SPECIAL NOTICE
J -- Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Synopsis
- Notice Date
- 3/31/2022 2:57:59 PM
- Notice Type
- Special Notice
- NAICS
- 561621
— Security Systems Services (except Locksmiths)
- Contracting Office
- W6QM MICC-JB LEWIS-MC CHORD JOINT BASE LEWIS MCCH WA 98433-9500 USA
- ZIP Code
- 98433-9500
- Solicitation Number
- W911S822R0004JBLM
- Response Due
- 5/6/2022 2:00:00 PM
- Archive Date
- 05/06/2024
- Point of Contact
- Scott A. Byrd, Phone: 2534775435, Thomas Williams
- E-Mail Address
-
scott.a.byrd.civ@mail.mil, thomas.r.williams60.civ@mail.mil
(scott.a.byrd.civ@mail.mil, thomas.r.williams60.civ@mail.mil)
- Small Business Set-Aside
- 8A 8(a) Set-Aside (FAR 19.8)
- Description
- The Mission and Installation Contracting Command Installation Contracting Office, Joint Base Lewis McChord is issuing this synopsis for Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair for Joint Base Lewis-McChord (JBLM) and Yakima Training Center.� The Contractor shall provide all personnel, equipment, tools, materials, supervision, and personnel services necessary to examine, restore, maintain, repair, clean, inspect, and test the following: installed facility fire sprinkler systems, kitchen fire suppression systems, fire pumps, fire pump monitoring devices and related equipment, fire sprinkler monitoring devices, aircraft hangar Aqueous Film Forming Foam (AFFF) systems (to include annual lab testing of the foam concentrate agent), automatic fire alarms, Fire Alarm Control Panels (FACP) including the software and associated devices, (activation, warning and auxiliary), and electrical/electronic components of the systems. The Contractor shall provide testing and programming to facilities with Mass Notification Systems (MNS). The Contractor shall provide updated Computer-Aided Design (CAD) (current year) drawings in a manner that will ensure fire systems serviceability and proper operation. Contractor shall provide a list of major component�manufacturers and system components, year of installation as near as can be determined, as well as ITM cycle for sprinkler and suppression systems. Contractor shall submit reports to the Contracting Officers Representative (COR) at JBLM, Washington (WA) and leave a copy of the CAD drawing at the FACP in each building. All work shall comply with and be in accordance with (IAW) the Unified Facilities Criteria (UFC) 3-601-02 Operations and Maintenance: Inspection, Testing, and maintenance of Fire Protections Systems, National Fire Protection Association (NFPA) Standards 10 through 25, 70, 72, 96, JBLM requirements and the manufacturer�s instructions. The Unified Facilities Criteria (UFC) 3-601-02 shall take first precedence over other guidance. Technical Exhibit 1 (TE-1) shows the JBLM and YTC, WA facilities list. Offerors are reminded to carefully review solicitation documents issued as criteria as stated in the solicitation shall govern. The solicitation will be issued in electronic format only on or around 8 April, 2022 and will be available on the Internet at: https:www.sam.gov. It is the Offeror�s responsibility to check the www.sam.gov website provided as necessary for any posted changes to this solicitation and all amendments.� Solicitations, samples and additional required documentation must be submitted on or before the close date noted in the solicitation.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/3fe5c6897095478a98ca3ee93eb7df75/view)
- Place of Performance
- Address: Joint Base Lewis McChord, WA 98433, USA
- Zip Code: 98433
- Country: USA
- Zip Code: 98433
- Record
- SN06285271-F 20220402/220331230103 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |