SOURCES SOUGHT
H -- HVAC Air Test/Balance Service
- Notice Date
- 2/25/2022 12:12:50 PM
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
- ZIP Code
- 80111
- Solicitation Number
- 36C25922Q0195
- Response Due
- 3/4/2022 1:00:00 PM
- Archive Date
- 05/03/2022
- Point of Contact
- Frankie Emler, Contract Specialist, Phone: 918-577-3923
- E-Mail Address
-
Frances.Emler@va.gov
(Frances.Emler@va.gov)
- Awardee
- null
- Description
- HVAC Testing, Adjusting & Balancing Services Montana VA Health Care System Fort Harrison, MT PURPOSE: Montana VA Health Care System requires the contractor to provide to provide HVAC Testing, Adjusting and Balancing (TAB) services in support of Ft Harrison VAMC., in accordance with this PWS, in an efficient and cost-effective manner, supporting the VA mission. The contractor shall provide all personnel, supplies, supervision, tools, materials, equipment, transportation and other items and non-personal services necessary to provide TAB services in accordance with this Performance Work Statement (PWS) except as those items specified as government furnished property and services. The contractor shall perform to the standards in the contract as well as all local, state and federal regulations. The Contractor shall provide airflow Test and Balance (TAB) for Ft Harrison Cheyenne VA Medical Center (the Facility) located at 3687 Veterans Drive., Ft Harrison MT 59636. Services provided by the Contractor must enable the Facility to achieve Joint Commission airflow compliance and assist in maintaining the Facility in proper operational condition. Approximately 30 spaces of the facility will be TAB D on an annual basis and a separate SPS TAB Report will be provided to the facility. CREDENTIALS: Test and balance contractor shall be NEBB certified and have a minimum of three years experience in the test and balance (TAB) trade. Technician performing work must have a minimum of three years experience with healthcare facilities and be familiar with VA or other Federal Government facilities and procedures. Certification must be provided. COMPLIANCE: The contractor shall be fully responsible for compliance with all VA, local, state, and Federal environmental/occupational safety laws, rules and regulations. The contractor shall follow life and safety codes and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients. The contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working processes; example: lockout/tagout. All work for the duration of the contract shall be performed by trained technicians. All safety measures shall be approved as adequate by the safety officer in advance. The contractors shall follow VA badging requirements so they may provide unescorted services around the facility. Contractors will be escorted by VA personally in secured department or sensitive areas as needed. TASK AND REQUIREMENTS: The Contractor shall provide TAB services to maintain the Facility in operational compliance with Joint Commission requirements. As-builts of existing HVAC systems for the TAB contractor s use will be provided to the successful contractor upon contract kickoff. If the TAB contractor encounters existing conditions that differ from the plans provided, they shall redline the plans and return to the VA. The TAB contractor shall reference the VA HVAC Design Manual (available at this link: https://www.cfm.va.gov/til/dManual/dmHVAC.pdf) to determine and calculate the number of Air Changes per Hour (ACH) and the number of outside-air ACH for all spaces. The contractor shall be responsible for measuring the spaces to obtain room volume needed to perform these calculations. They shall also use the VA HVAC Design Manual document to determine the pressure relationship requirement between spaces. The required air change rates and pressure relationship requirements shall be clearly indicated on the TAB report along with the actual readings for comparison. Any space not meeting requirements shall be clearly identified and a separate Deficiency Report will be produced for all the spaces not meeting air change and/or pressure relationships in accordance with the VA HVAC Design Manual requirements. The TAB report shall include details for each space including room number, room name, system served by, required air change rate, and required pressure relationship/ differential. Note any observed device deficiencies in the report such as broken or out of adjustment drive belts, misaligned sheaves, excessive noise, vibration, dirty coils, dirty filters, etc. After VA has reviewed the Deficiency Report and provided feedback as needed provide corrective balancing of air systems and spaces identified as deficient. Service Area Room Number Surgery 217B, 210, 212 SPS 220 (Sterile Core), 226 (Men s Locker Room), 228 (Women s Locker Room), 222 (Prep & Pack), 22 (Ante Room), 221 (Gross Decontamination), 206 (Medivator Cleaning), 136A (Nuke Med), 136 (Nuke Med Hot Room) Satellite Storage 363D (Endoscope storage), 102S (Dental Storage), Gold 83 (Gold Clinic Storage), Gold 94 (Gold Clinic Storage), A87 (Emergency Room Storage), 127 (Cath Lab) Endoscopy Procedure Rooms 363A (Endoscopy), 363E (Endoscopy) Negative Pressure Rooms ICU 1 (ICU Bed 1), ICU 6 (ICU Bed 6), 308 (Same Day Surgery), 325 (Ward), 410 (Ward), 415 (Ward), 465 (Ward), 470 (Ward), 470 (Ward), 33 (Emergency Dpt), 17 (Compounding Room) IMPORTANTR NOTE: This Sources Sought is for information only (to determine the socioeconomic status of interested companies). No award will be made off of this posting. LIMITATIONS OF SUBCONTRACTING: The Limitations of Subcontracting may or may not apply to a resulting solicitation from this Market Research. Vendors are advised to familiarize themselves with Federal Acquisition Regulation parts 19.505(a)(2) and 19.505(b)(1) as it pertains to subcontracting limitations. Vendors are also advised to familiarize themselves with 13 CFR 125.6 and the penalties described in this regulation. Please communicate via e-mail to Frances.Emler@va.gov by COB March 4, 2022 as to your company s interest and ability to perform service per this brief Scope of Work. If interested, please provide the following: Please state your company s business size as related to NAICS code XXXXXX As per the Limitations of Subcontracting: (see FAR 19.505) As Primary Contractor: what % of Total Contract Value will you retain? If using a Subcontractor: what % of Total Contract Value will go to them? Please provide DUNS number If you have an FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable In order for you company s information to be counted in relation to this Market Research all above questions must be answered.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/2e78dc251f424fd99e7b6d73b5baf464/view)
- Place of Performance
- Address: Department of Veterans Affairs Montana VA Health Care System 3687 Veterans Drive, Fort Harrison, MT 59636, USA
- Zip Code: 59636
- Country: USA
- Zip Code: 59636
- Record
- SN06251683-F 20220227/220225230114 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |