SOURCES SOUGHT
65 -- Diagnostic Sleep System
- Notice Date
- 1/28/2022 6:54:02 AM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 256-NETWORK CONTRACT OFFICE 16 (36C256) RIDGELAND MS 39157 USA
- ZIP Code
- 39157
- Solicitation Number
- 36C25622Q0399
- Response Due
- 2/1/2022 5:00:00 AM
- Archive Date
- 02/11/2022
- Point of Contact
- William Shaver, Contract Specialist, Phone: 601-206-6953
- E-Mail Address
-
William.Shaver@va.gov
(William.Shaver@va.gov)
- Awardee
- null
- Description
- DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 REQUEST FOR INFORMATION 36C25622Q0399 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name or equal products listed in the Statement of Work and Schedule found in the background section below. In the response, please cite business size status. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and DUNS Number. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing these types of supplies. Please include the following: (a) Proof of OEM or OEM distributor of brand name supplies. (b) examples of prior completed Government contracts, references, and other related information. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to William.Shaver@va.gov. Please respond to this RFI no later than 07:00 Central Standard Time on Tuesday, February 1, 2022. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. BACKGROUND: SOW Statement of Work Contract Title: Diagnostic Sleep System Background: This system has been procured by the facility in the past. This item is needed to replace the current system which has reached end of life and is no longer supported by the manufacturer. This system is needed for the application of overnight diagnostic polysomnographic recordings. Scope. The diagnostic sleep system is requested as a replacement for current equipment that has reached end of life and is no longer supported. The system is used to acquire diagnostic data to identify and diagnose sleep disorders. Specifications/Characteristics: Minimum technical specs must be provided: Body position sensor, EEG recording, Chin EMG inputs, EOG channels, ECG channels, pressure transducer, thermal flow, snore microphone, chest/abdominal effort Integrated RIP belt driver Minimum 55 channels Internal memory/data storage Maximum sampling rate 2000Hz/Maximum storage rate 500Hz Pulse oximetry; integrated audio/ video Pan/Tilt/Zoom 20 preset positions, ± 170° pan range, 100°/s pan speed, -30° - 90°/s tilt speed, 18x optical, 12x digital zoom, Guard tour, sequence mode, control queue, supports Windows compatible joysticks, designed for operator control Image Settings Compression, color, brightness, sharpness, contrast, white balance, exposure control, backlight compensation, aspect ratio correction Rotation: 90°, 180°. 270°, text and image overlay, De-interlace filter Audio Input/Output External microphone input or line input, line level output Supported Protocols Ipv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS Processors and Memory ETRAX 100LX, ARTPEC-2, 32 MB RAM, 8 MB Flash Delivery. Address: Gulf Coast Veterans Health Care System 400 Veterans Avenue - Bldg. 26 Warehouse Biloxi, MS 39531 BRAND NAME OR EQUAL: SALIENT CHARACTERISTICS CPAP Unit Alice 6 Diagnostic Sleep System The following are the salient characteristics that will be used to determine if other than the brand name is equal to the item that meets USGS requirements: Headbox Package: Total channels 55 Dedicated EMG channels 5 EEG inputs 19 Chin EMG inputs 3 Automatic chin EMG referencing - Yes EOG channels 2 ECG channels 7 (3 physical and 4 derived) V ECG input Yes Pressure transducer dedicated differential w/snore Flow (thermal) Yes Snore Yes Body position 1 Actimeter inputs 2 Effort (chest/abdominal) zRIP DuraBelt Integrated RIP driver Aux inputs/DC inputs 8 Battery No Signal resolution/bit 16 bit Max sampling rate 2000Hz Max storage rate 500Hz Pulse transit time Yes Electrode interface intuitive image Bedside display No Connectivity Capable (wired Ethernet) Pulse oximetry Masimo Internal memory/data storage 60 GB hard drive Video Networked Audio Integrated with video +VOIP intercom Camera: Image Sensor ¼ ExView HAD CCD Lens 4.1-73.8 mm, F1.3 3.0, auto focus, auto day/night, near focus limit 10 mm (wide) or 800 mm (tele) to infinity, Angle of view, horizontal: 2.7° 48° Minimum Illumination Color mode: 0.3 lux at F1.4, 30IRE, Black/white mode 0.005 lux at F1.3, 30IRE Shutter Time 1/10000 s to 1 s Pan/Tilt/Zoom 20 preset positions, ± 170° pan range, 100°/s pan speed, -30° - 90°/s tilt speed, 18x optical, 12x digital zoom, Guard tour, sequence mode, control queue, supports Windows compatible joysticks, designed for operator control Video Compression MPEG-4 Part 2 (ISO/IEC 14496-2), Motion JPEG Resolution 160x120 to 704x76 Frame Rate MPEG-4 Up to 25/21 fps at 4CIF/2CIFExp, up to 30/25 fps at 2CIF/CIF/QCIF Frame Rate Motion JPEG up to 30/25 fps in all resolutions Video Streaming Simultaneous MPEG-4 and Motion JPEG Controllable frame rate and bandwidth VBR/CBR MPEG-4 Image Settings Compression, color, brightness, sharpness, contrast, white balance, exposure control, backlight compensation, aspect ratio correction Rotation: 90°, 180°. 270°, text and image overlay, De-interlace filter Audio Streaming Two-way (full or half duplex), one-way Audio Compression G.711 PCM 8kHz, G.726 ADPCM 8kHz, Configurable bit rate Audio Input/Output External microphone input or line input, line level output Security Password protection, IP address filtering, HTTPS encryption, IEEE 802.1X network access control Supported Protocols Ipv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS Application Programming Interface Open API for software integration, including VAPIX® from Axis Communications available at www.axis.com Intelligent Video = Video motion detection, audio detection Alarm Triggers Intelligent video, PTZ preset, external input Alarm Events File upload via FTP, HTTP and email, Notification via email, HTTP and TCP, External output activation Video Buffer 9 MB pre- and post-alarm Processors and Memory ETRAX 100LX, ARTPEC-2, 32 MB RAM, 8 MB Flash Power 11 13 V DC max. 14 W Connectors RJ-45 10BASE-T/100BASE-TX, Terminal block for 1 alarm input, 1 output and alternative power connection 3.5 mm mic/line in, 3.5 mm line out Operating Conditions 0 45°C (32-113°F) Humidity 20-80% RH (non-condensing) Approvals EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN 55024, EN61000-6-1, EN61000-6-2, FCC Part 15 Subpart B Class B, ICES-003 Class A, VCCI Class A, C-tick AS/NZS CISPR 22, EN 60950-1, Power, supply: EN 60950-1, UL, CSA Included Accessories Power supply, ceiling mount kit, Installation Guide, CD with installation tools, recording software and User s Manual, Windows decoder 1-user license IR Projector: Wave Length 840nm Beam Spread 56° Range 50 feet Power On Automatic CDS Control Power Consumption 320 mA LED Lifetime Approximately 6000 hours Construction Aluminum Heat Dissipation Built-In fan / Ventilation Holes Operating Temperature - -20° ~ 60°C (-4° ~ 140°F) Power Source 12VDC External lithium battery/ back up power Oximeter adapter for recording of pulse oximetry and heart rate Oxygen connector ports for addition of supplemental oxygen Heated tubing with built in temperature sensor Integrated humidifier Multiple ventilation modes including CPAP, AutoPAP, ASV, Spontaneous, Spontaneous/ Timed, Timed, IVAPS, and pressure control Minimum pressure 3cmH20 Item number Description Quantity 1091375 Alice 6 LDxS Diagnostic Sleep System Bundle 6 1055929 Alice 6 PC Package 6 1055800 Camera, Alice 6 PTZ Package 6 1106684 Network Switch 2 36000 S9 VPAP Tx Clinical System Kit 6
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/1fa042cbe06646eda63d54332f222bbc/view)
- Place of Performance
- Address: Department of Veterans Affairs Gulf Coast Veterans Health Care System 400 Veterans Avenue - Bldg. 26 Warehouse, Biloxi, MS 39531, USA
- Zip Code: 39531
- Country: USA
- Zip Code: 39531
- Record
- SN06227843-F 20220130/220129201528 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |