SOURCES SOUGHT

Z -- Fire Alarm and Notification System Replacement

Notice Date
3/11/2022 6:30:56 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
PBS R5 CHICAGO IL 60604 USA
 
ZIP Code
60604
 
Solicitation Number
236220SS
 
Response Due
3/30/2022 1:00:00 PM
 
Archive Date
12/31/2023
 
Point of Contact
Roger Schulte, Phone: 2166452280, Martin L. Harris, Phone: 2174925041, Fax: 2174925046
 
E-Mail Address
roger.schulte@gsa.gov, martin.harris@gsa.gov
(roger.schulte@gsa.gov, martin.harris@gsa.gov)
 
Description
Source Sought Notice- Fire Alarm and Notification System Replacement, Columbus, Ohio-�Response Due March 30, 2022, by 4pm EST THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a Request for Proposal. This notice does not represent a commitment by the Government to issue a solicitation or award a contract. This is strictly market research to determine availability and adequacy of potential sources with the capabilities and experience to perform the required work. The Government is not obligated to and will not pay for information received as a result of this announcement. Request for solicitation will not receive a response. The General Services Administration (GSA), Great Lakes Region (Region 5), has a need to perform the following work which includes, but is not limited to: Replacement of the fire alarm system in the Federal Building and the Federal Building Garage at the John F. Bricker Federal Building and U.S. Courthouse, located at 200 North High Street Columbus, Ohio 43215.� The construction cost is between $1,000,000 and $5,000,000. The performance period is 357 calendar days for the Federal Building and 140 calendar days for the Garage. The anticipated award date is September 2022. � Additional Information:� � The contractor will be required to demonstrate that they have successful past performance record in Fire Alarm Projects. �If the work will be performed by a subcontractor, the Contractor will be required to identify the subcontractor and provide installations where this subcontractor together with the contractor has successfully installed such systems. The work includes: � �Designing and providing a modified, complete, automatic sprinkler system as described herein and on the contract drawings for the Bricker U.S. Federal Building and Garage. The system shall include all piping, sprinklers, fittings, hangers, valves, and all other accessories and miscellaneous items required for a complete operating system even though each item is not specifically mentioned or described. The new sprinkler system shall be tested and ready for full operation prior to acceptance by the Government. The fire protection system shall be restored to normal operations at the end of each work shift. Extent of the Work: The system shall be modified to accommodate the related fire alarm work to the Bricker U.S. Federal Building and Garage. The system shall be modified in locations in accordance with the drawings, specifications and referenced publications. Compliance: The entire automatic sprinkler system shall be designed in accordance with Section 1.4 A. Any reference to ""authority having jurisdiction"" shall be interpreted to mean the GSA Regional Fire Protection Engineer. All material and equipment used shall be listed or approved by Underwriters Laboratories (UL), Factory Mutual (FM) or Intertek, for their intended use and service. Interested ?rms should submit the below information to Roger Schulte, Contract Specialist, at roger.schulte@gsa.gov. An electronic submission is required. Your submission should be no longer than 10 single sided pages.� 1) A short statement regarding your business' expertise and experience in this field. 2) Include two projects completed within the last ?ve years similar in size and scope to the work described above.� Provide at least two examples of similar projects. Was the installation done by the Contractor or a Subcontractor. If Subcontractor, identity the subcontractor. � � � �B) Were the projects completed at least 3 years ago? � � � �C) Was the installation supervised by a technician that is certified NICET level III or IV for fire alarms, or a registered fire protection engineer? Is this individual on staff or was this subcontracted? Include any other relevant information. 3) Provide a customer point of contact for each project listed (telephone and email address). 4) Do you have experience working in a historic building for similar size and scope described above? If yes, please explain and provide a customer point of contact (telephone and email address). 5) Indicate any and all applicable small business representation(s) (8(a), HUBZone, Service-Disabled Veteran Owned, Women-Owned, etc.). 6) What is your firm's bonding capacity per project? 7) Please indicate your intent to bid on a subsequent solicitation.� All information submitted will be subject to veri?cation and additional information may be requested to substantiate responses. An electronic submission is preferred. Your submission should be no longer than 10 pages.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/fa560ef02299440f855c2141c388d5e8/view)
 
Place of Performance
Address: Columbus, OH 43215, USA
Zip Code: 43215
Country: USA
 
Record
SN06265198-F 20220313/220311230107 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.