Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 15, 2022 SAM #7471
SOLICITATION NOTICE

J -- Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

Notice Date
5/13/2022 12:46:48 PM
 
Notice Type
Solicitation
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
W6QM MICC-JB LEWIS-MC CHORD JOINT BASE LEWIS MCCH WA 98433-9500 USA
 
ZIP Code
98433-9500
 
Solicitation Number
W911S822R0002
 
Response Due
5/23/2022 12:00:00 PM
 
Archive Date
07/30/2027
 
Point of Contact
Scott A. Byrd, Phone: 2534775435, Thomas R. Williams, Phone: 2539664371
 
E-Mail Address
scott.a.byrd.civ@mail.mil, usarmy.jblm.acc-micc.list.proposals@mail.mil
(scott.a.byrd.civ@mail.mil, usarmy.jblm.acc-micc.list.proposals@mail.mil)
 
Small Business Set-Aside
8A 8(a) Set-Aside (FAR 19.8)
 
Description
The Contractor shall provide all personnel, equipment, tools, materials, supervision, and personnel services necessary to examine, restore, maintain, repair, clean, inspect, and test the following: installed facility fire sprinkler systems, kitchen fire suppression systems, fire pumps, fire pump monitoring devices and related equipment, fire sprinkler monitoring devices, aircraft hangar Aqueous Film Forming Foam (AFFF) systems (to include annual lab testing of the foam concentrate agent), automatic fire alarms, Fire Alarm Control Panels (FACP) including the software and associated devices, (activation, warning and auxiliary), and electrical/electronic components of the systems. The Contractor shall provide testing and programming to facilities with Mass Notification Systems (MNS). The Contractor shall provide updated Computer-Aided Design (CAD) (current year) drawings in a manner that will�ensure fire systems serviceability and proper operation. Contractor shall provide a list of major component manufacturers and system components, year of installation as near as can be determined, as well as ITM cycle for sprinkler and suppression systems. Contractor shall submit reports to the Contracting Officers Representative (COR) at JBLM, Washington (WA) and leave a copy of the CAD drawing at the FACP in each building. All work shall comply with and be in accordance with (IAW) the Unified Facilities Criteria (UFC) 3-601-02 Operations and Maintenance: Inspection, Testing, and maintenance of Fire Protections Systems, National Fire Protection Association (NFPA) Standards 10 through 25, 70, 72, 96, JBLM requirements and the manufacturer�s instructions. The Unified Facilities Criteria (UFC) 3-601-02 shall take first precedence over other guidance. Technical Exhibit 1 (TE-1) shows the JBLM and YTC, WA facilities list.�Technical Exhibit 2 (TE-2) shows the Kitchen Hood Listing.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/4d1fc4ed3fbc4c50b08354ab561dd58e/view)
 
Place of Performance
Address: Joint Base Lewis McChord, WA 98433, USA
Zip Code: 98433
Country: USA
 
Record
SN06326599-F 20220515/220513230058 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.