SOURCES SOUGHT
65 -- Bronchoscope Robotic System
- Notice Date
- 1/28/2022 1:23:21 PM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22L (36C262) LONG BEACH CA 90815 USA
- ZIP Code
- 90815
- Solicitation Number
- 36C26222Q0349
- Response Due
- 2/8/2022 3:00:00 PM
- Archive Date
- 03/10/2022
- Point of Contact
- Reid, Deronte, Contract Specialist, Phone: 240-215-8866
- E-Mail Address
-
Deronte.reid@va.gov
(Deronte.reid@va.gov)
- Awardee
- null
- Description
- THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES-SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources-sought/RFI only. The purpose of this sources-sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1000 Employees). Responses to this sources-sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources-sought, a solicitation announcement may be published. Responses to this sources-sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking Brand Name or Equal Bronchoscope Robotic System that meets the following Salient Characteristics for the Phoenix VA Medical Center: Salient Characteristics/Specification robotic bronchoscope system: o Built in video camera (optic) at distal tip of robotic scope o 2.1mm working channel o LED lights o Built-in fluidics system (suction and irrigation) o Two-part robotic bronchoscope system design with sheath and telescopic scope Robotically controlled sheath (offering articulation, insertion, retraction, parking capabilities) Robotically controlled scope with built in Camera that telescopes from parked sheath (offering articulation, insertion, retraction, parking capabilities) Fused Navigation Technology includes the following: o Optical Pattern Recognition o Electromagnetic Navigation o Robotic Insertion Data **Does not require fluoroscopy for navigation** Key biopsy procedural functions: o Real-time direct & continuous visualization of biopsy process through built in camera (optics) o Always on visualization with simultaneous suction & irrigation capability (using built-in fluidics system feature) Ergonomics design & value of the easy to operate X box type controller function o Physician/operator may sit during navigation instead of standing o Built-in fluidics system (suction & irrigation) with touch of button action(s) o Single-hand bronchoscope/distal tip control, with real-time continuous visualization during live biopsy process Monitor/visualization functions: o Single screen navigation views o Targeting views for precise biopsy guidance o Case planning capability on tower and laptop Product Information: Manufacture Part # Item Description Quantity MON-000006 Monarch Platform, Bronchoscopy 1 Each MBR-000211 Monarch Bronchoscope 5 Each MBR-000014 Biopsy Forceps - Smooth Cup 1 Box MBR-000015 Cytology Brush 1 Box MBR-000218 Bronchoscope Fluidics Tubing 2G 2 Box MBR-000020 Bronchoscope Sheath Valve 1 Box ELEVATE-101020 Premier Support 1 EA The brand name is Auris Health, Inc The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and capable of providing the sought-out supplies, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hub zone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (7) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (8) Please provide general pricing of your products/solution for market research purposes. (9) Please submit your capabilities regarding the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (10) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (11) Please provide your DUNS number. (12) Please provide a list of detail requirements and drawings. *** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items"" meet all required salient characteristics. Responses to this notice shall be submitted via email to Deronte.reid@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Tuesday, February 08, 2022 at 3:00 P.M. PST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice shall not be considered as requests to be added to a prospective bidders list or to receive a copy of the solicitation.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/defc33d3ec994bd6925db735633a25de/view)
- Place of Performance
- Address: Phoenix Veterans Affairs Medical Center 650 E. Indian School Road, Phoenix, AZ 85012, USA
- Zip Code: 85012
- Country: USA
- Zip Code: 85012
- Record
- SN06227839-F 20220130/220129201528 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |