Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 05, 2022 SAM #7431
SOLICITATION NOTICE

Y -- DESC 20UX Install Additive Injection System

Notice Date
4/3/2022 5:54:53 PM
 
Notice Type
Presolicitation
 
NAICS
237120 — Oil and Gas Pipeline and Related Structures Construction
 
Contracting Office
US ARMY ENGINEER DISTRICT JPN APO AP 96338-5010 USA
 
ZIP Code
96338-5010
 
Solicitation Number
W912HV22R0008
 
Response Due
4/17/2022 10:00:00 PM
 
Point of Contact
Ryan Marzetta, Phone: 0464078725 / 3152638725, Jennifer H. Knutson, Phone: 0464078839
 
E-Mail Address
ryan.j.marzetta.civ@usace.army.mil, jennifer.h.knutson.civ@usace.army.mil
(ryan.j.marzetta.civ@usace.army.mil, jennifer.h.knutson.civ@usace.army.mil)
 
Description
The U.S. Army Corps of Engineers, Japan District (POJ) is providing a PRESOLICITATION notice pursuant to FAR 36.213-2.� This is not a solicitation. PROJECT INFORMATION: Project Title: FY22 DLA DESC20UX Add/Rpr Additive Injection System, Misawa Air Base, Japan Project Location: Misawa Air Base, Japan Project FSC: Y1NA � Construction of Fuel Supply Facilities Project NAICS: 237120 - Oil and Gas Pipeline and Related Structures Construction Project Magnitude: Between �100,000,000 and �500,000,000 Japanese YEN Project Description: Construct an Additive Injection System to mechanically inject Fuel System Icing Inhibitor (FSll), Corrosion Inhibitor/Lubricity Improver (CI/LI), and Static Dissipater Additive (SDA) to convert Jet A-1 to military specification JP-8 fuel. The system will include two 15,000-gallon FSII storage tanks, one 550-gallon CI/LI tank and one 75-gallon SDA tank for additive storage. The storage tanks will be double-wall stainless steel additive storage tanks on concrete pads. Provide Automatic Tank Gauging (ATG) system for the tanks. Stainless steel piping will convey additives from the transfer equipment to the additive storage tanks and from the additive storage tanks to the additive mixing tanks and injectors inside Building 1150., mixing tanks with mixers for dilution of CI/LI and SDA, two injectors, and piping additions and modifications to the existing fuel piping within existing Filter Building 1150 at Tank Farm 2. The piping additions and modifications will be configured to allow additive injection when receiving fuel from either the truck offload facility or from the Hachinohe pipeline. Modify existing Building 1150 by demolishing existing window and cast-in place concrete wall below in order to provide a hollow metal door and frame. Provide an emergency eye wash and shower inside the building. Provide a fire sprinkler system for the Filter Building in accordance with current Unified Facility Criteria (UFC) fire protection requirements. Construct a two-room enclosed building addition to Building 1150. One room will house electrical equipment and the second room will house a fire protection sprinkler riser. Site preparation includes site clearing and grubbing work and site earthwork. Paving and site improvements include a truck offload pad with containment curbs and a remote spill containment basin, additive transfer equipment pad, asphalt-concrete roadways, site demolition, and landscaping. Mechanical utilities include a new water line to the fire protection sprinkler system, a water service lateral connection for the emergency eye wash and shower at Building 1150, and a wash water holding tank for drainage from the eye wash and shower. Electrical utilities include primary electrical power distribution, secondary power distribution, transformers, exterior area lighting, grounding, and telecommunications distribution. This project shall require specific commissioning of the fueling system. The commissioning should be give particular attention. Draft options that are subject to change are as follows: Specifications include UFGS 33 08 55 Commissioning of Fuel Facility Systems. This specification section has been modified to include government furnished fuel and additive chemicals to be utilized to perform the flushing, cleaning, and performance testing. The Government anticipates the Period of Performance will be 361 calendar days.� SOLICITATION INFORMATION: Procurement Method: The Government will issue a Request for Proposal (RFP) Solicitation utilizing the Lowest Price Technically Acceptable source selection procedures.� � The Governments anticipates issuing the solicitation no later than 30 April 2022.� The solicitation when issued, will identify the proposal submission instructions.� All solicitation documents, drawings, and specifications will be posted on Beta.SAM.Gov when issued.� It is the responsibility of interested vendors to monitor Beta.SAM.Gov for issuance of the solicitation and/or amendments.� � The Government intends to award a firm-fixed-price construction contract as a result of the RFP.� �� A virtual telephonic pre-proposal conference has been scheduled for: 1. Date and Time: Monday, 9 May 2022 at 09:00 AM, Japan Standard Time (JST). 2. Those who wish to attend shall send a notification no later than 29 April 2022, JST to the POCs identified in paragraph (c)3 below with a list of names that will call into this virtual telephonic pre-proposal conference. Upon receipt of the notification, instructions and the call-in number will be provided before 9 May 2022. SITE VISIT An organized site visit has been scheduled for-- Date and Time: 11 May 2022 at 10:00 AM, Japan Standard Time � Due to circumstances concerning the COVID-19 pandemic, the scheduled site visit is subject to social distancing measures. Location of meeting point: Main Gate, Misawa Air Base For those without base access, please meet at 09:00 AM (JST) at Main Gate, Misawa AB. For those with base access, please meet at 09:30 AM (JST) at Main Gate, Misawa AB. Participants interested in attending the organized site visit shall email the Government POCs listed below by 29 April 2022, JST, with the following information: Participant Name Company Email Telephone Number If Base Escort Needed (Yes/No) - If escort is required, see paragraph 7 below Government POCs: Mr. David Flynn Email: David.W.Flynn.civ@usace.army.mil / Phone: 080-2201-0305 or DSN 226-4247 Mr. Ryan Marzetta Email: Ryan.J.Marzetta.civ@usace.army.mil Valid picture identification is required for entry into Misawa Air Base. Passport or Driver�s License are considered valid picture identification Transportation from Main Gate to site visit location will not be provided. No photographs are allowed on base except at the project site. Additional Requirements for Non-Base Pass Holders: Participants interested in attending the site visit who do not possess a Misawa AB base pass must also submit the below information, in addition to above requested information, to the point of contacts mentioned above by the above deadline.� i. Full name (Japanese and English) ii. Date of Birth iii. Passport/ID Number iv. Company name v. Nationality vi. Present address vii. Vehicle Make, Model, Color and license plate number viii. Copy of Vehicle Registration, Current Japanese Compulsory Insurance (JCI), Road Tax, and Liability Insurance. ****************************************************************************** SYSTEM FOR AWARD MANAGEMENT (SAM). �All interested companies shall be actively registered in the System for Award Management (SAM) database in order to be eligible for award of Government contracts. For a Joint Venture, the Joint Venture as an independent entity must be registered in SAM as such.� Information on registration and annual confirmation requirements may be found at http://www.sam.gov.� OFFEROR ELIGIBILITY.� Only local sources will be considered under this solicitation.� Local sources are sources (e.g. corporations, partnerships, or Joint Ventures [For a Joint Venture, the Joint Venture as an independent entity must satisfy the local source requirements or, in the alternative, each member of the Joint Venture must individually satisfy the local source requirements]) that are physically located in Japan and authorized (i.e. licensed and registered) to perform in Japan, the type of construction work specific in this solicitation.� Specifically, a prospective offeror must be duly authorized to operate and conduct business in Japan and�must fully comply with all applicable laws, decrees, labor standards, and regulations of Japan during the performance of the resulting�contracts.���In addition, prior to award of the contracts, offerors must be registered with the Government of Japan to do�construction work in Japan and possess necessary construction licenses and permits to perform work required under this�solicitation.� The U.S. Government will not offer �United States Official Contractor� status under Article XIV of the US-Japan Status of Forces Agreement (SOFA) to U.S. contractors normally resident in the United States; nor will the U.S. Government certify employees of such contractors as �Members of the Civilian Component� under Article I(b) of the SOFA.�
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/292613cccdf54c118345bbb1de0efb36/view)
 
Place of Performance
Address: JPN
Country: JPN
 
Record
SN06287955-F 20220405/220403230058 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.