SOURCES SOUGHT
66 -- PCR Thermal Cyclers and Laptop Brand Name or Equal to QuantStudio 6 Flex in support of VA Puget Sound Health Care System
- Notice Date
- 4/18/2022 1:23:56 PM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26022Q0415
- Response Due
- 4/26/2022 5:00:00 PM
- Archive Date
- 05/16/2022
- Point of Contact
- Jennifer Robles, Contract Specialist, Phone: 253-888-4923
- E-Mail Address
-
jennifer.robles1@va.gov
(jennifer.robles1@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following supplies in support of VA Puget Sound Health Care System (VAPSHCS) Seattle, Washington. VAPSHCS has a need for a real-time Thermal Cycler (also known as a Thermocycler, PCR Machine or DNA Amplifier) for the detection and quantification of DNA or RNA Brand Name or Equal to the Applied Biosystems QuantStudio 6 Flex Real-Time PCR System. Brand Name or Equal to: Part # Qty Description 4485691 1 QSTUDIO 6 FLX, 384W INST,LPTP 1 SYSTEM The Applied Biosystems QuantStudio 6 Flex Real-Time PCR System is a high-performance instrument designed to optimize research productivity. INCLUDES: QuantStudio 6 Flex Instrument Standard 384-Well Block, interchangeable Dell Laptop QuantStudio 6 and 7 Software Primer Express Software Installation Kit Packing Kit cUL (tested to CAN/CSA standards), UL, CE, C-TICK, WEEE compliant. LIMITED WARRANTY: One-year parts and labor (as provided in Applied Biosystems' written limited warranty statement and accompanying terms in the user manual or other product documentation). 4432470 1 2 4432470 384-WELL CALIBRATION INSTALL KIT 1 $2,255.00 $0.00 $0.00 3 4309849 FG,384-WELL CLEAR RXN PLATE EACH 1 $389.00 $0.00 $0.00 4 4311971 FG,OPTICAL ADHESIVE COVERS EACH 1 $285.00 $0.00 $0.00 5 4360954 OPTICAL ADHESIVE COVERS 25 PCS/ PACK 1 $89.50 $0.00 $0.00 6 4483285 384-WELL HARDSHELL PLATE CLEAR ,20 PCS PK MicroAmpr Endura Plate Optical 384-Well Clear Reaction Plate with Barcode, 0.02mL, 20 plates Applied Biosystems MicroAmpr EnduraPlateT plastic consumables offer excellent PCR or qPCR performance in formats developed to meet your experimental needs. All of our plastic consumables are validated with Applied 1 $181.00 $0.00 $0.00 Biosystems instruments for optimal fit and performance. With the new EnduraPlateT reaction plates, there is now a solution for work that requires special handling and an even greater degree of durability for use with multi-instrument experiments 7 TRN00076 TRN, QPCR FAS, 1 DAY Customer Site Please open a training call. 1 $3,480.00 $0.00 $0.00 9 4453543 96-WELL BLOCK UPGRADE EACH Standard 96-Well Block (0.2mL) upgrade for ViiA 7 Instrument. INCLUDES: ViiA 7 Std 96-well (0.2mL) Block Std 96-well (0.2mL) Heated Cover Std 96-well (0.2mL) Plate Adaptor Std 96-well (0.2mL) Tube Adaptor Storage Case for heated cover and plate adaptor Calibration Kit 1 $8,320.00 $0.00 $0.00 10 4432364 96-WELL ROI&BACKGROUND PLATES EACH 1 $262.00 $0.00 $0.00 11 4432382 TAQMAN RNASE P 96-WELL INSTR VERIF PLATE 1 $808.00 $0.00 $0.00 12 A26343 STD 96-WELL 10-DYE CAL KIT. EA 1 $978.00 $0.00 $0.00 13 TRN00130 INTRO TO HIGH RESOLUTION MELT 1 DAY Intro to High Resolution Melt (1 day).This course is designed for new as well as current users performing High Resolution Melt for SNP Genotyping, Methylation Studies and Mutation Screening who would like to learn more about the Complete Workflow Solutions offered by Life Technologies. 1 $3,685.00 $0.00 $0.00 14 ZGBASCQS TUDIO6FLE X ADDL BLOCK SERVICE,PM,QS6 ADD ON 1 $3,100.00 $0.00 $0.00 15 A46109 POWERTRACK SYBR MM, 5ML 5ML 1 $409.00 $0.00 $0.00 16 11756050 SUPERSCRIPT IV VILO MASTERMIX 50 RXNS 1 $672.00 $0.00 $0.00 17 4368814 KIT, HIGH CAPACITY CDNA RT (200 RXNS) The High-Capacity cDNA Reverse Transcription kit delivers extremely high-quality single-stranded cDNA from total RNA. 1 $380.00 $0.00 $0.00 18 4444557 TAQMAN FAST ADVANCED MMIX 5 ML 1 $508.00 $0.00 $0.00 19 4316567 FG,TUBE 8-STRING OPTICAL EACH 1 $136.00 $0.00 $0.00 20 4323032 FG,OPTICAL CAP (8 CAPS/ STRIPS) EACH 1 $141.00 $0.00 $0.00 21 4309849 FG,384-WELL CLEAR RXN PLATE EACH 1 $389.00 $0.00 $0.00 22 4360954 OPTICAL ADHESIVE COVERS 25 PCS/ PACK 1 $89.50 $0.00 $0.00 23 403012 TF,OPTICAL TRAY & CAPS (2000) EACH MicroAmp Optical 96-Well Reaction Plates and Optical Caps Includes MicroAmpr Optical 96-Well Reaction Plate with Barcode, 0.2mL. 20 plates MicroAmpr Optical 8-Cap Strip. 300 strips The MicroAmpr Optical 96-Well Reaction Plate with Barcode and Optical Caps is optimized to provide unmatched temperature accuracy and uniformity for fast, efficient PCR amplification The PCR instrument application requirement and specifications must have these capabilities: Genotyping and Haplotyping SNP, Mutation, Pathogen and Rare Allele detection Gene Expression, Protein Expression mRNA and miRNA Expression More than one user-interchangeable blocks to accommodate 96-well with 0.1 mL, 96-well with 0.2 mL, or 384-well plates. Can be upgraded to enable all additional functionality, including Applied Biosystems TaqMan Array Card compatibility, automation accessory compatibility, and 6 x 6 decoupled filters. Include a user-interchangeable and durable light source that is readily accessible and can be replaced easily. Can be used with 100 240 V outlets without modification or special plug requirements. Includes a heated lid assembly that heats the top of the sample plates and provides an effective seal to minimize evaporation of the reaction mixture. Instrument computers and software requirements: Must include a laptop that will be dedicated to the operation of and data processing on the PCR instrument. The software must be designed to collect and analyze the fluorescence data for the applications of absolute quantification, relative quantification, presence/absence assays, and allelic discrimination/single-nucleotide polymorphism (SNP) detection. The instrument software must allow both TaqMan and SYBR Green assay chemistries in the same run by collecting different filter colors for PCR vs. melt curve stages. Data must be compatible with Software from other QuantStudio Qualitative Real Time PCR instrument software systems. Vendor can provide computer system validation consulting services with flexible and comprehensive audit-style documentation packages that help users reduce risk and comply with regulations and standards. Vendor service and support: The instrument must have a warranty for a period of one year from the date of installation (or 15 months from the date of shipment whichever is earlier). The instrument purchase must include an orientation session by remote or in person by a trained technical scientist. The vendor must offer telephone technical support and field applications, sales, and service support to help resolve chemistry and instrumentation problems. Other information: The VAPSHCS lab has experience with the QuantStudio real-time PCR systems and have been collecting data with the QuantStudio real-time PCR systems. For continuity and data comparability the VAPSHCS lab must have a QuantStudio real-time PCR systems instrument and software or equal. VAPSHCS needs to perform genotyping and gene expression analysis on regular basis. VAPSHCS lab requires a qualitative real-time PCR system that will fit in and streamline daily laboratory operations. With interchangeable blocks That can detect differences in target quantity as small as 1.5-fold in single-plex reactions with a large linear dynamic range That has high number of excitation and emission filters that offer at least 21 different color combinations That allow a broad range of detection chemistries and maximum multiplexing quick installation With high efficiency and high throughput That has the flexibility to run multiple experiments simultaneously. No gray market or remanufactured items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM. Potential candidates having the capabilities necessary to provide the above stated supplies at a fair and reasonable price are invited to respond to this Sources Sought Notice via e-mail to Jennifer Robles at jennifer.robles1@va.gov no later than April 26, 2022, 5PM PST. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name, address, SAM Unique Entity Identifier and business size; point of contact name, phone number, and e-mail address; whether services are presently offered on a current GSA Federal Supply Schedule contract. NAICS Code 339113, Size Standard: 750 employees is applicable to determine business size standard. Any questions or concerns may also be directed via email to Jennifer Robles at jennifer.robles1@va.gov. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/683e71999ad84c57ad18301f2328a6a6/view)
- Place of Performance
- Address: Department of Veterans Affairs VA Puget Sound Health Care System Seattle Division 1660 South Columbian Way, Seattle, WA 98108-1532, USA
- Zip Code: 98108-1532
- Country: USA
- Zip Code: 98108-1532
- Record
- SN06301045-F 20220420/220418230057 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |