Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 25, 2022 SAM #7481
SOLICITATION NOTICE

66 -- Automated Sample Preparation System

Notice Date
5/23/2022 10:15:48 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
FDA OFFICE OF ACQ GRANT SVCS Beltsville MD 20705 USA
 
ZIP Code
20705
 
Solicitation Number
75F40122Q112654
 
Response Due
5/24/2022 11:00:00 AM
 
Archive Date
06/08/2022
 
Point of Contact
Nick Sartain, Phone: 8705437370
 
E-Mail Address
nick.sartain@fda.hhs.gov
(nick.sartain@fda.hhs.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Amemdment 2 Questions and Answers. 1. Some general questions we would need to know in order to determine the best ultrasonicator for their lab. Response: This solicitation is NOT for an ultrsonicator.� An Ultrasonicator does not appear to meet the requirements specified in the solicitation. 2. Whats the application (NGS, Proteomics, Epigentics) ? Response: �The application would be strictly for the analysis of chloramphenicol and nitrofuran metabolites in aquaculture products. 3. How many samples are they processing on a weekly basis?� Response: On average, we process ~150 subsamples per week. ��� 4. What is their desired sample processing volume?� Response: The method has to be able to transfer 15 mL of the extract onto solid-phase cartridges.� Although we did not specify if that means a single transfer of 15 mL or if that means 15 transfers of 1 mL.� Either is technically acceptable; however, each additional��transfer adds both increased probability for error in the transfer and it adds additional time.� � � 5. Are they looking to integrate with a liquid handler?� Response: The whole solicitation is for a system that can transfer liquids.� The fundamental element of the equipment is it has to transfer liquid (15 mL) from a vessel onto a solid phase extraction cartridge, and then later elute the desired materials from that cartridge while unwanted materials are retained on the cartridge.� 6. Budget? Response: We don�t provide the budget. Other: For reference attached is the published method that this system is specifically being purchased for. Please note that the mention of trade names, commercial products, or organizations is for clarification purposes and should not be interpreted as an endorsement of a product or manufacturer.� The section below of the method might provide additional insight. Utilizing the ASPEC system, the HLB (3 cc _60 mg), solid-phase extraction cartridges were conditioned with 3mL of ethyl acetate, 3mL of methanol, and 3mL of water. The�ASPEC system loaded the samples onto the conditioned SPE cartridges and washed the cartridges with 2mL of water and 2mL of 30% methanol in water. Subsequently, the ASPEC system dried the SPE cartridges and eluted them with 3mL of ethyl acetate.� The quote due date is extended until May 24, 2022 at 1PM Central Time. No other questions will be answered. Amendment 1: This amendment provides answers to questions received. 1. What is the sample material? (i.e. Hydraulic cement) Response: The sample material is aquaculture tissue (i.e. shrimp, frog, fish, etc.) 2. What is the starting particle size of the material? (i.e. 3mm) Response: The tissue is ground with dry ice but is paste like once thawed. 3. What is the targeted final fineness? (i.e. 45um) Response: The tissue size doesn�t change.� The equipment in the solicitation should have the ability to transfer liquid from a vessel onto a solid-phase extraction cartridge described in the SOW. 4. What is the amount of sample to be processed in one sample batch? (i.e. 100mL) Response: The SOW stated it had to be able to do 20 samples� or more.� Each sample has 15mL that has to be transferred to the solid-phase extraction cartridge. 5. Are there any elements that will interfere with post-grind analysis? (i.e. Fe, Cr, etc.) Response: This is an organic testing analysis.� No metal elements are evaluated. See attached combined synopsis/solicitation.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2bf8d1408a894bec99c42f268eb6b0aa/view)
 
Place of Performance
Address: Jefferson, AR 72079, USA
Zip Code: 72079
Country: USA
 
Record
SN06335700-F 20220525/220523230104 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.