SPECIAL NOTICE
C -- 402-22-750 A/E Renovate Sterile Processing
- Notice Date
- 5/2/2022 9:10:33 AM
- Notice Type
- Special Notice
- NAICS
- 541330
— Engineering Services
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24122R0077
- Archive Date
- 07/31/2022
- Point of Contact
- Diane C. Davis, Contract Specialist, Phone: 207-623-8411
- E-Mail Address
-
diane.davis2@va.gov
(diane.davis2@va.gov)
- Awardee
- null
- Description
- Scope of Work: 402-22-750 VAME Togus ME Sterile Processing Department Renovation Project Summary: VAME Togus ME Sterile Processing Department (SPD) renovation consist of 8,400 GSF in building 200E on the first floor, and two dumbwaiters which transport SPD carts from/to the third floor Surgical Services. Please see Enclosure (1) for the location map. For the renovation no additional area is available. This is an upgrade of all parts of the space and services. Some of the systems and equipment shall be re-used as they are very new, also the dumb waiter locations shall not be changed. The air handling unit AH-6 is new, the AE firm to confirm capacity for use. The design of the SPD shall meet all VA SPD requirements including the Sterile Processing Service and Logistics Service Design Guide, and VA TIL requirements. The total product flow utilizing this GSF shall be determined and compared to the VA requirements. SPD Presently uses Centrak for temp/humidity monitoring. Users have indicated this is useful for trending data, but not ideal for alerting for out-of-range parameters; desire is to have display screen showing room pressure, temp, humidity, and issue live alarms for out-of-range parameters possible link to BMS to notify HVAC personnel. Spaces use ball in wall pressure indications and request continuation of the Ball in Wall indications as back up to the monitoring system. The Certification and Accreditation (C&A) requirements do not apply, and a Security Accreditation Package is not required. A/E shall coordinate with VA stakeholders to arrive at an optimal solution. During the renovation the SPD area must be vacated. This design must provide adequate temporary SPD services, Offices, Employee areas, Locker rooms, and environmentally controlled storage. Provide multiple proposals for the temporary spaces with Pros and Cons on each location, concepts to include transport times, and how to provide timely responses to surgery needs. At the end of the renovation all temporary areas must be returned to their original conditions.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/2e9124e10cad407080aa00d228209c45/view)
- Record
- SN06313620-F 20220504/220502230052 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |