Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 26, 2022 SAM #7393
SOLICITATION NOTICE

48 -- 48--VALVE ASSEMBLY,MANI

Notice Date
2/24/2022 12:37:38 AM
 
Notice Type
Solicitation
 
NAICS
333999 — All Other Miscellaneous General Purpose Machinery Manufacturing
 
Contracting Office
NAVSUP WEAPON SYSTEMS SUPPORT MECH MECHANICSBURG PA 17050-0788 USA
 
ZIP Code
17050-0788
 
Solicitation Number
N0010420RFB69
 
Response Due
3/1/2022 9:00:00 PM
 
Archive Date
03/17/2022
 
Point of Contact
Telephone: 7176054608
 
E-Mail Address
MICHAEL.THOMAN1@NAVY.MIL
(MICHAEL.THOMAN1@NAVY.MIL)
 
Description
ITEM UNIQUE IDENTIFICATION AND VALUATION (MAR 2016)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|See Sections C and E| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8|x||x|||||| TIME OF DELIVERY (JUNE 1997)|20|0001AA|2|360 days|||||||||||||||||| STOP-WORK ORDER (AUG 1989)|1|| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (DEC 2018)|16|Stand-Alone Receiving Report - Certifications Combo-Receiving and Invoice - Material ||TBD|N00104|TBD|N39040 - Certifications; S4306A - Material|N50286|TBD|Code 133.2|N/A|N/A|N39040 - Certifications|N/A|N/A| See DD 1423 or as specified by block 14a of applicable DD 1423 data items|| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|2|WSS Mechanicsburg|WSS Mechanicsburg| VALUE ENGINEERING (OCT 2010)|3|||| EQUAL OPPORTUNITY (SEP 2016)|2||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)- BASIC (DEC 2019)|2||| INTEGRITY OF UNIT PRICES (OCT 2010)|1|| EQUAL OPPORTUNITY FOR VETERANS (OCT 2015)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|one year after date of delivery|one year after date of delivery||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| SMALL BUSINESS SUBCONTRACTING PLAN (AUG 2017) (DEVIATION 2018-O0018)|5|||||Ross Gertz| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (JUL 2014)|2||| TRANSPORTATION OF SUPPLIES BY SEA (FEB 2019)|2||| BUY AMERICAN --FREE TRADE AGREEMENTS--BALANCE OF PAYMENTS PROGRAM - BASIC(DEC 2017))|5|||||| REQUIREMENTS FOR CERTIFIED COST OR PRICING DATA AND DATA OTHER THAN CERTIFIED COST OR PRICING DATA-MODIFICATIONS (OCT 2010))|7|||||||| VIOLATION OF ARMS CONTROL TREATIES OR AGREEMENTS - CERTIFICATION (JUN 2018)|2||| LIST OF AWARD ATTACHMENTS|5|||||| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (JUN 2019)|11|||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS CERTIFICATE (NOV 2014)|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (NOV 2014)|1|| ROYALTY INFORMATION (APR 1984)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEC 2019)|12|333912|750||||||||||| COST ACCOUNTING STANDARDS NOTICES AND CERTIFICATION (DEVIATION 2018-O0015)(MAY 2018))|1|| REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO SURVEILLANCESERVICES OR EQUIPMENT (AUG 2019))|2||| TYPE OF CONTRACT (APR 1984)|1|firm-fixed-price | ALTERATIONS IN SOLICITATION (APR 1984)|3|||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2|x|| REQUIREMENTS FOR CERTIFIED COST OR PRICING DATA AND DATA OTHER THAN CERTIFIEDCOST OR PRICING DATA--BASIC (JUN 2019))|1|| 1.This amendment is being issued to increase the quantity from 2 to 4 and to update the TDP from version 009 to 010. 2.There is no option CLIN for this requirement. References: (a) NAVSUP WSS (POC Ross Gertz) email dated 28 May 2020 (b) VACCO Industries Procedure Qualification Record (PQR) VI-PQR-057 Revision -dated 6 October 2015 (c) VACCO Industries PQR VI-PQR-020 Revision - dated 18 July 2012 (d) VACCO Industries Weld Procedure Specification (WPS) 8-8-GTA-GIII Revision Edated 31 January 2019 (e) VACCO Industries Welding Information Document WI-S1E10068 Revision A (f) VACCO Industries PQR VI-PQR-023 Revision - dated 25 June 2013 (g) VACCO Industries WPS 17-4-8-GTA-SII Revision B dated 16 October 2014 1. Reference (a) requests approval of references (b), (c), and (d) on behalf of VACCO Industries for the subject Request for Quotation (RFQ). 1a. In responseto reference (a), references (b) and (c) are approved by NAVSEALOGCEN. The associated WPS, reference (d), may be used to weld the locating pin (base 1, P/N F2C10178-3AF-1) to the disc compressor (base 2, P/N F2C10178-3AF-2) on reference (e) for the subject RFQ and subsequent contract only. 2. Reference (a) requests approval of references (f) and (g) on behalf of VACCO Industries for the subject RFQ. 2a. In response to reference (a), reference (f) is approved by NAVSEA. The associated WPS, reference (g), may be used for a lock weld between the socket head cap screw (base 1, P/N V2B11193-4MF) and the disc retainer (base 2, P/N V2C11683-3EA) onreference (e) for the subject RFQ and subsequent contract only. 3. The following information is provided in addition to the above approvals: 3a. The approval given in Paragraphs 1 and 2 above does not mitigate the vendor'sresponsibility to comply with the provisions of S9074-AQ-GIB-010/248, S9074-ARGIB-010/278, and the contract. References (b), (c), and (f) are approved and references(d) and (g) are authorized for use on only the welds specified in Paragraphs 1 and 2,above; any other welds will require submission of a separate WPS and PQR forapproval. 3b. Procedures with approved qualification data reports are acceptable for production welding or casting repair as applicable, but cannot be used for special repair of casting, repair of wrought materials, or repair of forged materials without an approved waiver request from the PCO (Procurement Contracting Officer) to weld repair. This requestfor waiver shall be submitted on Form LI/SS WD-1 describing the defect and indicatingsize, depth, and location. This request shall also include a description of the proposed repair. 4. All other terms and conditions remain unchanged. 1. This procurement is a TRIPER procurement and in accordance with Federal Law,DoD and Navy policy, and in conjunction with the Defense Priorities andAllocation System, this contract shall be rated ""DX."" 2. DD 1423 Data Item A001 may be waived if on file with NAVSUP WSS. 3. All contractual documents (i.e. contracts, purchase orders, task orders, andmodifications) related to the instant procurement are considered to be ""issued""by the Government when copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commerce methods, such as email. The Government's acceptance of the contractor's proposal constitutes bilateral agreement to ""issue"" contractual documents as detailed herein. 4. Submission of all certification DD1423 Data Contract Data Requirements Lists(CDRLs) will be on or before 20 days prior to delivery. PNSY Review/Acceptance of certifications CDRLs will be 6 working days after receipt of certification DD1423 CDRLs. Final delivery of material will be on or before 360 days after contract effective date. 5. CDRL ITEM Timeline Delivery Method Submission of Weld Data and PQR Data---120 days ADC---LT Approval of Weld Data---60 days after receipt \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 ""Document References"" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.2 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;F3C10089 99517 M B S1E10068 99517 AA B S3C10011 99517 K B S3C10012 99517 K B S3C10013 99517 K B V3E10048 99517 E B V3D10054 99517 H B V3D10055 99517 J B V3D10269 99517 B B ATP-S1E10068 99517 H B WI-S1E10068 99517 A B 2.3 Specification Revisions - The specification revisions listed under ""Docu ments References"" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FF-S-86 | | |E |910116|A| 4| | DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=MMM-A-132 | | |B |940401|A| | | DOCUMENT REF DATA=ASTM-A182 | | |A |191101|A| | | DOCUMENT REF DATA=ASTM-A240 | | | |191201|A| | | DOCUMENT REF DATA=ASTM-A484 | | | |190901|A| | | DOCUMENT REF DATA=ASTM-A581 | | |B |950910|A| | | DOCUMENT REF DATA=ASTM-A582 | | | |170315|A| | | DOCUMENT REF DATA=ASTM-F606 | | | |191115|A| | | DOCUMENT REF DATA=TT-P-645 | | |B |900312|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-DTL-1222 | | |J |001208|A| | | DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=SAE AMS 5643 | | |V |180101|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=MIL-DTL-15024 | | |G |180303|A| | | DOCUMENT REF DATA=MIL-DTL-15090 | | |E |101012|A| | | DOCUMENT REF DATA=MIL-C-15726 | | |F |911008|A| 1| | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-C-24679 | | | |880506|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=SAE AMS-QQ-S-763 | | |D |150301|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | | |950801|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 ;Pressure reducing manifold assembly, to be in accordance with Vacco drawing S1E10068, part number S1E10068-13 With Vacco welding Information document WI-S1E10068, except as amplified or modified herein.; 3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: ;Vacco drawing S1E10068; Part - ;body, item 1; Material - ;SAE-AMS-QQ-S-763, class 304, condition A (Altenative material ASTM-A182 or ASTM-A240); Part - ;filter cap, item 2, port adapter (inlet), item 3 and port adapter (outlet), item 7 and tube, item 8; Material - ;ASTM-A582, type 303; Part - ;plug, item 4; Material - ;ASTM-A582 and ASTM-A581, type 303; Part - ;inlet port, item 12; Material - ;Thread piece, SAE-AMS-QQ-S-763, class 316L, condition A and tail piece, SAE-AMS-QQ-S-763, class 304; Part - ;outlet port, item 13; Material - ;SAE-AMS-QQ-S-763, class 316L, condition A and tailpiece, MIL-C-15726 or MIL-C-24679, alloy C71500; Part - ;relief port, item 14; Material - ;thread piece SAE-AMS-QQ-S-763, class 316L, condition A and tailpiece, MIL-C-15726 or MIL-C-24679, alloy C71500; Part - ;socket head cap screws, items 23, 28, 29, 30 and 32; Material - ;SAE-AMS 5643, condition H-1025; Part - ;socket head cap screw, item 27; Material - ;300 series per SAE-AMS-QQ-S-763 or ASTM-A582; Part - ;socket head cap screws, items 31 and 34; Material - ;300 series per FF-S-86; ;Guage connector assembly to Vacco drawing S3C10013, part number S3C10013-01 (item 5 of drawing S1E10068); Part - ;body, item 1; Material - ;300 series per SAE-AMS-QQ-S-763 or ASTM-A484 and ASTM-A582; Part - ;stem, item 2; Material - ;SAE-AMS 5643, condition H-1025; ;Bleed block assembly, Vacco drawing S3C10012, part number S3C10012-01 (item 6 of drawing S1E10068); Part - ;body, item 1; Material - ;300 series per SAE-AMS-QQ-S-763 or ASTM-A582; Part - ;stem, item 2; Material - ;SAE-AMS 5643, condition H1025; ;Regulator, Vacco drawing V3E10048, part number V3E10048-02, with VACCO Welding Information Document WI-S1E10068 (item 15 of drawing S1E10068); Part - ;seat retainer, item 2, guide, item 17; Material - ;SAE-AMS 5643, condition H-1025; Part - ;seat plate, item 10; Material - ;SAE-AMS 5643, condition H-1150; Part - ;dome cap, item 21; Material - ;ASTM-A582, type 303; Part - ;plug, item 29; Material - ;300 series per SAE-AMS-QQ-S-763 or ASTM-A582; Part - ;plug, item 30; Material - ;SAE-AMS-QQ-S-763, class 304; Part - ;socket head cap screw, item 28; Material - ;FF-S-86, 300 series; ;Block assembly Vacco drawing S3C10011 (item 8 of of drawing V3E10048); Part - ;body, item 1; Material - ;300 series per SAE-AMS-QQ-S-763 or ASTM-A582; Part - ;stem, item 2; Material - ;SAE-AMS 5643, condition H-1025; ;Differential pressure indicator, Vacco drawing F3C10089, part number F3C10089-070 (item 20 of drawing S1E10068); Part - ;body, item 1, bonnet, item 4 and adjusting screw, item 9; Material - ;ASTM-A582, type 303; ;INLET valve Vacco drawing V3D10055, part number V3E10055-01 (item 16 of drawing S1E10068); Part - ;poppet, item 3; Material - ;SAE-AMS 5643, condition H-1025; Part - ;bonnet, item 4; Material - ;ASTM-A581 or ASTM-A582, type 303, condition A; ;Outlet valve, Vacco drawing V3D10054, part number V3D10054-01 (item 17 of drawing S1E10068); Part - ;bonnet, item 1; Material - ;ASTM-A581 or ASTM-A582, type 303, condition A; Part - ;poppet, item 3; Material - ;SAE-AMS 5643, condition H-1025; ;Relief valve Vacco drawing V3D10269, part number V3D10269-05 (item 18 of drawing S1E10068); Part - ;body, item 1; Material - ;ASTM-A582, type 303; Part - ;poppet, item 3; Material - ;SAE-AMS 5643, condition H-1025; Part - ;port adapter, item 28; Material - ;ASTM-A582, type 303; Part - ;socket head cap screw, item 31; Material - ;SAE-AMS 5643, condition H-1025; ;By-pass valve Vacco drawing V3D10055, part number V3D10055-02 (item 21 of drawing S1E10068); Part - ;poppet, item 3; Material - ;SAE-AMS 5643, condition H-1025; Part - ;bonnet, item 4; Material - ;ASTM-A581 or ASTM-A582, type 303, condition A; 3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below. Test - Intergranular Corrosion Test (Only for SAE-AMS-QQ-S-763, Classes 304-condition A, 304L, 316-condition A, 316L, 317-condition A, 321 and 347 material. Test must be performed prior to fabrication/machining) Item - ;Drawing S1E10068, body, item 1, thread pieces, item 12, 13 and 14 and tailpiece item 12 and socket head cap screws, item 27. Drawing S3C10013, body, item 1. Drawing S3C10012, body, item 1. Drawing V3E10048, plugs items 29 and 30 and Drawing S3C10011, body, item 1; Performance - SAE-AMS-QQ-S-763 Acceptance - SAE-AMS-QQ-S-763 Test - ;Liquid Penetrant Inspection; Item - ;All fasteners requiring chemical and mechanical certification; Performance - T9074-AS-GIB-010/271; Sampling must be per MIL-DTL-1222 Acceptance - MIL-DTL-1222 Test - ;Acceptance tests; Item - ;each assembly; Performance - ;In accordance with ATP-S1E10068; Acceptance - ;In accordance with ATP-S1E10068; Test - ;Visual Inspection (root layer); Item - ;Class M-2 Weldments; Performance - ;T9074-AS-GIB-010/271; Acceptance - ;MIL-STD-2035; Test - ;Visual Inspection (final layer); Item - ;Class M-2 Weldments; Performance - ;T9074-AS-GIB-010/271; Acceptance - ;MIL-STD-2035; Test - ;Visual or Dye Penetrant Inspection (root layer); Item - ;Class P-1 Weldments; Performance - ;T9074-AS-GIB-010/271; Acceptance - ;MIL-STD-2035; Test - ;Visual and Dye Penetrant Inspection (final layer); Item - ;Class P-1 Weldments; Performance - ;T9074-AS-GIB-010/271; Acceptance - ;MIL-STD-2035; 3.4 Component Identification Description (CID) - When applicable drawing(s) and/or specification(s) specify that a nameplate or identification plate is required, the CID number ( ;CID T887355399; ) must be added. When no plate is specified, an identification plate in accordance with MIL-DTL-15024, Type ""C"" on brass or Type ""H"" on aluminum must be securely attached to each assembly showing the above CID number. No assembly must be shipped without the CID number attached. 3.5 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG/-0PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of thesmallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. 30 minutes / - 0 minutes. above 2500 PSIG, the pressure tolerance must be +2%/-0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes. For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be + 60 minutes/- 0 minutes. 3.6 Welding or Brazing - When welding, brazing, and allied processes are required, they must be in accordance with S9074-AR-GIB-010A/278, (S9074-AQ-GIB-010/248 for brazing) by personnel and procedures qualified under S9074-AQ-GIB-010/248 for all production and repair welding and brazing. Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.7 Wedge Tensile Test Specimens (Headed fasteners) - A wedge tensile test must be conducted on a Full Size Fastener for each production lot and reported aspart of the Mechanical Properties. The required specimens for the Wedge Tensile Test must be separate fasteners from those required for the Yield Test. 3.7.1 Testing for Socket Head Cap Screws must be in accordance MIL-DTL-1222, paragraphs 4.5.2.3 and 4.5.2.3.1. 3.7.2 Testing for all other Headed Fasteners with a nominal diameter greater than 1/4-inch must be in accordance with ASTM-F606 for grades 5, 8, B7, and B16.For all other grades, the following wedge angles must be used. a. Except as specified in item c below, fasteners with a nominal diameter of 1/4-inch through 1-inch (inclusive) must be tested with a ten degree wedge. b. Except as specified in item c below, fasteners with a nominal diameter over 1-inch must be tested with a six degree wedge. c. Fasteners that are of grades 8, B7, B16, 410, 416, 416Se, 431, and 630 and are threaded within one diameter to the underside of the head must be tested as follows: Sizes 1/4 inch through 3/4 inch (inclusive) Use a six degree wedgeSizes over 3/4 inch Use a four degree wedge d. Fasteners which have passed testing with wedge angles greater than those specified should be considered acceptable. 3.7.3 For fasteners having a length less than the minimum specified in Table 1 of ASTM-F606, one ""test specimen fastener"" must be manufactured from each lot of fasteners and tested to represent that lot. The length of these test specimen fasteners must meet the minimum specified in table 1 of ASTM-F606 but must not exceed it by more than 1/4 inch. Test specimen fasteners must be the same type, style, and diameter as the production lot and must be manufactured from the same starting material, using the same manufacturing techniques as the production lot, and must be heat treated (if required) along with the production lot. 3.8 Thread Inspection Requirements - All threads on threaded parts must be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable. 3.8.1 System 21 of FED-STD-H28/20 must be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement. 3.8.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 must be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222. 3.8.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system. 3.9 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.10 Component Identification - A Triper serial number will be assigned to each component and a nameplate will be provided by NAVSUP WSS MECH, Code N97121, as Government Furnished Equipment (GFE) prior to packaging and shipment. The Contractor is requested to notify NAVSUP WSS MECH, Code N97121, when the manufacturing process is ready for the nameplate(s), allowing sufficient time for mailing. Individual serial numbers must to be stamped onto nameplate using 3/16"" letters and filled with red paint prior to installation on the components. Nameplates should be attached in the locations specified on the drawing provided for this purpose, utilizing an epoxy compound which meets the requirements of Federal Specification MMM-A-132. The manufacturer's instruction should be followed to ensure proper adhesion. Subsequent to installation, painted surfaces adjacent to the nameplate should be touched up with primer equivalent to TT-P-645 and one coat of light gray paint equivalent to MIL-DTL-15090. Prior to shipment, each packaging container must have the appropriate Triper program serial number marked externally as follows: ""TRIPER PROGRAM MATERIAL"" SERIAL NUMBER - ______ 3.11 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.11.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. 3.12 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.12.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.12.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted using the ECDS (Electronic Contractor Data Submission) system at https://register.nslc.navy.mil/ 3.12.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.13 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. 3.14 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.15 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.16 See CDRLs DI-MISC-80875 (Welding Procedures) and DI-MISC-80876 (Weld Procedure Qualification Data) - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds. 3.16.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.16.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. ""WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC."" ""WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ.""). Authority for the repair of Special Repairs in castings and authority for the repair of wrought or forged material must be obtained from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.16.3 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 48 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 48 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.16.4 When drawings require hard facing surface Iron content (Nickel for Monel valves) notto exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.16.5 Qualification requirements for production hardfacing: The maximum qualified thickness for hardfacing must be twice the weld deposit thickness measured in the as-welded condition that is subjected to initial NDT (Non-Destructive Testing) and any additional drawing requirements. The minimum qualified thickness is the final machined thickness at which hardness testing, NDT, macro-etch, and any additional drawing requirements are satisfactorily performed. 3.16.6 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.16.7 Qualification requirements for production cladding: The maximum qualified thickness for cladding must be twice the weld deposit thickness measured in the as-welded condition that is subjected to initial NDT and any additional drawing requirements. The minimum qualified thickness is the final machined thickness at which NDT, side bends, macro-etch testing, and any additional drawing requirements are satisfactorily performed. 3.16.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.16.9 See CDRL DI-MISC-80678 (Consumed Weld Metal) - A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms t...
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8dd7dba17d8b4711a43ba480bcee3cbf/view)
 
Record
SN06250410-F 20220226/220224230059 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.