Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 17, 2022 SAM #7443
SOURCES SOUGHT

Y -- Manhattan Balance of Work VAMC Manhattan NY

Notice Date
4/15/2022 11:50:41 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F) WASHINGTON DC 20420 USA
 
ZIP Code
20420
 
Solicitation Number
36C10F22R0049
 
Response Due
5/2/2022 12:00:00 PM
 
Archive Date
07/31/2022
 
Point of Contact
Angeleque Batkins, Contracting Officer, Phone: 202-316-7313
 
E-Mail Address
angeleque.batkins@gmail.com
(angeleque.batkins@gmail.com)
 
Awardee
null
 
Description
Prospective Contractors: This is a Sources Sought Notice and is a preliminary notice for the RFP (Request for Proposal) for a Design-Bid-Build Construction Contract to construct the Manhattan Hurricane Sandy Recovery Program Balance of Work at the VAMC Manhattan Campus, NY. Project Description: VA has a requirement to construct the Manhattan VAMC, Hurricane Sandy Recovery Program Balance of Work at the VAMC Manhattan Campus of the VA NY Healthcare System as summarized herein and further defined in the future bid documents and General Requirements. All work is located on the campus of the fully operational Manhattan VA Medical Center at 423 E. 23rd Street, Manhattan, NY. The approximate period of performance is 5 years. The General Scope of Work (SOW) includes, but is not limited to, providing all labor, materials, and equipment for the following tasks per Construction Documents (CDs): Relocate all essential electrical equipment and systems prone to damage by flooding on the ground floor of Buildings 1, 2, 3 and 6 to the first floor to include interrupter switches, transformers, switchgear, and distribution branch circuit panel boards. Construct new elevated steel-frame generator platform with enclosure built on auger-cast piles to meet VA Physical Security Design Manual. Procure and install new generators and associated underground fuel tanks Construct steel frame electrical distribution substation vault for Building 1 on structural concrete mat slab and pile caps on existing structural pilings. Construct and complete electrical rooms on the first floor of Buildings 1 and 6. Complete electrical cutovers and tie-ins from existing building distribution system to new equipment in Substation 6 Make new electrical cutovers and tie-ins to new Substation 1 and generator platform equipment. Complete final renovations to ground floor to include updates to warehouse and loading dock, creation of office space, locker room and restroom facilities, egress corridor and updates of life-safety systems. Replace third floor kitchen walk-in refrigerators and freezers. Mitigate Asbestos Containing Material (ACM) and HazMat in interior and exterior construction areas. Remove contaminated soils and dewater and treated contaminated groundwater. Construct new in-ground lift-type security vehicle barrier. Install Variable Refrigerant Flow (VRF) HVAC system on the Ground Floor of Building 2 Add wet fire suppression protection system on the first and second floors of Building 2 Remove non-compliant door entering directly into a Stair from room 124A in Building 2. Stair #2 Complete installation of HVAC system at Telecom rooms TR-C, TR-D and TR-E. Build-out staff Locker Rooms, Break Room and Break Room Unisex Toilets within space of the existing switchgear room G502 Remove existing domestic water pumps in Room G0175S and install raised triplex pump skid. Build out new public Women s Toilet Room at the existing electrical / former fire command center room G383/0275N. Build out new Mechanical rooms in the Building Support and future Sim Lab and install HVAC systems for the Pharmacy Cache G951, Building Support G953, and shell space for the Future Sim Center G614 and Future Conference Center G613. Complete work at the under-side of Stair 1-1 to restrict VAMC s non-code compliant storage under an egress stair and install a 2-hour rated horizontal partition assembly to isolate the remaining systems that could not be relocated. Modify the existing GF2B area to correct life safety issues. These include the following: Corridor G113 unlevel landing / tripping hazard at egress door from Stair 121W. Corridor G113 wire mesh partition installation to prevent access to fall hazard at the air intake well to Mechanical Room G500A. Stair 1121W door swing with the revised direction of exit access. Stair 1121W partition demolition to remove an existing reduction in egress width violation. Shaft 715; replacement / installation of a rated door and associated hardware. Perform existing MRI electrical cut-over to Vault 6 Substation Provide electrical cutovers and relocate equipment for existing Hybrid OR. All construction work to be done according to approved Phasing Plan. Work activities will require off-hour working schedules including evenings and weekends based on hospital operations. Sources Sought Notice The project is anticipated to be a duration or 5 years from the Notice to Proceed. The project Magnitude is between $50,000,000.00 and $100,000,000.00. The North American Industry Classification System (NAICS) 236220, $36.5M (Commercial and Institutional Building Construction).  This source sought notice is for market research purposes in accordance with federal Acquisition Regulation (FAR) Part 10 and is to canvass firms classified under one or more of the following SBA programs: 8 (a), HUB Zone, SDV, WOSB, SDVOSB, and /or VOSB. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this source sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought. Firms interested in submitting their capabilities for this project must include the following information in the cover letter /introduction: (1) Company name, address, point of contact with phone number and e-mail address; (2) Business size determination, and qualifying small business status/certification of Small Business (3) Bonding capacity (from surety). If submitting as a Joint Venture (JV), all JV s must have an agreement, JV entity DUNS, and CVE certification. All SDVOSB firm submitting must provide their CVE certification with date of expiration. Please limit responses to (5) pages. The Contractor capability statement shall include, but not limited to: Design-Bid-Build Experience: Demonstrate previous experience performing similar type of government construction (before mentioned) with a value of at least $50,000,000.00 performed in the past five years. Demonstrate experience with Hospital, Medical Clinic, Healthcare facility construction experience, if not hospital or healthcare facility experiences demonstrate experience with institutional or administration buildings Capability to perform: Provide a construction management composition for similar type construction Briefly state how this project will be managed Respondents are requested to submit capability Statements that exhibit clear and convincing evidence of your firm s capabilities and experience to perform the stated project. Please submit capability packages via email to: Angeleque Batkins at angeleque.batkins@va.gov no later than 3:00pm ET on May 2, 2022, and in the subject line state Manhattan Balance of Work and [Company Name] . All information concerning this requirement will be posted only on the Contract Opportunities website (https://www.SAM.gov). At the current time no solicitation exists, therefore, DO NOT REQUEST A SOLICITATION package. All future notices related to this procurement will be posted on the Contract Opportunities website (https://www.SAM.gov) DISCLAIMER This Source Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/50b5e463d3684b18a3eb2962f510d2fc/view)
 
Place of Performance
Address: VAMC Manhattan Campus, New York VA NY Harbor Heathcare System 10010, USA
Zip Code: 10010
Country: USA
 
Record
SN06299912-F 20220417/220415230109 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.