Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 05, 2022 SAM #7340
SOLICITATION NOTICE

65 -- Restricted Barrier Access System

Notice Date
1/3/2022 7:48:31 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25022Q0203
 
Response Due
1/11/2022 9:00:00 AM
 
Archive Date
02/10/2022
 
Point of Contact
Aleshia.Hines-Best@va.gov, Aleshia Hines-Best, Phone: 937-262-2185
 
E-Mail Address
Aleshia.Hines-Best@va.gov
(Aleshia.Hines-Best@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation RFQ-36C250-22-Q-0203 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-94, 2005-95/ 01-19-2017. The North American Industry Classification System (NAICS) number is 339113 and the business size standard is 1,000 employees. STATEMENT OF NEED Nuaire PharmaGard NU-PR797 Compounding Aseptic Isolator (CAI) Restricted Access Barrier System Quantity (1) C.0. SCOPE: The Roudebush VA Medical Center, Indianapolis, IN has a requirement for a brand name or equal to: - Nuaire PharmaGard NU-PR797 Compounding Aseptic Isolator (CAI) Restricted Access Barrier System Quantity (1) PLEASE SEE BELOW FOR SALIENT CHARACTERISTICS a. Provide required items within 180 days of award. The proposed contract listed here is Set-aside 100% for Service-Disabled Veteran Owned Small Business. FOB destination. Deliver to 1481 W 10th Street., Indianapolis, IN 46202. Offerors must comply with all instructions contained in provision 52.212-1, Instructions to Offerors-Commercial, applies to this acquisition. 52.203-98, 52.204-22 52.211-6, Brand Name or Equal (AUG 1999) 52.212-2, Evaluation - Commercial Items: FAR provision 52.212-2 does not apply to this solicitation. Award will be based on lowest price technically acceptable offer. 52.212-3, Offeror Representations and Certifications-Commercial Items, a completed copy of this provision shall be submitted with the offer unless SAM registered which must be noted in the quotation. 52.212-4, Contract Terms and Conditions-Commercial Items. The following additional clauses apply: 52,203-99, 52.232-40, 852.203-70, 852.232-72 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, to include clauses: 52.219-6, 52.219-28, 52.222-3, 52.222-19, 52.222-21; 52.222-50, 52.223-18, 52.225-1; 52.225-13, 52.232-34 RESPONSES ARE DUE Tuesday January 11, 2022 by 12:00 P.M. eastern standard time (EST). Electronic offers will be accepted Aleshia Hines-Best, e-mail Aleshia.Hines-Best@va.gov. Point of contact for this solicitation is Aleshia Hines-Best, e-mail Aleshia.Hines-Best@va.gov. All Inquires must be in writing. Statement of Work The Indianapolis VAMC Pharmacy Service has a requirement for one (1) Nuaire PharmaGard NU-PR797 Compounding Aseptic Isolator (CAI) Restricted Access Barrier System with the following salient characteristics: Stainless steel interior surfaces Intended for pharmacy compounding ISO Class 5 or better environment 20 air changes per hour in work chamber IV bar o Prefer options for multiple positions Maximum Exterior Dimensions o Height: 78.5 inches (including base stand with wheels) o Width: 33 inches o Length: 60 inches Minimum Work Chamber Dimension o Width: 32 inches o Depth: 22 inches Waste disposal system with access from work chamber for sharps and/or waste Sliding transfer door between chambers Runs on 110-120 volt power; should not require hard wire connection Base stand must be adjustable and on wheels o Prefer complete unit with hood and attached stand Prefilter located on top of the unit Visual gauges for pressures of each chamber o Prefer Digital monitor alert for pressures monitoring Cord Pass through 2 glove ports o Option for larger than 4inch diameter O-ring to attach gloves Left side interchange
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/6297da9aa9a74902a6e5421beb211662/view)
 
Place of Performance
Address: Roudebush VA Medical Center 1481 W 10th Street, Indianapolis 46202
Zip Code: 46202
 
Record
SN06208141-F 20220105/220104201325 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.