Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 13, 2022 SAM #7469
SOURCES SOUGHT

43 -- ENCLOSED SELF PRIMING DUPLEX PUMPING STATION SYSTEM

Notice Date
5/11/2022 4:27:15 AM
 
Notice Type
Sources Sought
 
NAICS
33391 —
 
Contracting Office
DLA MARITIME - NORFOLK PORTSMOUTH VA 23709-5000 USA
 
ZIP Code
23709-5000
 
Solicitation Number
N4215820988066
 
Response Due
5/18/2022 6:00:00 AM
 
Point of Contact
Jessica Martin, Phone: 7573969953, Fax: 7573968119
 
E-Mail Address
jessica.gonzales@dla.mil
(jessica.gonzales@dla.mil)
 
Description
The Defense Logistics Agency (DLA) Maritime Norfolk Naval Shipyard is issuing this sources sought as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for the below items. Quantity of three (3) enclosed duplex pumping skids as described in the Scope of Work below. STATEMENT OF WORK NORFOLK NAVAL SHIPAYRD PORTSMOUTH, VA 23709 Requirement Owner: Austen McClelland, Code 900F.13, Building 299, 757-506-4734 The Vendor shall supply the following unit as specified: Qty 3 - TENCARV A Self-Priming Duplex Pumping System PIN TMC-DUP3796-4x4-30HPSHELTER Pumps: (2) Gould's Model 3796, Size 4x4-13, CD4mCu Duplex Stainless-Steel Construction, Solid 316 SST Shaft, John Crane 5600 Diamond Faced Cartridge Seal, C-Face Frame Adapter, Fabricated Steel C-Face Base, John Crane A-Series Coupling, Uni-Guard HDPE Machine Guard, I-Alert2 Bearing Condition Monitor. Motors: 30 HP TEFC Severe Duty Motors, 1800 RPM. 286TSC Frame, 3/60/460V. Control Panel: Duplex pump control panel for 30hp, 460v, hand-off-auto switches, hour meters, duplex alternator, high level alarm strobe and horn, horn silence pushbutton and (4) float switches. Separators: Rosedale model SEP-553 separator rated for 425 GPM @ 5 PSIG Differential. 316 SST Housing Construction, 4"" Pipe Size, 2"" Drain Purge Size. Enclosure: 8'x16'x8' Shelter Works ""Freedom Series"" Fiberglass shelter with 1.5"" thick polyiso insulation for R-12 thermal value. White gel coat interior, Grey exterior. Long walls will have a double door and one short wall facing the control panel will have a double door. Far wall will have piping extrusions. NEMA 4X junction box to power lighting, receptacle, 115V AC, 2250W heater with thermostat. Schedule 80 PVC conduit, wiring per NEC. (3) Weatherproof /LED 4' lights for interior, (2) weatherproof switches, (1) 18W Exterior down light with photocell. Minimum 90 mph ground level wind rating. Package and Piping: Galvanized Base, 316SS Pipe and fittings, Discharge isolation and check valves, Control panel mounted and wired, CAD approval drawing, Drain-lines installed for separators, Flow indicators for visual flow confirmation, Suction and Discharge lines/connection, PVC sch 80 Conduit, Suction and discharge gauge readings on exterior of enclosure, (1) 115V Meltric plug connection to power ancillary items such as lighting and temperature controls, (1) 460V Meltric plug to power pump controls/motors, Lifting lugs and forklift slots for transport. Additional Requirements: Shipping to POU {NNSY, Portsmouth, VA 23709). Delivery address is 1 Beaty Street, BLDG 276, Portsmouth, VA 23709.� The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 333911. This Sources Sought notice is for informational and planning purposes only and shall not be construed as an obligation or commitment by the Government. This notice is strictly for market research purposes. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposal(s) or quotation(s). The purpose of this notice is to obtain information regarding the capability and availability of qualified businesses that are interested in and have the available resources to support the execution of this potential requirement. The Government is not obligated to and will not assume financial responsibility for any costs incurred, nor will the Government pay for any information received from potential sources as a result of this notice. Submission of any information in response to this notice is purely voluntary. If your organization has the potential capacity and qualifications to provide these items or an equivalent, please provide the following information (at a minimum): Company Name Point of Contact Phone Number Email Address Cage Code Company Business Size Status Manufacturer (MFG) Information (if not the MFG) Manufacturer Business Size Status Statement of Capability Technical Information/Specifications Interested parties are encouraged to submit a response to this notice via email by 09:00 a.m. (EST) on May 18, 2022 and include NNSY- VIOP EQUIPMENT UPGRADE in the subject line. Please send responses and any questions concerning this opportunity directly to: Jessica Martin at Jessica.Gonzales@dla.mil.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c7c056f4413b41668e8426ee59c1ee7b/view)
 
Place of Performance
Address: Portsmouth, VA 23709, USA
Zip Code: 23709
Country: USA
 
Record
SN06324717-F 20220513/220511230106 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |