SOURCES SOUGHT
61 -- Generator (VA-22-00064636)
- Notice Date
- 4/25/2022 2:03:26 AM
- Notice Type
- Sources Sought
- NAICS
- 335311
— Power, Distribution, and Specialty Transformer Manufacturing
- Contracting Office
- 248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
- ZIP Code
- 33637
- Solicitation Number
- 36C24822Q0851
- Response Due
- 4/27/2022 7:00:00 AM
- Archive Date
- 05/27/2022
- Point of Contact
- Leonora Simmons, Contract Specialist, Phone: 813-972-7592
- E-Mail Address
-
leonora.simmons@va.gov
(leonora.simmons@va.gov)
- Awardee
- null
- Description
- SOURCES SOUGHT The Department of Veterans Affairs, James A, Haley Veterans Hospital (JAVH) located at 13000 Bruce B. Downs, Tampa, Fl. 33612 is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for Kohler 175REOZT4 with Kohler portable Paralleling Box Brand name only). The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 335311. Contractor shall provide equipment listed below: Manufactured by Kohler. Model #175REOZT4 Generator mounted on custom trailer with onboard DEC3500, Paralleling Box. Includes shipping, offloading, and startup) Also includes dual generator tracking system, qty 1. Startup to include factory warranty activation, 2-hour load bank test, and 2-hour parallel load bank (does not include fuel), qty 1. SPECIFIC NEED/ SALIENT CHARACTERISTIC S 5. 1. Minimum Trailer Characteristics Generator: (a) Must be 175REOZT4 (No alternatives are acceptable) (b) 139 kW/174 kVA (c) 60Hz, 120/208V, Wye, 3Ph, 4W (d) EPA Tier 4 compliant (e) ES Description 01 GPC Trailer 835190-11 (f) Literature Languages English (g) Engine 175REOZT4 Towable, 24V, 60Hz (h) Nameplate Rating Prime 125C Rise (i) Voltage 60Hz, 120/208V, Wye, 3Ph, 4W (j) Alternator 4S12X (k) Cooling System Unit Mounted Radiator, 45C (l) Skid and Mounting Skid/Tank, Mobile (m) Air Intake Heavy Duty (n) Controller DEC3500 (o) Selector Switch Selector Switch and Outlets (p) Connection Options Camlock Load Connectors (q) Enclosure Type Sound (r) Enclosure Material Steel (s) Starting Aids, Installed Cold Weather Package (t) Electrical Accy.,Installed Battery Charger, 6A (u) Fuel System Acc.,Installed Two Way Fuel Valve (v) Miscellaneous Accy,Installed Coolant in Genset (a) Warranty Standard (b) Quote must include offloading an startup. (c) Includes cables for paralleling with existing generators (d) Includes trailer mounted cable box (e) Includes GenTracker Monitoring System and 10 Output Relay Kit GM25951 Minimum Trailer Characteristics Paralleling Box: Must be DEC3500 Paralleling Box for compatibility with existing generator fleet. Must be mounted on trailer with generator. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. If your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. [Note: In accordance with FAR 10.001(b), agencies should not request potential sources to submit more than the minimum information necessary.] The government will evaluate market information to ascertain potential market capacity to 1) provide services consistent in scope and scale with those described in this notice and otherwise anticipated; 2) secure and apply the full range of corporate financial, human capital, and technical resources required to successfully perform similar requirements; 3) implement a successful project management plan that includes: compliance with tight program schedules; cost containment; meeting and tracking performance; hiring and retention of key personnel and risk mitigation. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 04/27/2022. All responses under this Sources Sought Notice must be emailed to leonora simmons@va.gov no later than 04/26/2022 at 10 am EST.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/266522ed1d4a4736860161ed2bde15aa/view)
- Place of Performance
- Address: James A. Haley VA Hospital 13000 Bruce B. Downs, Blvd., Tampa, FL 33612, USA
- Zip Code: 33612
- Country: USA
- Zip Code: 33612
- Record
- SN06307353-F 20220427/220425230103 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)