Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 26, 2022 SAM #7361
SOLICITATION NOTICE

Y -- CON 668-22-102 Install Eye Wash for Housekeeping Sinks Campus Wide

Notice Date
1/24/2022 3:11:39 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
 
ZIP Code
98662
 
Solicitation Number
36C26022Q0129
 
Response Due
2/10/2022 6:00:00 PM
 
Archive Date
05/11/2022
 
Point of Contact
Paul.Richardson2@va.gov, Paul Richardson, Phone: 208-429-2010
 
E-Mail Address
paul.richardson2@va.gov
(paul.richardson2@va.gov)
 
Small Business Set-Aside
SDVOSBS Service-Disabled Veteran-Owned Small Business (SDVOSB) Sole Source (FAR 19.14)
 
Awardee
null
 
Description
Spokane VAMC is soliciting for a SDVOSB to completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor and materials and perform work for 668-22-102 Install Eye Washes in Housekeeping Closet Campus Wide as required by drawings and specific. Questions and Answers 1 - Has a Hazardous Materials Survey been conducted and available for all aspects of this construction project? Federal Regulation (40 CFR Section 61.145) requires that building owners conduct, or have conducted a Survey for Asbestos Containing Materials (ACM), or Presumed Asbestos Containing Materials (PACM) and other hazardous materials (such as lead, PCB s, mold, etc.) prior to the start of any demolition or renovation activities. The Survey must be conducted by an AHERA/EPA Certified Building Inspector. Copies of any materials testing data, and the complete report must be maintained by the Owner, and provided to any and all contractors who propose to work for the specific renovation activities. No, a Hazardous Materials Survey will have to be conducted by the contractor. 2 - Section 01 00 00 1.29 Construction Sign & 1.30 Safety Sign Will signs or signage be required for this project? Yes, a construction sign is required, can be a piece of paper taped to the door with all the pertinent project information. A safety sign is not required. 3 - Section 01 35 26 1.9 - Inspections SSHO / CSP / CSHT. Will a CSP or CSHT inspection as identified in 01 35 26 1.9B be required on this limited project. No, a SSHO is sufficient. 4 - Section 01 35 26 1.13 Tuberculosis Screening Will Tuberculosis screening be required at this VA facility? Contractor personnel must meet appropriate health screening requirements for the VA facility. 5 - Section 01 45 00 3.4 Quality Control Organization calls for a QC team with extensive qualifications. Due to the limited size and nature of this project, will this in-depth QC Organization be required? No 6 Can the project Superintendent also act as the SSHO and QC? These duties can be performed by qualified, full-time, on-site staff. 7 - Section 01 91 00 General Commissioning Requirements - It is not clear as to who is responsible to hire and retain the Commissioning Agent (VA or Contractor). Please advise. Contractor is required to appoint an individual, company or firm to act as the Commissioning Agent (01 91 00 1.10 A.) . 8 - Attachment 20 - Price Breakdown sheet is for a project for the Boise VA. Please provided updated price sheet. 9 - SOW 3.7 Contractor shall provide a qualified plumber to check complete installation for conformance to manufacturer s recommendation, to place the system into service, to make all adjustments required for full conformance to specified requirements and to perform all demonstrations and testing. Can this be performed by the installing plumbing contractor or will this have to be an independent 3rd party plumber or Testing & Balance contractor? Note similar requirement reference is also in SOW section 4.1.9. This can be performed by the installing plumbing contractor in both instances. 10 During the site walk we were unable to view Housekeeping Closet in Building 1 Floor 5 Room A531 due to COVID restrictions. Please provide pictures of this space. Will there be any additional measures needed to be in place to perform this work or will this work be scheduled for when COVID restrictions are lifted? See attached pictures. Work can be performed in this area without taking any additional measures beyond the standard COVID and designated ICRA precautions. Work does not need to be scheduled for when COVID restrictions are lifted, it can be completed at any time. 11 The Housekeeping Closet in Building 1 Floor 8 Room B806 is located within the surgery suite and we were unable to view this room during the site walk. Please provide pictures of this space. Will there be any additional requirements (Tyvek suits, gowns, etc.) for when working within in this surgical area?   See attached pictures. Tyvek suits, booties and hair nets must be utilized at all times while in the surgical area, as well as the standard COVID and designated ICRA precautions. Work will have to be performed overnight when the surgery suite is not in use. SITE WALK ATTENDEES 668-22-102 Eyewash Site Walk Attendees Name Company Phone Email Joe Welk Burton 509-362-1755 Toby Thosath Burton 509-468-4932 Peter Hawre Peter Christian, LLC 509-939-7699 Mark Nelson Ascent Mechanical 208-691-7996 markn@ascentmechanicalinc.com Bruce Miller Ascent-Takisaki JV 509-244-7080 brucem@takisaki.com Gary Solberg McClintock & Turk 509-998-9623
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/61c35a3f591b4facad7bfae0ce94750a/view)
 
Place of Performance
Address: Spokane VAMC 4815 N Assembly St, Spokane 99205
Zip Code: 99205
 
Record
SN06222491-F 20220126/220125201430 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.