 degrees to a minimum of 70 degrees.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/bc59eac8d2d94cb588fb134fac6fd52d/view)
- Place of Performance
- Address: Seattle VA Medical Center 1660 S. Columbian Way, Seattle, WA 98108, USA
- Zip Code: 98108
- Country: USA
- Zip Code: 98108
- Record
- SN06143985-F 20210926/210925200939 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |