Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 14, 2022 SAM #7349
MODIFICATION

J -- N69450-22-F-9950 J&A for EMCS Server Improvements and Upgrades, Naval Air Station, Fort Worth, Texas

Notice Date
1/12/2022 10:51:59 AM
 
Notice Type
Justification
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
NAVFAC SOUTHEAST JACKSONVILLE FL 32212-0030 USA
 
ZIP Code
32212-0030
 
Solicitation Number
N69450-22-F9950
 
Archive Date
02/11/2022
 
Point of Contact
Eric Smith, Phone: 8177825274, Jeannette Sale, Phone: 8177827985
 
E-Mail Address
eric.c.smith6.civ@us.navy.mil, jeannette.c.sale.civ@us.navy.mil
(eric.c.smith6.civ@us.navy.mil, jeannette.c.sale.civ@us.navy.mil)
 
Award Number
GS06F0060P
 
Award Date
03/14/2022
 
Description
Contractor shall furnish all equipment, materials, parts, supplies and tools necessary for the performance of the work to upgrade the JCI server located at building 1215. NAS JRB Fort Worth is dealing with an aging Metasys based system and the aging system is potential in security risk due to less technical support being available for the Windows based machine onsite. To mitigate this issue, NAS JRB Fort Worth will have to upgrade and improve to Metasys system that is supported by both Microsoft and JCI for the latest security patches. ADX is a larger scale system that runs on a server operating system to provide extended historical archiving and reporting capabilities. NAS JRB proposes to fix this issue by installing a new ADX server software and replacing NAEs to take control of the existing field controllers. 1. Install new Johnson Controls Metasys 12.0 System with one (1) Extended Application Data Server (ADX) for 10 users with twenty (20) SNE22001 and twenty four (24) SNE105001/SNC2515 Network Application Engines to be installed. 2. Contractor shall perform field survey to verify for the existing condition and inventories before replacement or bid. Inventories of existing NAE or NCE can be obtained from the server or EMCS located at building 1215. 3. Furnish and install new SQL software, virtual server needed to install and configure server in conjunction with the JCI. 4. Contractor shall provide the server and SQL software per manufacture�s specification. 5. Prior to new server installation, backup existing system and convert to the newest platform. 6. Verify the function and configuration of the software and server. 7. Replace all NAE controllers and upgrade the software of existing controllers at each one of the buildings listed below which each building will have unique points. 8. Remove the existing twenty (20) NAE-1 and install twenty (20) new SNE22001 in their place. 9. Remove the existing twenty-four (24) NCEs and install Twenty-four (24) new SNE10501/SNCs and install new panels in their place. 10. All outdated NAE and NCE that are not compatible to newest platform will be replaced. Quantities are as indicated in statement #9. 11. All existing wires shall be terminated to new locations on the new controller. 12. Confirm programming and operation of the new controller onsite. 13. Ensure all controller is communicating with the new server and that data and graphics are correct. Each building will have unique points that can be pulled in. 14. Provide required training for the functionality and maintenance to HVAC control shop technicians. 15. All completed server upgrade shall be tested and provide all required training to PWD personnel. 16. Server package on a site must be licensed after a new installation. 17. All the backup system/files shall be installed back for normal operation. 18. Provide the field devices and wiring including DDC controllers, relays, sensors, transducers, control devices, control panels, controller programming, controller programming software, controller input/output and power wiring and controller network wiring to provide a complete working system of the mechanical equipment. 19. Replace only deteriorated panels with new NEMA-1 or 2 to minimize the downtime of HVAC systems. 20. The followings are the NAE number for each building number: 1016, 1048, 1050, 1068, 1215, 1324, 136, 1403, 1520, 1521, 1522, 1523, 1524, 1567, 1568, 1752, 1802, 1803, 1810, 1815, 1845, 1445, 4210, 4215, 1055, 1411, 1513, 1525, 1720, 3320, 4205. 21. The followings are the NCE number for each building number: 1410, 3319, 152-2, 1425, 1501, 1060, 1550, 2570, 1049, 1055-2, 1303, 1330, 1360, 1515, 1730, 1838, 1838-2, 3355, 1409, 1422.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/e3f2f854a74c4eec9ef939095bfb331c/view)
 
Place of Performance
Address: Naval Air Station JRB, TX 76127, USA
Zip Code: 76127
Country: USA
 
Record
SN06215451-F 20220114/220112230103 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.