SOURCES SOUGHT
99 -- ATIP RFI DC Disconnects and AC Disconnects
- Notice Date
- 6/14/2022 7:38:58 AM
- Notice Type
- Sources Sought
- NAICS
- 541715
— Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- Contracting Office
- FLUOR MARINE PROPULSION - DOE CONTRACTOR Schenectady NY 12301 USA
- ZIP Code
- 12301
- Solicitation Number
- FMP-NNL-0019
- Response Due
- 7/11/2022 2:00:00 PM
- Point of Contact
- Anne Roth, Phone: 412-476-6572, Engers Davance Mercedes, Phone: 518-612-5118
- E-Mail Address
-
ATIP@unnpp.gov, engers.davance-mercedes@unnpp.gov
(ATIP@unnpp.gov, engers.davance-mercedes@unnpp.gov)
- Description
- THIS IS A REQUEST FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION. This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL) is utilizing this request for information for market research to determine what vendors have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information. � � NNL is issuing this request for information to identify sources capable of providing dc isolation and ac isolation technologies that can support the following goals: DC Isolation for the following scenarios � Handle continuous 450 amps at 1,000 vdc Manually operated. Handle 1,000 interrupting cycles at 50 amps and 1,000 vdc. Handle 10 interrupting cycles at full load of 450 amps at 1,000 vdc. Handle transient of 800 amps at 1,000 vdc for 20 seconds. Handle transient of 1,500 amps at 1000 vdc for 1 second. Space envelope smaller than 10 inches X 4 inches X 10 inches. Handle continuous 1,000 amps at 425 vdc Manually operated. Handle 1,000 interrupting cycles at 50 amps and 425 vdc. Handle 10 interrupting cycles at full load of 1,000 amps at 425 vdc. Handle transient of 1,700 amps at 425 vdc for 20 seconds. Handle transient of 2,400 amps at 425 vdc for 1 second. Space envelope smaller than 10 inches X 4 inches X 10 inches. AC Isolation for the following scenarios � Handle continuous 700 amps at 600 vac Manually operated. Handle 1,000 interrupting cycles at 50 amps and 600 vac. Handle 10 interrupting cycles at full load of 700 amps at 600 vac. Handle transient of 1,300 amps at 600 vac for 20 seconds. Space envelope smaller than 10 inches X 4 inches X 10 inches. Responses to this request are due July 11, 2021
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/8d3f26a59e1e49028f9d644a5f415e5a/view)
- Place of Performance
- Address: USA
- Country: USA
- Country: USA
- Record
- SN06358345-F 20220616/220614230119 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |