SOURCES SOUGHT
65 -- Equipment Steam Sterilizer
- Notice Date
- 6/3/2022 10:24:24 AM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26022Q0553
- Response Due
- 6/17/2022 5:00:00 PM
- Archive Date
- 08/16/2022
- Point of Contact
- Jeffrey Hansen, Contract Specialist
- E-Mail Address
-
jeffrey.hansen2@va.gov
(jeffrey.hansen2@va.gov)
- Awardee
- null
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following supply: Steam Sanitizer for the Southern Oregon Rehabilitation Center and Clinic in White City Oregon. The Contractor shall furnish all necessary labor, supervision, materials, supplies, tools, equipment and transportation to perform installation of this supply in accordance with the specifications outlined in this contract. A steam sterilizer that will fit the following working area dimensions; Width: 30 , Height: 75 , Depth: 46 . The power supply needed to properly operate the steam sterilizer are as follows: Electrical Controls: 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp, Electrical Vacuum Pump Option: 208 Volt, 50/60 Hz, 3-phase, 6 Amps, 240 Volt, 50/60 Hz, 3-phase, 6 Amps or, 480 Volt, 50/60 Hz, 3-phase, 3.2 Amps. Minimum plumbing fixtures required for the steam sterilizer are as follows; Steam Line: ½"" NPT, 50 to 80 psig, dynamic, 97 to 100% vapor quality, Drain Lines: 1½"" ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to Engineering Data.) Sterilizer Feed Water: 1"" NPT: 30 to 50 psig for water ejector, 20 to 50 psig for vacuum pump or, 40 to 50 psig for SFPP sterilizers. Steam sterilizer will need features capable properly sterilizing Reusable Medical Equipment; i.e. Pre-Vac, Gravity, etc. to meet the various department needs in supplying Reusable Medical Equipment to the end user. Steam sterilizer will need to be easy to use and integrate into the current workflow of the assembly area. Potential candidates having the capabilities necessary to provide the above stated equipment with installation are invited to respond to this Sources Sought Notice via e-mail to Jeffrey Hansen at jeffrey.hansen2@va.gov no later than 10 June 2022, 5 PM Pacific. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, and e-mail address; capability statement and if the services are available on a current GSA Federal Supply Schedule contract. NAICS Code 339113 is applicable to determine business size standard. Any questions or concerns may also be directed to Jeffrey Hansen via e-mail. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/aa9d741c353a4262bdaf45ae9b1adcfc/view)
- Place of Performance
- Address: White City VA Rehabilitation Center and Clinics 8495 Crater Lake Hwy, White City 97503
- Zip Code: 97503
- Zip Code: 97503
- Record
- SN06347681-F 20220605/220603230101 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |