Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 29, 2022 SAM #7516
SOURCES SOUGHT

66 -- Source Sought Notice

Notice Date
6/27/2022 10:48:55 AM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
RPO EAST (36C24E) PITTSBURGH PA 15212 USA
 
ZIP Code
15212
 
Solicitation Number
36C24E22Q0168
 
Response Due
6/28/2022 9:00:00 AM
 
Archive Date
07/28/2022
 
Point of Contact
Rachael Talbott, Contract Specialist
 
E-Mail Address
rachael.talbott@va.gov
(rachael.talbott@va.gov)
 
Awardee
null
 
Description
Summary: This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.  This Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available products and services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought.    The Veterans Health Administration (VHA) is seeking a vendor to provide the following products and/or services below. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.  The Department of Veterans Affairs, Atlanta VA Medical Center, is in need of a Leica CM1950 Config. 4 US needed for sectioning frozen tissues for immunocytochemistry chemistry and analysis.   Technical Specifications/ salient characteristics The configuration includes object head cooling, which is required for sectioning transplanted cells into the eye, and includes UV disinfection which aids in safety when working with human tissues. The Leica CM1950 basic instrument is equipped with CryoZone technology, and encapsulated microtome with specimen orientation. The instrument can be ordered with various options including actively cooled object head (dual compressor,) motorized sectioning drive, vacuum section waste removal system, and a wide range of accessories. Microtome Section thickness range 1 to 100 m Trimming thickness range Set at 10 to 40 m or 1 to 600 m Horizontal specimen feed 25 mm + 1 mm Vertical specimen stroke 59 mm ± 0.5 mm Specimen retraction 20 m (can be deactivated) Maximum specimen size 50 x 80 mm Specimen orientation ±8 ° (x-, y-axis) Coarse feed Slow: 300 m/s; Fast: 900 m/s Cryochamber Temperature range 0 °C to -35 °C ±5 K, adjustable in 1 K increments, at ambient temperature of 20 °C Cooling time to -25 °C approx. 5 h at 20 °C ambient temperature Defrosting Automatic or manual hot gas defrost, 1 automatic defrost cycle/24 hours, time-controlled (duration 12 min.) Quick-freeze shelf Minimum temperature Minimum temperature -42 °C (±5 K), at chamber temp. -35 °C (+5 K) Number of freezing stations 15+2 Defrosting Manual hot gas defrost Peltier element Max. Temperature difference -17 K, at chamber temperature of -35 °C +5 K Number of freezing stations 2 Dimensions and weights Width (w/o handwheel) 700 mm Width (with handwheel 835 mm Depth 850 mm Height 1215 mm Working height (armrest) 1025 mm Weight without accessories 145 kg - 193 kg, depending on configuration Options Object head cooling optional, operated with separate compressor Temperature range -10 to -50 °C ± 3 K Defrosting Manual electrical heater defrost 5. Delivery:  Department of Veterans Affairs, Nashville University of Vanderbilt 2215 Garland Avenue Nashville, TN 37232    6. Installation:   Installation and demonstration are required.    7. Information Technology:  No additional IT support requirements are needed for this equipment.    RESPONSE COMMITMENT    I. Response:    A. Capability statement and with general understanding of the industry and current knowledge and subcontract networks that would be used to support the requirement as identified herein. Provide small business information for your company and any subcontractors.   B. Submittals furnished will not be returned to the sender. No debriefs will be conducted. Eligibility in participating in a future acquisition does not depend upon a response to this notice.    II. Timeline:   A. This request will close on stated date within the Government Point of Entry (GPE).    Notes:   This Sources Sought is for planning purposes only to gain knowledge of potential qualified sources and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 3345164. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. This notice is not a request for competitive proposals; however, any responsible source who believes it is capable of meeting the requirement and who is the Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller of all the items listed above, may submit a capability statement to the contracting office than no later than Thursday, June 30, 2022, 12:00 PM EST. Interest/capability statements may be sent to Rachael Talbott Rachael.Talbott@va.gov. No telephone responses will be accepted.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2e0322fee62e4e1a9fbd247c3e33dfc6/view)
 
Place of Performance
Address: Department of Veterans Affairs, Nashville University of Vanderbilt 2215 Garland Avenue, Nashville, TN 37232, USA
Zip Code: 37232
Country: USA
 
Record
SN06370802-F 20220629/220627230104 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.