SOURCES SOUGHT
65 -- 580-22-3-167-0427 - Vidas III Analyzer (Instrument for Microbiology) (VA-22-00065924)
- Notice Date
- 4/28/2022 6:11:18 AM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- 256-NETWORK CONTRACT OFFICE 16 (36C256) RIDGELAND MS 39157 USA
- ZIP Code
- 39157
- Solicitation Number
- 36C25622Q0842
- Response Due
- 5/4/2022 8:00:00 AM
- Archive Date
- 05/14/2022
- Point of Contact
- Mr. Shannon L. West, Contract Specialist, Phone: 318-466-2086
- E-Mail Address
-
shannon.west1@va.gov
(shannon.west1@va.gov)
- Awardee
- null
- Description
- STATEMENT OF WORK SCOPE Contractor shall furnish all materials, parts, equipment, and tools for the below listed VIDAS III Analyzer for the Microbiology Laboratory at the Michael E DeBakey VA Medical Center, 2002 Holcombe Blvd, Houston, Texas 77030. All equipment shall be brand new, and all work shall be done in a first-class manner. The contract price shall be firm-fixed, all-inclusive not limited to specified products/equipment, installation, and setup/configuration. BACKGROUND The Microbiology Laboratory uses the Vidas III Analyzer to provide Procalcitonin (PCT) results as an aid in the risk assessment of critically ill patients for the progression to severe sepsis and septic shock. Additionally, the PCT result aids in decision making on antibiotic therapy for patients with suspected or confirmed lower respiratory tract infections such as community-acquired pneumonia, acute bronchitis, and acute exacerbation of chronic obstructive pulmonary disease in an inpatient setting and/or in the emergency department. It aids in the decision making on antibiotic discontinuation for patients with suspected or confirmed sepsis and it has been proven that PCT levels can increase quickly, specifically in patients with a serious bacterial infection. PCT is therefore an important marker enabling differentiation between bacterial infection and other causes of inflammatory reactions. REQUIREMENTS Microbiology Laboratory requires a VIDAS III Analyzer with the following part/product numbers, quantities, and requirements in order to perform various Microbiology testing: Part/Product Numbers Required Part/Product # Description Qty 4702895 VIDAS 3 Analyzer 1 27217 VITEKĀ® 2 Cart (48"") 1 4705103 Enhanced Warranty -VIDAS 3 1 Key Features Required Touch Screen Monitor LED Communication with an intuitive touch screen interface Bi-directional LIS connectivity 14-to-28-day calibration Humidity: 20-80% relative humidity (RH non-condensing) Test Security Fully automated pipettor action with single-use, disposable tips to avoid contamination Automated calibration and on-board dilution Traceability of all test components Integrated quality control management Continual Access Limited to no start up period Temperature-controlled loading bay 3 Separate racks each capable of containing 3 configurable segments that can hold a total of 27 samples, diluents and calibrators 4 independent compartments capable of each running 3 tests Capable of running 36 test per hour Management capability of emergency tests Broad Test Menu 100 tests in single-test format for the diagnosis of cardiovascular and infectious diseases, cancers, infertility, pregnancy and thyroiditis diseases On demand testing: 1 patient, 1 test, 1 result Ready to use reagents All components needed for a test must be included in the kit Rapid results: 17 to 120 minutes (time dependent upon test being performed) DELIVERY LOCATION: Microbiology Laboratory, Building 100, Room # 3A-122.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/22dea256ea6044c8ac2ccd4dbcc9f47f/view)
- Place of Performance
- Address: DEPARTMENT OF VETERAN AFFAIRS MICHAEL E DEBAKEY VA MEDICAL CENTER MEDVAMC 2002 Holcombe Blvd, Houston, TX 77030, USA
- Zip Code: 77030
- Country: USA
- Zip Code: 77030
- Record
- SN06311993-F 20220430/220428230108 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |