SOURCES SOUGHT
65 -- 200 kVA UPS System for 3T MRI Scanner
- Notice Date
- 11/5/2021 6:30:02 AM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- NATIONAL INSTITUTES OF HEALTH NIDA Bethesda MD 20892 USA
- ZIP Code
- 20892
- Solicitation Number
- 75N95022Q00016
- Response Due
- 11/22/2021 11:00:00 AM
- Archive Date
- 12/07/2021
- Point of Contact
- Diedra Prophet, Karen Mahon
- E-Mail Address
-
diedra.prophet@nih.gov, karen.mahon@nih.gov
(diedra.prophet@nih.gov, karen.mahon@nih.gov)
- Description
- Description: This is a Small Business Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are small businesses; HUBZone small businesses; service-disabled, veteran-owned small businesses; 8(a) small businesses; veteran-owned small businesses; woman-owned small businesses; or small disadvantaged businesses; and (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice. This notice is issued to help determine the availability of qualified companies technically capable of meeting the Government requirement and to determine the method of acquisition. It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The Government will NOT be responsible for any costs incurred by the respondents to this notice. This notice is strictly for research and information purposes only. Background: The Philips 3T Ingenia MRI scanner at Medstar Harbor Hospital is the core instrument for clinical imaging studies in the NIA Intramural Research Program. The MRI scanner requires a very stable, reliable electrical power source in order to generate images without artifacts and to prevent damage to sensitive electronic components. Purpose and Objectives: This request requires a Staco 200kVA UPS System plus two extended runtime battery cabinets, maintenance bypass switch and SNMP network interface new uninterruptable power supply (UPS) to support the Philips 3T MRI scanner in the NIA-IRP Clinical Research Center, located at Medstar Harbor Hospital in Baltimore, MD. Project Requirements: Salient characteristics of the requested services include: Compatible with existing Philips 3T Ingenia MRI scanner 480 volt three-phase delta input power (for compatibility with Hospital power mains) 480 volt three-phase wye output power (for compatibility with Philips MDU/DACC cabinet) Minimum 200 kVA capacity (for support of MRI console and KKT cBoxX 100 chiller) Minimum run time of 60 minutes at 80% load (to maintain operation of magnet cold head refrigeration system) 300 A maximum input current (for compatibility with existing circuit breaker and wiring) Dry contacts for general alarm (to connect to Hospital�s JCI building management system) Remote panel to monitor UPS from MRI control room Emergency power off (EPO) switch for installation in equipment room 34� maximum depth for all cabinets (to fit available space in 3T MRI equipment room)\ 108� maximum total width of UPS cabinet plus battery cabinets (to fit available space) 80� maximum cabinet height (to fit underneath existing overhead HVAC ducts) Wall-mounted maintenance bypass switch (to perform service without cutting power to critical loads) SNMP network interface (needed for monitoring system from outside 3T MRI Facility) Rigging out and disposal of existing Toshiba G8000 UPS and associated battery cabinets, bypass switch and remote monitoring panel Rigging in of new UPS and associated battery cabinets, bypass switch and accessories Startup service included for new UPS. Anticipated Delivery Date: Six � Eight Weeks (ARO) Capability statement /information sought. The intent of this sources sought notice is to define the procurement strategy (e.g., set-aside, sole source, unrestricted) for a solicitation that is intended to be posted soon. Interested vendors are requested to respond by (1) identifying how their proposed product meets or exceeds the project requirements listed above; and (2) providing product literature, white papers, or capability statements that demonstrate their bona fide ability to supply such an item within the time frame described above. In addition, please state your business size status and whether you are the manufacturer or authorized distributor of the item you propose. Please note that the NIA is particularly interested in small business sources. If you are a small business, please state the type of small business (small business; HUBZone; service-disabled, veteran-owned; 8(a); veteran-owned; woman-owned; or small disadvantaged businesses) and your size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. The respondent must also provide their DUNS number, organization name, address, point of contact, and size and type of business (e.g., 8(a), HubZone, etc., pursuant to the applicable NAICS code and any other information that may be helpful in developing or finalizing the acquisition requirements. One (1) copy of the response is required and must be in Microsoft Word or Adobe PDF format using 11-point or 12-point font, 8-1/2� x 11� paper size, with 1� top, bottom, left and right margins, and with single or double spacing. � The information submitted must be in an outline format that addresses each of the elements of the project requirement and in the capability statement /information sought paragraphs stated herein. A cover page and an executive summary may be included but is not required. � The response is limited to ten (10) page limit. The 10-page limit does not include the cover page, executive summary, or references, if requested. � The response must include the respondents� technical and administrative points of contact, including names, titles, addresses, telephone and fax numbers, and e-mail addresses. All responses to this notice must be submitted electronically to the Contract Specialist. � Facsimile responses are NOT accepted.� The response must be submitted to Diedra Prophet at e-mail address diedra.Prophet@nih.gov The response must be received on or before Monday, November 22, 2021, at 2:00pm, Eastern Time. � Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization�s qualifications to perform the work. � Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a presolicitation synopsis and solicitation may be published in www.sam.gov. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/37a914d046f7486fab4cb96b87ccd9ef/view)
- Place of Performance
- Address: Baltimore, MD 21224, USA
- Zip Code: 21224
- Country: USA
- Zip Code: 21224
- Record
- SN06172177-F 20211107/211105230118 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |