SOURCES SOUGHT
Z -- Little Goose DC System and LV Switchgear Upgrades
- Notice Date
- 1/25/2022 3:17:53 PM
- Notice Type
- Sources Sought
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- US ARMY ENGINEER DISTRICT WALLA WAL WALLA WALLA WA 99362-1876 USA
- ZIP Code
- 99362-1876
- Solicitation Number
- W912EF22RSS08
- Response Due
- 2/16/2022 4:00:00 PM
- Point of Contact
- David Boone, Phone: 5095277227
- E-Mail Address
-
david.c.boone@usace.army.mil
(david.c.boone@usace.army.mil)
- Description
- The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources for a construction project entitled: Little Goose DC System and LV Switchgear Upgrades.� The work is located at the U.S. Army Corps of Engineers Little Goose Lock and Dam near Starbuck, Washington.� The resulting contract will be a firm fixed-price construction contract.� The North American Industry Classification System (NAICS) code for this project is 238210 Electrical Contractors and Other Wiring Installation Contractors. The associated small business size standard is $16.5 million.�The magnitude of construction for this project is expected to be between $10,000,000 and $25,000,000. This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work.� This is not a solicitation.� Only those firms that respond to this announcement by submitting the following information will be used in determining whether to set aside this requirement.� A list of no more than five current projects at least 50% physically complete or past projects demonstrating technical experience with work of a similar nature to that listed in the Summary Scope of Work.� For each project submitted, provide a brief narrative statement of the work involved, your firm�s role in the project, the dollar value and the completion date. A reference list for each of the projects submitted in 1. above.� Include the name, title, phone number and email address for each reference. Provide a statement of your firm�s business size (HUBZone, Service Disabled Veteran Owned, 8(a), small disadvantaged, or woman-owned) with regards to the NAICS code listed above.� Provide a statement that your firm intends to submit an offer on the project when it is advertised. Provide a statement of your firm�s bonding capacity.� A statement from your surety is NOT required. Cage Code and DUNS number. Submit this information to David Boone, Contract Specialist, via email to david.c.boone@usace.army.mil. �Your response to this notice must be received on or before 4:00 pm Pacific Time on Wednesday, February 16, 2022.� Summary of Scope of Work: This project will upgrade the Direct Current Systems and Low Voltage Switchgear at Little Goose.� The upgrade will improve reliability and align the projects with the Regional Station Service Design Philosophy. Significant features of the upgrades include: � Replacement of the SQ switchgear and associated transformers for SQO, SQ1, and SQ2 � Replacement of unit MCCs SU1 � SU6 � Replacement of MCCs & panels CQO1-CQO5, FCQ1, and FCQ2 � Replacement of battery chargers � Replacement of DC main distribution board SB 1-5 � Replacement of SH switchgear � Reconfiguration of the DC & Preferred AC system one-line � Improvements to the battery room: � � �-battery monitoring system � � �-smoke detector � � �-hydrogen gas detector � � �-battery room differential pressure gage � � �-emergency shower and eyewash water flow detector � � �-fire door and frame � � �-firestopping � � �-fire dampers � � �-replace existing battery room exhaust fan � � �-replacement of the eye wash and shower station � � �-eye wash and shower station drainage � � �-removal of existing concrete pedestals � � �-battery leakage containment system � � �-design of new battery racks that facilitate removal and replacement of batteries � � �-battery spill containment � � �-epoxy floor coating � � �-overhead or other lifting mechanism to facilitate removal and replacement of batteries � � �-new lighting � Provide new permanent load bank for battery capacity testing � All feeder cables will be replaced for new switchgear and MCCs � Replacement of motors and starters for governor oil pumps � Removal of concrete battery pads for 48V and 130V DC batteries; the new batteries will have a standard 8-hour capacity. TECHNICAL EXPERIENCE REQUIREMENTS Installation of low voltage switchgear components and motor control centers Installation of 125VDC equipment including chargers, switchboards and panelboards Post-installation testing and commissioning of equipment All on-site work shall be performed in accordance with the Corps of Engineers Safety and Health Requirements Manual (EM 385-1-1). The Contractor will be responsible for establishing and managing an effective on-site Safety and Health program in accordance with EM 385-1-1 that will require the development and submission of a comprehensive project specific Accident Prevention Plan for Government acceptance.� In addition, the Contractor will be required to develop and submit for Government acceptance Activity Hazard Analyses for each phase of work and a project specific Fall Protection Plan that comply with EM 385-1-1.� A Site Safety and Health Officer (SSHO) employed by the prime contractor shall be required for each shift of the contractor�s on-site operations.� The SSHO shall possess a minimum of 5-years of experience in construction safety on similar projects, shall have completed the 30-Hour OSHA Construction Safety training within the last 5-years, and shall have completed at least 24-hours of formal safety training each year for the past 5-years. The contractor will be required to perform the on-site work in compliance with Government Safe Clearance/Hazardous Energy Control Procedures.� Prior to commencing on-site work, the contractor will be required to complete applicable safe clearance training for all personnel working in areas involved with Hazardous Energy Control.� The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/5b6d376c6e4a4310a9e0a295ff7fe4ce/view)
- Place of Performance
- Address: Starbuck, WA 99359, USA
- Zip Code: 99359
- Country: USA
- Zip Code: 99359
- Record
- SN06224495-F 20220127/220125230111 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |