MODIFICATION

J -- 137th Backflow Repair

Notice Date
1/19/2022 10:09:42 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
W7NV USPFO ACTIVITY OKANG 137 OKLAHOMA CITY OK 73179-1051 USA
 
ZIP Code
73179-1051
 
Solicitation Number
W50S8T-22-Q-A001
 
Response Due
2/1/2022 8:00:00 AM
 
Archive Date
02/16/2022
 
Point of Contact
Capt Ryan Moehle, Phone: 4056865442, SMSgt Christine Walker, Phone: 4056865348
 
E-Mail Address
ryan.moehle@us.af.mil, christine.walker@us.af.mil
(ryan.moehle@us.af.mil, christine.walker@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and any additional written solicitation will not be issued. The 137th SOW LRS at Will Rogers Air National Guard (WRANGB) is preparing to award a Firm Fixed Price Contract to a vendor to repair Backflow deficiencies in buildings located across the base. The desired delivery is 60 days ADC (After Date of Contract). Provide Backflow Repair IAW commercial standards and the Performance Work Statement. Employ services of a Qualified Fire Protection Engineer (QFPE) to design and specify a replacement backflow prevention assembly for the fire sprinkler riser in Building 1045 per UFC 3-600-01, AWWA Manual M 14, UFGS 21 13 13 Wet Pipe Sprinkler Systems, Fire Protection, ASSE 1013, and ASSE 1015. Provide all materials, pipe, fittings, repair kits, backflow devices, valves, supervisory switched and connections to facility FACP, and labor to repair deficiencies or replace backflow device as listed in the inspection reports. All installation and repair work to be performed by a licensed plumber journeyman with the Oklahoma Construction Industries Board or an ASSE 5130 Certified Backflow Prevention Assembly Repairer, whichever is applicable. All work to be performed in compliance with American Society of Sanitary Engineering (ASSE) and IPC 2015. Once repaired or replaced, backflow devices are to be tested for proper operation in accordance with ASSE 1013 and/or ASSE 1015 by an ASSE 5110 Backflow Certified Tester. Corrective actions for each backflow device are to be documented on the updated inspection reports. All repairs shall meet commercially accepted standards and functionality and restore Backflow Prevention Assemblies to fully operational states. Please see attached Combined Synopsis/Solicitation, PWS, and Wage Determination for further details.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/b213c0952f3943ada9f5a5997e9ef110/view)
 
Place of Performance
Address: Oklahoma City, OK 73179, USA
Zip Code: 73179
Country: USA
 
Record
SN06219812-F 20220121/220119230104 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.