Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 29, 2022 SAM #7516
SOLICITATION NOTICE

45 -- Heat Cable

Notice Date
6/27/2022 7:58:33 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333414 — Heating Equipment (except Warm Air Furnaces) Manufacturing
 
Contracting Office
NORFOLK NAVAL SHIPYARD GF PORTSMOUTH VA 23709-1001 USA
 
ZIP Code
23709-1001
 
Solicitation Number
N4215822QE063
 
Response Due
7/1/2022 9:00:00 AM
 
Archive Date
07/16/2022
 
Point of Contact
ALESHA RAY, Phone: 7573968672, Chad R. Godwin, Phone: 7576361309
 
E-Mail Address
alesha.j.ray.civ@us.navy.mil, chad.godwin@navy.mil
(alesha.j.ray.civ@us.navy.mil, chad.godwin@navy.mil)
 
Description
This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the information in FAR Subpart 12.6, using Simplified Acquisition Procedures for commercial items found at FAR 13.5, as supplemented with additional information included in this notice.� This announcement constitutes the only solicitation; a written solicitation will be issued.� The RFQ number is N42158-22-Q-E063.� It is the responsibility of the contractor to be familiar with the applicable clauses and provisions.� The clauses may be accessed in full text at these addresses:� FAR Clauses:� https://acquisition.gov DFARS Clauses:� https://www.acq.osd.mil/dpap/dars/dfarspgi/current/index.html DASN(P) site: https://www.secnav.navy.mil/rda/DASN-P/Pages/NMCARS.aspx. The Services Contract Division, C410, Norfolk Naval Shipyard (NNSY), Portsmouth, VA intends to award a Firm Fixed-Price contract on the following item: HEAT TRACING STRIP, CABLE,� 10 WATT, SELF REGULATING: SHALL OPERATE WITH 115/120 VOLTS AC, 60 CYCLES, SINGLE PHASE. HEAT OUTPUT SHALL BE 10 WATTS PER FOOT AT 50 DEGREES F. MUST BE A FLAT, RIBBON TYPE, TAPE, WITH A MAXIMUM WIDTH OF 1/2 INCH ACROSS OUTER JACKET. BUSS WIRES SHALL BE A MINIMUM 16 A.W.G. COPPER OR COATED COPPER WIRE.MUST HAVE A SHIELD OVER THE INNER JACKET MADE OF COPPER OR TINNED COPPER BRAID, 14 A.W.G. EQUIVALENT. MUST HAVE AN OUTER JACKET OF POLYOLEFIN OR POLYOLEFIN MODIFIED TO MEET THE REQUIREMENTS OF THIS SPECIFICATION AND HAVE A MINIMUM THICKNESS OF .010 INCH. BOTH INNER AND OUTER JACKETS MUST BE CONTINUOUS WITHOUT NICKS, CUTS, OR CRACKS WHICH EXPOSE THE HEATING CORE.SELF-REGULATING HEATING CORE MUST HAVE A POSITIVE TEMPERATURE COEFICIENT WHICH CAUSES ITS RESISTANCE TO INCREASE WITH AN INCREASE IN TEMPERATURE. MUST BE CAPABLE OF REGULATING AND MAINTAINING A MINIMUM OF 250 LINEAR FEET OF TAPE AT A CONSTANT TEMPERATURE.MUST BE CAPABLE OF BEING FIELD-CUT TO LENGTH AT ANY POINT WITHOUT CREATING COLD SPOTS.MUST BE CAPABLE OF BEING OVERLAPPED OR CROSSED AT ALL POWER OUTLETS WITHOUT DAMAGE TO THE HEATER. SHALL NOT EXCEED 160 DEGREES F WHEN INSTALLED ANY AMBIENT TEMPERATURE MUST BE SUITABLE FOR HEAVY INDUSTRIAL APPLICATION IN AN OUTDOOR MARINE ENVIRONMENT. JACKETS MUST BE WATERTIGHT. TAPE MUST BE CAPABLE OF BEING BENT A MINIMUM OF 180 DEGREES IN A 1-INCH RADIUS AT 10 DEGREES F WITHOUT CRACKING THE INSULATION. RESISTANCE OF THE INNER AND OUTER JACKETS MUST BE A MINIMUM OF 400 MEGOHMS PER 1000 LINEAR FEET AFTER THE TAPE HAS BEEN IMMERSED IN WATER FOR A MINIMUM OF 24 HOURS. MUST BE CAPABLE OF WITHSTANDING A 2500 VOLT DIELECTRIC TEST FOR A MINIMUM DURATION OF 1 MINUTE AFTER ALL BEND TESTS, ALL WATER IMMERSION TESTS, AND ALL AGING TESTS HAVE BEEN COMPLETED. MERCURY FREE CLAUSE INVOKED. CERTIFICATE OF COMPLIANCE CLAUSE INVOKED. The NAICS code is 333414 and the Small Business Standard is 500 employees. The proposed contract is to be solicited as Unrestricted.� FOB Destination applies.� Responsibility and Inspection:� unless otherwise specified in the order, the supplier is responsible for the performance of all inspection requirements and quality control.� � All responsible sources may submit a quotation which will be considered by the Government. By submitting a quotation, the vendor will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency.� Failure to do so may represent grounds for refusing to accept the quotation.� The Contracting Officer reserves the right to conduct verbal or written discussions with respect to other than price with the vendors at any time prior to award.� By submission of a quotation, the vendor acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the solicitation, except for awards to foreign vendors for work to be performed outside the United States.� Lack of registration in SAM database will make a vendor ineligible for award.� Vendors may obtain information on registration and annual confirmation requirements by visiting https://www.sam.gov.� Please direct questions regarding this requirement to Alesha Ray at alesha.j.ray.civ@us.navy.mil.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/30fb65859df84919b4a6d305eb2fabf2/view)
 
Place of Performance
Address: Portsmouth, VA 23709, USA
Zip Code: 23709
Country: USA
 
Record
SN06370361-F 20220629/220627230101 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.