SOURCES SOUGHT
J -- FY22: VISN8 Patient Lift Preventative Maintenance Base Year
- Notice Date
- 11/22/2021 12:22:48 PM
- Notice Type
- Sources Sought
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- 248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
- ZIP Code
- 33637
- Solicitation Number
- 36C24822Q0187
- Response Due
- 11/30/2021 2:30:00 PM
- Archive Date
- 12/30/2021
- Point of Contact
- Keila President, Contract Specialist, Phone: 813-972-2000 Ext 5998
- E-Mail Address
-
keila.president@va.gov
(keila.president@va.gov)
- Awardee
- null
- Description
- Page 6 of 6 Sources Sought/Request for Information (RFI) is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future. The Department of Veterans Affairs (VA), James A. Haley Veterans Administration Medical Center (JAHVAMC), 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, is currently seeking information from vendors with the capability to provide preventative maintenance, repair, inspection and installation services on ceiling mounted patient lift, lift gates, rails, and turnstiles. A certified technician must be able to perform maintenance and repair on all equipment regardless of the manufacturer. The applicable NAICS for this service is: 811219, Other Electronic and Precision Equipment Repair and Maintenance, Size Standard: $22,000,000.00. Vendors must be registered in the System for Award Management SAM.gov | Home prior to award. Equipment: Estimated quantities of installed and inventory stock is approximately 1,470 patient lifts, lift gates, rails, and turnstiles systems and the manufacturers are: ARJO, LIKO, Guldman, Getinge and Tollos. Below are locations requiring services. located at the below listed facilities. James A Haley Veterans Hospital and associated Clinics, 13000 Bruce B. Downs Blvd. Tampa, FL 33612. Lakeland Community Based Outpatient Clinic, 4237 South Pipkin Rd Lakeland, FL 33811. New Port Richey Outpatient Clinic, 9912 Little Road, New Port Richey, FL 34654. James A. Haley Veterans' Hospital Primary Care Annex, 13515 Lake Terrace Lane Tampa, FL 33637. Zephyrhills Community Based Outpatient Clinic, 6937 Medical View Lane, Zephyrhills, FL 33542. Orlando VA Medical Center and Clinics, Orlando, Florida VA Caribbean Healthcare System and Clinics, San Juan, Puerto Rico The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved service personnel for each model the Contractor services at the JAHVAMC to the Contracting Officer s Representative (COR). Contractor shall revise this documentation whenever service personnel are assigned or re-assigned to the JAHVAMC. The COR reserves the right to request authentication of factory training certificates or credentials from the Contractor at any time for any personnel who are servicing JAHVAMC equipment. The contractor will not require access to VA sensitive information, therefore the Certification and Accreditation (C&A) requirement in accordance with (IAW) VA Handbook 6500.6 Contract Security does not apply. II. SCOPE Contractor must furnish all necessary labor, supervision, equipment, tools, materials, repair service, software updates, parts, weight testing, etc., preventative maintenance, repair, inspection, and installation service of ceiling mounted patient lift, lift gates, rails, and turnstiles systems as specified with manufacturers recommendations, terms, conditions and schedule of this Performance Work Statement (PWS). Contractor shall be required to sign in with the COR after contract award, before beginning a service call and when the COR is not available and during Weekends, Holidays, Evenings and Nights Hours (WHEN), the Contractor shall sign in/out at the Central Energy Plant Building# 39. Upon completion of Preventive Maintenance (PM) inspection the Contractor shall leave a copy of the service report with the using service, and submit to the same location as designated above a service report annotating what service, calibration, etc., were performed and whether preventive maintenance was done. Each service report shall include the name of the contractor, name of Field Service Engineer (FSE), date, time (starting and ending), equipment downtime, hours of labor including costs (when emergency service is authorized outside of normal working hours), the parts utilized including costs, the nature of the problem, the nomenclature of the item replaced (serial number & VA inventory number), and the room number where equipment is located. The service designee and the FSE attesting that the equipment is in satisfactory working order and is functioning at an acceptable level of performance shall sign this report. The contractor shall sign out at the designated location before leaving. NOTE: Failure to furnish a service report or obtain a signed copy of the service report could result in delay of payment or non-payment. The COR or alternate COR has the authority to approve/request a service call from the contractor. Preventive maintenance (PM): Certification and semi-annual inspections/Preventative Maintenance (PM) are scheduled through the COR. The contractor shall perform PM service to ensure that equipment listed in schedule functions in conformance with the latest published editions of NFPA, OSHA, CDRH. The contractor shall provide and utilize procedures and checklists with worksheet originals indicating work performed and actual values obtained (as applicable) provided to the COR at the completion of the PM. PM procedures will be submitted to the COR for approval prior to the initiation of this service contract. PM Services shall include but not be limited to the following: Cleaning of equipment Reviewing operating system software diagnostics to ensure that system is operating to the manufacturer s specifications. Calibrating and lubricating the equipment. Performing remedial maintenance of non-emergent nature. Test and replacing faulty and worn parts and/or parts which are likely to become faulty fail or become worn. Adjusting and calibrating as necessary. Inspecting electrical wiring and cables for wear and fraying. Inspecting all mechanical components including, but not limited to patient restraints and support devices, chains, belts, bearing and tracks, interlocks, clutches, motors, mechanical integrity, safety, and performance being priority Performing Electrical Safety Inspections, which should include line cord ground wire resistance and leakage as specified in the Conformance Standards. PERIOD OF PERFORMANCE: The contract will be performed for five years (one base year and four-one-year options). REPONSES Responses to this Sources Sought/Request for Information Notice shall be able to demonstrate the company s capability to responsibly deliver the services listed in the Performance Work Statement (PWS). The purpose of this Special Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified vendors interested and capable of providing the services described in the PWS. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. No funds have been authorized, appropriated, or received for this effort. If your firm is fully qualified to perform the required services, please provide the below requested information regarding your firm: A. The applicable NAICS Code for this service is: 811219, Other Electronic and Precision Equipment Repair and Maintenance, Size Standard: $22,000,000.00. If your company meets the requirements and is capable of providing these services, please ensure this NAICS code is currently listed under your company in SAM, or have it added right away. Please check any and all of the following that apply: Service disabled; veteran owned small business_________ Veteran owned small business _______ Small business_______ (8a) firm _________ HUB zone ________ Large Business/Other than small business firm__________ GSA Schedule (if applicable) _______________ B. Responses to this notice shall also include the following information: Company Name: DUNS #: Full Address: Point of Contact Information (Job title, Phone Number and E-mail Address): C. Any pertinent information which demonstrates your firm s ability to meet the above requirements. Any response that does not provide the necessary information in the capability statement will be a negative capability response. All offerors must be registered in the System for Award Management (SAM.gov | Home) and Representations and Certifications must be completed prior to any future award. To be considered as a Service Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) interested vendors must be a verified SDVOSB/VOSB concern in the VA Center for Verification and Evaluation (CVE) Veteran Information Pages (VIP) pages https://www.vip.vetbiz.gov/. IMPORTANT INFORMATION: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Sources Sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Any offeror capable of providing this service shall notify the Contracting Officer by email within seven (7) calendar days from the date of the publication of this special notice. *Responses and questions shall be sent via email to keila.president@va.gov, no later than 5:30 PM EST on 11/30/2021. Please title the email, Patient Lifts .
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/c616ce5d61be4ec1887a10811a1039ff/view)
- Record
- SN06183566-F 20211124/211122230121 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |