SOLICITATION NOTICE
66 -- Circuit Breaker Test Set
- Notice Date
- 4/11/2022 1:25:30 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- NSWC PHILADELPHIA DIV PHILADELPHIA PA 19112-1403 USA
- ZIP Code
- 19112-1403
- Solicitation Number
- N6449822Q5051
- Response Due
- 4/18/2022 12:00:00 PM
- Archive Date
- 05/03/2022
- Point of Contact
- John M. Ngov, Jillian Randazzo
- E-Mail Address
-
john.m.ngov.civ@us.navy.mil, jillian.randazzo@navy.mil
(john.m.ngov.civ@us.navy.mil, jillian.randazzo@navy.mil)
- Description
- NSWCPD is trying to procure the following items below( Quantity, 1 each).� Items must be compatible with the Circuit Breaker Test Set.� Please see attached RFQ.��If you would be able to fulfill this requirement and are interested in submitting a quote, please do so via email by the closing date of APRIL 18, 2022. Include a signed copy of the RFQ and your quote on company letterhead.� If possible, please include with your quote a commercial Price List as well(or other documentations such as redacted past/current invoices of these or similar parts sold to customers other than the government for comparasion) to ensure theGovernment is receiving a fair and reasonable price for this procurement. PLEASE NOTE THE CHANGE IN SPECIFICATIONS REQUIRED FOR THE HIPOT METER BELOW. ALL OTHER ITEMS REMAINS THE SAME. If shipping is not included, please include an estimated shipping/transportationcosts for the following address: 1601 Langley Avenue Building 542 E Philadelphia, PA 19112 Please email if you have any questions or need additional information. TECHNIAL SPECIFICATION Circuit Breaker Test Set Input 480 V, 400 A, 60 Hz Output current 0 � 75000 Amp Automated Testing available Current meter accuracy 0.8% of reading and 0.3% of range. HCSS7 OUTPUT STAB ( REQUIRED FOR CONNECTION UNDER CIRCUIT BREAKER TEST) 0.5� (12.7 mm) thick blade 10.5� (266.7mm) long MICRO-OHM METER Input 100-240V, 50/60 Hz Resolution up to 0.1 �O Test Current (5 A - 200 A (True DC)) AC/DC HIPOT/MEGOHMMETERS NEW SPECIFICATIONS REQUIRED FOR THIS SECTION, PLEASE QUOTE ON THESE SPECS AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.00-20.0mA Output Frequency = 50/60Hz? DC Hipot Voltage Output = 0-6000VDC Leakage Current Limits = 1�A-7.500mA DC Ripple ? 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load Ground Continuity Current = DC 0.1A � 0.01A, fixed Resistance Limits = 0.0?-1.50? Insulation Resistance Voltage Output = 30-1000VDC Resistance Range = 1M?-5G? OLD SPECIFICATIONS IS BELOW, DO NOT QUOTE FOR THESE SPECS.� Input 100-240 VAC, 50/60 Hz Output 0.5 kV, 1 kV, 2.5 kV, 5 kV DC Insulation Resistance Values up to 10,000,000 Mega Ohm
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/bb9a6bb873e94893a618c9c340a203c9/view)
- Place of Performance
- Address: Philadelphia, PA 19112, USA
- Zip Code: 19112
- Country: USA
- Zip Code: 19112
- Record
- SN06294857-F 20220413/220412211321 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |