SOURCES SOUGHT
65 -- FRI _ PHENO ACCESORIES 659-22-1-048-0047
- Notice Date
- 1/3/2022 8:48:46 AM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24622Q0161
- Response Due
- 12/17/2021 1:00:00 PM
- Archive Date
- 03/26/2022
- Point of Contact
- MAURICE ANDERSON, CONTRACT SPECIALIST, Phone: (910) 488-2120 x7718
- E-Mail Address
-
MAURICE.ANDERSON1@VA.GOV
(MAURICE.ANDERSON1@VA.GOV)
- Awardee
- null
- Description
- This is a sources sought notice only. This notice does not constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. Market Research is being conducted to Service Disabled Veteran owned small business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business, Small Disadvantaged Business, 8(a), Woman Owned Small Business or Hub zone interests. The Salisbury North Carolina Veterans Affairs Medical Center (VAMC) is trying to determine whether to set aside the acquisition for item(s) ************************************************************************************* BINSART700P 1 Arterion Pedestal Install 1 EA 14432925 2 PERISTEPPING / PERIVISION Motorized stepping for real-time bolus chasing. C-arm stepping with ARTIS pheno and ceiling mounted systems, table stepping with floor mounted and biplane systems. 1 EA 14432994 3 DICOM Attribute Converter Individual solution via software-/XML-files, to solve compatibility problems. 1 EA 14440459 4 Arm rest Arm support used for the arm approach. Length: 1 m (39.4''). Slides underneath the patient mattress and is held in position by the patient's weight. Made of radiolucent carbon fiber material which is easy to clean. It includes two additional support pads of two different heights (4 and 7 cm). Length pad: 60 cm / 23.62'' Width: 9 to 20 cm / 3.54'' to 7.87'' Maximum weight: 5 kg (11.02 Ib) Weight (with pads): 2.1 kg / 4.63 lb E 1 EA 14440460 5 Arm holder (pair) The patient's arms can be comfortably placed along the body using these two arm holders. They slide underneath the patient mattress and is held in position by the patient's weight. It includes two pairs of arm holders of different length (540 mm / 690 mm - 21.2'' / 27.2'') and height (85 mm / 115 mm - 3.35'' / 4.53''), suitable both for thick and thin patient mattresses. 1 EA 14440451 6 Instrument tray This item can be positioned at the accessory rails of the patient table sideways above the patient. It can be swiveled and is height-adjustable. 1 EA BART700PEDL 7 Mark 7 Arterion, Pedestal System The Arterion Mark 7 Pedestal contrast medium injector can be positioned anywhere at the patient positioning table on a mobile unit, for direct operation of all functions in the examination room. The injector system includes: A mobile pedestal stand with electronics unit, a contrast medium heater and a connection cable to the manual release. A support arm with injector head and a control lever for moving the injector head. A user control console with large touch screen and corresponding additional monitoring display on the injector head. Functions Pressure limitation: for 150 ml syringes 689 to 8273 kPa, corresponds to 100 to 1200 psi. Flow rates for 150 ml syringes: 0.1 to 45 ml/s in increments of 0.1 ml/s 0.1 to 59.9 ml/min in increments of 0.1 ml/min rise/fall: 0 to 9.9 s in increments of 0.1 seconds Release delay for injection or radiation: 0 to 99.9 s in increments of 0.1 s. Adjustable volume for 150 ml syringes: 1 ml to the max. syringe capacity in increments of 1 ml. Fill rate: Variable syringe filling speed 1-20ml/s. Injection protocols: Up to 40 injection protocols possible. Parameters currently displayed on the touch screen display and on the head display: Injection speed Injection volume Remaining volume Injection duration Applied pressure Contrast medium heating: Nominal 35°C (95°F)+-5°C (9°F) Injection data memory Up to 50 injection data items stored Included in the scope of delivery Injector standard configuration 150 ml SIEMENS interface cable Operator Manual Service manual (English). Power supply 200 V to 250 V; 50/60 Hz. 1 EA 14432926 8 Card acq. mode w/high speed Card Highspeed enables image acquisition with up to 30 frames per second and helps visualizing a moving heart. 1 EA ************************************************************************************* This Sources Sought notice is to determine interest and capability of small businesses, service-disabled veteran owned small business, and veteran -owned small business firms relative to NAICS 339112 and the Department of Veterans Affairs is seeking small business manufactures or distributors of small business manufactures or functionally equivalent to the above listed . If your company is interested in performing these services, please notify our office of your intent. Please email capability statements. This is an emergency requirement so a quick response will be needed. Reply by 4:00pm on January 7, 2022.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/a3fe45d6fe7d48f7b52c3fe9b092f7a3/view)
- Place of Performance
- Address: VAMC SALISBURY 1601 BRENNER AVENUE, Salisbury, NC 28144, USA
- Zip Code: 28144
- Country: USA
- Zip Code: 28144
- Record
- SN06208253-F 20220105/220104201325 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |