SOURCES SOUGHT
65 -- Cerebral Oximeters Monitor System
- Notice Date
- 5/10/2022 12:39:01 PM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 256-NETWORK CONTRACT OFFICE 16 (36C256) RIDGELAND MS 39157 USA
- ZIP Code
- 39157
- Solicitation Number
- 36C25622Q0904
- Response Due
- 5/16/2022 5:00:00 AM
- Archive Date
- 05/19/2022
- Point of Contact
- William Shaver, Contract Specialist, Phone: 601-206-6953
- E-Mail Address
-
William.Shaver@va.gov
(William.Shaver@va.gov)
- Awardee
- null
- Description
- DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 REQUEST FOR INFORMATION 36C25622Q0904 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name products listed in the Performance Work Statement found in the background section below. In the response, please cite business size status. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large), proof that supplies are domestically made, proof that supplies are from a domestic small business if offeror is not the manufacturer, and unique entity identifier used in SAM.gov. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing these types of supplies. Please include the following: (a) Proof of OEM or OEM distributor of brand name supplies. (b) examples of prior completed Government contracts, references, and other related information. Please include contract number of previous contract(s). CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to William.Shaver@va.gov. Please respond to this RFI no later than 07:00 Central Standard Time on Monday, May 16, 2022. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. BACKGROUND: Performance Work Statement Background: We are requesting the purchase of a quantity of 3 each Medtronic INVOS PM7100 Cerebral Oximeters or equivalent. We are requesting these units because they are required by the VHSO Surgical Service for use during Orthopedic surgeries to monitor oxygen levels in patients. Scope: The Contractor will furnish all labor, transportation, parts, and expertise necessary to provide the VHSO with 3 each Cerebral Oximeters and the necessary training. Salient Characteristics for each Cerebral Oximeter Unit: The Monitor for each unit must feature a projective LCD multi-touch screen and must have at least 1280x800 pixel resolution. Monitor must include a Li-ion battery and AC power adapter. Monitor must feature a 3.0 USB and 2.0 USB in docking port. The docking station must have a DC in, USB 2.0 ports and VGA ports. A stand for each unit is required for mounting. The Preamplifier must include a preamplifier cable, a re-usable sensor cable, and a power cable. Power requirements for each unit must be 100V-240V with a 50Hz-60Hz input frequency. The battery for each unit must be capable of at least 1 hour of operating time and must be capable of recharging in 24 hours. Delivery Schedule: The requested equipment is required by 06/18/22 and will be delivered to the VHSO as soon as possible. The Contractor will ensure all deliverables are delivered to the following address: Veterans Healthcare System of the Ozarks, Warehouse Building 8, 1100 N. College Avenue, Fayetteville, AR 72703. Contractor Requirements: The Contractor shall not perform any service or provide any item that is outside the scope of work without the written approval of the Contracting Officer. Should the Contractor have to come to the VHSO for any reason other than delivery, the Contractor shall be required to log in with VA Police Dispatch (Building 1, first floor) upon arrival to obtain a contractor badge. The Contractor will always visibly wear the badge while on VHSO premises and will be required to turn in the badge before leaving VHSO premises. Item # Description/Part Number* Qty 1 PM7100-Monitor; Invos PM7100 Tablet 3 2 PMAC71DOC-Docking Station; INVOS 3 3 PMAC71STAND-Mount Stand; INVOS 3 4 PMPAMP71-Preamplifier; INVOS 71 3 5 PMAC71RSC-Sensor Cable; Reusable, INVOS 6 6 PT00059589-Power Cord; INVOS PM71, USA 3 DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/0a3de0fcf04f490c924378c5a1230aec/view)
- Place of Performance
- Address: Department of Veterans Affairs Veterans Healthcare System of the Ozarks Warehouse Building 8 1100 N. College Avenue, Fayetteville 72703
- Zip Code: 72703
- Zip Code: 72703
- Record
- SN06323309-F 20220512/220510230059 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)