Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 24, 2021 SAM #7298
SOURCES SOUGHT

65 -- Emergency Ablation Machine

Notice Date
11/22/2021 10:29:10 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
256-NETWORK CONTRACT OFFICE 16 (36C256) RIDGELAND MS 39157 USA
 
ZIP Code
39157
 
Solicitation Number
36C25622Q0191
 
Response Due
11/25/2021 5:00:00 AM
 
Archive Date
12/05/2021
 
Point of Contact
William Shaver, Contract Specialist, Phone: 601-206-6953
 
E-Mail Address
William.Shaver@va.gov
(William.Shaver@va.gov)
 
Awardee
null
 
Description
DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 REQUEST FOR INFORMATION 36C25622Q0191 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name products listed in the Statement of Work and Schedule found in the background section below. In the response, please cite business size status. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and DUNS Number. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing these types of supplies. Please include the following: (a) Proof of OEM or OEM distributor of brand name supplies. (b) examples of prior completed Government contracts, references, and other related information. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to William.Shaver@va.gov. Please respond to this RFI no later than 07:00 Central Standard Time on Thursday, November 25, 2021. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. BACKGROUND: Statement of Work Brand Name Item: Essential/significant physical, functional, or performance characteristics. NovaSure is an impedance controlled endometrial ablation system. The NovaSure RF Controller is a constant power output generator with a nominal maximum power delivery capability of 180 watts. The controller automatically calculates the power output based on the uterine cavity length and width measurements that the user key enters into the controller. Monitoring tissue impedance during the ablation process automatically controls the depth of endo-myometrial ablation. The NovaSure procedure self-terminates once endometrial vaporization and superficial myometrial desiccation have reached 50 ohms of impedance at the tissue-electrode interface, or when the timer reaches 2 minutes. Integral to the controller is the cavity integrity assessment system which is designed to determine whether there is a defect or perforation in the wall of the uterus. A vacuum pump contained within the NovaSure RF controller creates and maintains a vacuum in the uterine cavity throughout the endometrial ablation procedure. Minimum requirements: Compatibility NovaSure RF controller, NovaSure CO2 Canister, NovaSure Desiccant, NovaSure foot switch and Power cord Purpose Safety and effectiveness of the use of the NovaSure system was compared to wire loop resection of the endometrium followed by roller ball ablation in premenopausal women suffering from menorrhagia secondary to benign causes. Governing Body or Organization Complete generic identification NovaSure Applicable model/make/catalog number - RFC2010-115, 814002, RFC2000-FS, 81501US Manufacturer name Hologic Per VAAR 811.104 and 811.105, I certify the following regarding the above information: The salient characteristics listed above are essential to the Government s requirements. To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacturer. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/60f313c2731c4ac4bb216f8244273ee7/view)
 
Place of Performance
Address: Department of Veterans Affairs Central Arkansas Veterans Healthcare System BLDG 182 2200 Fort Roots Drive, Little Rock 72114, USA
Zip Code: 72114
Country: USA
 
Record
SN06183635-F 20211124/211122230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.