SOURCES SOUGHT
65 -- Welch Allyn CIWS 8500 series Vital Sign Monitors
- Notice Date
- 9/29/2021 10:56:28 AM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26022Q0022
- Response Due
- 10/4/2021 1:00:00 PM
- Archive Date
- 11/03/2021
- Point of Contact
- Ladell D Holmes, Ladell Holmes, Phone: (360) 816-2763
- E-Mail Address
-
Ladell.Holmes@va.gov
(Ladell.Holmes@va.gov)
- Awardee
- null
- Description
- The Anchorage VAMC is seeking Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), or Small Business sources capable of meeting the requirement listed below. The acquisition will be accomplished using commercial item procedures in accordance with FAR Part 12. Minimum Salient Characteristics: Welch Allyn CIWS 8500 series Vital Sign Monitors GENERAL FEATURES 15-second NIBP and pulse rate Adult, pediatric and neonatal NIBP modes Spot check, monitoring and triage modes included Masimo® or Nellcor® pulse oximetry Programmable visual and audible alarms for BP, SpO2, temp and pulse service software-ready for software-driven repairs and upgrades 4 USB accessory ports Manual measurements entry (weight, height, respiration rate, pain) and documentation of modifiers, like body position and O2 therapy Large color touchscreen display simplifies training and operation Descriptive error messages for easy troubleshooting Fully customizable USB configuration cloning Integrated 3.5 V handles for physical assessment instruments integrated ear speculum dispenser Wireless connectivity Power cord length 8 Display area 8 in. (H) x 4 in. (V) (20.3 cm [H] x 10.2 cm [V]) Speaker Volume - 57 dB at 1.0 meter Battery Composition Lithium-ion Nurse Call Connection NIBP SPECIFICATIONS Systolic range: Adult: 30 to 260 mmHg; Pediatric: 30 to 260 mmHg; Neonate: 20 to 120 mmHg Diastolic range: Adult: 20 to 220 mmHg; Pediatric: 20 to 220 mmHg; Neonate: 10 to 110 mmHg Blood pressure determination time Typical: 15 seconds; Maximum: 150 seconds Blood pressure tubing length 8 Blood pressure accuracy: Meets or exceeds ANSI.AAMI SP10:2002 standards for noninvasive blood pressure; Meets or exceeds ANSI.AAMI SP10:2002 standards for noninvasive accuracy (± 5 mmHg mean error, 8 mmHg standard deviation) TEMPERATURE SPECIFICATIONS Oral temperature range: 80 °F to 110 °F (26.7 °C to 43.3 °C) Ear temperature range: 68 °F to 108 °F (20.0 °C to 42.2 °C) SpO2 SPECIFICATIONS SpO2 performance measurement range 1 to 100% SpO2 cable length 10 ENVIRONMENTAL SPECIFICAITONS Operating temperature 50 °F to 104 °F (10 °C to 40 °C); Storage temperature -4 °F to 122 °F (-20 °C to 50 °C) Operating altitude -557 to 10,000 ft. (-170 m to 3,048 m) Operating humidity 15 to 95% noncondensing; Storage humidity 15% to 95% noncondensing Handle output 3.00-3.90 V, .70-1.50 A; 767 power handle cord lengths 12 Electrical Rating: 100-240 V AC, 50-60 Hz, 1.50-.08 A GENERAL COMPLIANCE AND STANDARDS: ANSI/AAMI SP10 | AS/NZS 3200.1.01 | ASTM D 4332, E 1104 | CAN/CSA C22.2 NO.601.11 CAN/CSA-C22.2 NO.60601-1-2, CSA Z9919 EN 1060-1, 1060-3, 1060-42 | EN/IEC 60601-1, 60601-1-2, 60601-1-4, 60601-1-6, 60601-1-8, 60601-2-30, 60601-2-49, 62304 EN/ISO 9919, 13485, 14971 | ISTA 2A | UL 60601-11 The North American Industry Classification System (NAICS) is 339112. Any SDVOSB, VOSB, or Small Business firms who wish to identify their interests and capability to provide this product must provide product specifications, performance, and delivery information by notifying the Contract Specialist no later than 1:00 PM Pacific Standard Time, October 4, 2021. Notification shall be e-mailed to Ladell Holmes, at ladell.holmes@va.gov. Any vendor who responds to this Notice must provide credentials to perform the requirement as outlined in the below scope.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/04f8af5af9b74bada8820394fc913699/view)
- Place of Performance
- Address: Department of Veterans Affairs Anchorage VAMC 1201 N. Mulddon RD, Anchorage, AK 99504, USA
- Zip Code: 99504
- Country: USA
- Zip Code: 99504
- Record
- SN06148087-F 20211001/210930203830 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |