99 -- Liquid Helium (LHe) Recovery System

Notice Date
4/26/2022 11:51:03 AM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
ALLIANCE SUSTAINABLE ENRGY-DOECONTR Golden CO 80402 USA
 
ZIP Code
80402
 
Solicitation Number
SS-2022-Liquid_Helium_Recovery_System
 
Response Due
5/10/2022 4:00:00 PM
 
Archive Date
05/10/2022
 
Point of Contact
Rachel Province
 
E-Mail Address
Rachel.Province@nrel.gov
(Rachel.Province@nrel.gov)
 
Description
The Liquid Helium Recapture System must have the following capabilities: Liquid Helium Recapture: The recapture system ideally will recapture LHe that is boiling off super conducting NMR magnets as well as recapture LHe lost during transfers/fill of the magnets. The minimum recapture percentage will be greater than or equal to 70%. Ideally, the recapture would be closer to 90-95%. The volume of storage capability is unknown at this point as NREL has not yet settled on the pressure/size of the holding tanks. However, overall NREL would like the ability to hold the equivalent of ~100-150L of LHe. The pressure needs to be regulated in such a way that there won�t be damage to the magnet by backflow/backpressure. The system and components must be positioned in a way that stray magnetic fields don�t have an effect. Floor space within existing NMR Facility is approximately 6ft by 5ft with access to both power and chilled water. There is additional linear wall space near ceiling in at least two spots for capture balloon/bag. Liquification: Must have the ability to compress, purify and liquify gaseous helium for reuse. LHe needs to be stored in a castored dewar for ease of movement. Dewar itself is no larger than 100L. System should accommodate external helium gas. For example, other local universities/labs may capture helium and compress into 2,200 psi high pressure cylinders, ship to NREL, and request liquification into 60L or 100L dewars. LHe plant therefore must be capable of disconnecting from internal system and accepting external gas cylinders as source to be liquified.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/b7ba7b7e8c2f47f7a3f8652403ed1eda/view)
 
Place of Performance
Address: Golden, CO 80401, USA
Zip Code: 80401
Country: USA
 
Record
SN06308912-F 20220428/220426230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.